O2 analysis

Set Descending Direction
Page:
  1. 1
  2. 2
  • TriOxmatic® 700 sensor

    €0.00
    • body material:1.4571/POM
    • protection class:IP68
    • range:0.0 ÷ 60.0 mg/l
    • accuracy:± 1%
    • other:SensLeck, SenReg function
    • pressure:10bar
    • application:water, waste water
  • ESS 700 VA/N socket

    €0.00
    • temperature:0 ÷ 50°C
    • pressure:3bar
    • dimensions:ø60mm x 142mm
    • application:650/690/700(IQ)/701(IQ) and FDO sensors mounting into the pipe
    • case material:PVC/POM
    • set includes:45° PVC T-piece (d 63 DN 50), O-ring seals and union nut
  • EH/W 170 mounting accessory

    €0.00
    • body material:1.4571
    • application:electrode fixture assembly for direct wall mounting of UA armatures and sensors of series 650/690/70X and 70X IQ
  • EH/U 170, EH2/U 170, EH3/U 170 holder

    €0.00
    • application:up to 3 sensor holder for direct mounting of series 650/690/70X and 70X IQ sensors to a swing mounting assembly
    • material:stainless st. / POM
  • EH/P170 mounting accessory

    €0.00
    • application:pendulum mounting assembly for installation of on-line sensors with Ø40mm shaft into the channels
    • set includes:4m chain from plastic, 1.5m tube (1.4301), tube fixator
  • EH/F mounting accessory

    €0.00
    • application:for installation of on-line sensors with 40 mm shaftØ into the tank
    • set includes:4m chain from plastic, 1.5m tube (1.4301), tube fixator
  • DIQ/S 182 controller

    €0.00
    • protection class:IP66
    • output:4 x AO (4 ÷ 20 mA), 5 x RO
    • temperature:-20 ÷ 55°C
    • other:protection from overvoltage
    • input:up to 2 x IQ sensors
    • communications:Profibus DP, ModBus
  • DIQ/S 182 XT-4 controller

    €0.00
    • protection class:IP66
    • output:5 x AO(4÷ 20mA), 6 x RO
    • temperature:-20 ÷ 55°C
    • other:protection from overvoltage
    • input:up to 4 x IQ sensors
    • communications:Profibus DP, ModBus, GSM
  • 2020XT controller

    €0.00
    • protection class:IP66
    • output:IO, RO (unlimited)
    • temperature:-20 ÷ 55°C
    • input:up to 20 x IQ sensors
    • communications:Profibus, ModBus, RS232, GSM
    • memory:525600 (data packages)
  • ESS 700 VA/10 socket

    €0.00
    • temperature:0 ÷ 60°C
    • pressure:10bar
    • dimensions:ø60mm x 142mm
    • application:weld-in socket for mounting in pipes
    • case material:1.4571
  • D700/N and D702/N flow-thru vessels

    €0.00
    • body material:D700/N: PVC, D702/N: 1.4571
    • pressure:<1bar
    • application:for 650/690/700/701 (IQ) and FDO sensors mounting into the process
    • capacity:2 ÷ 7l/min (30l/min)
  • EBST 700-DU/N EBS 700-DU/N

    €0.00
    • body material:PVC/POM
    • temperature:0 ÷ 50°C
    • pressure:3bar
    • application:650/690/700(IQ)/701(IQ) and FDO sensors mounting into the pipe
    • set includes:45° PVC T-piece (d 63 DN 50), O-ring seals and union nut
Set Descending Direction
Page:
  1. 1
  2. 2