Ordering code |
Manufacturer |
Item description |
List Price [EUR/piece] |
104100 |
Xylem WTW |
pH combination electrode with gel electrolyte, S7 plug head, glass-shaft; PG 13.5 screw thread |
275 |
104150 |
Xylem WTW |
ORP combination electrode with gel electrolyte, S7 plug head, glass-shaft; PG 13.5 screw thread |
238 |
104151 |
Xylem WTW |
Temperature sensor Pt 1000 for transmitter Multiline 1000 and pH 298 ph Pt1000; open cable ends. |
160 |
108150 |
Xylem WTW |
Cable ORP/pH, S7 connector, 1 m (3.3 ft), included in pre-assembled panel MULTILINE 1000 |
43 |
108152 |
Xylem WTW |
4-wire connection cable (1m/3.3 ft) for chlorine electrodes FCML 412-S, FCML 68-S, TCML-S for connection to the transmitter CL 7010. |
73 |
108153 |
Xylem WTW |
2-wired cable to connect the chlorine sensors FCML 68/412 (N) and TCML (N) to the controllers Cl 298 and Multiline 1000, 5m. When ordering a drinking water panel, the cable does not need to be ordered separately. |
27.1 |
108154 |
Xylem WTW |
Cable for anaolg controllers of series 298 to export logged data via USB. |
134 |
201150 |
Xylem WTW |
Flow-thru armature for chlorine sensors FCML 68/412 (N) and TCML (N). 1 sensor mountable, DN 15. |
290 |
201187 |
Xylem WTW |
pH independent chlorine sensor FCML 412 N, electrochemical measurement, appropriate for the online measurement of free chlorine in drinking water and swimming pools. Range: 0-2 mg/l; pH range 4–9 |
1598 |
201188 |
Xylem WTW |
Electrode for free chlorine according to electrochemical principle. For measuring in drinking water and swimming pools. Range: 0.05 - 20 mg/l, pH range 4 - 9 |
1598 |
201192 |
Xylem WTW |
Chlorine sensor TCML N, electrochemical measurement, appropriate for the online measurement of total chlorine in drinking water and swimming pools. Range: 0-2 mg/l |
1598 |
201193 |
Xylem WTW |
TCML N-S electrode for total chlorine according to electrochemical principle. For measuring in drinking and pool water. Range: 0.05 - 10 mg/l; pH range 4 - 12 |
1598 |
201931 |
Xylem WTW |
Electrochemical D.O. sensor with 1 m (3.3 ft) fixed cable for measuring and controlling oxygen in drinking water. Use with transmitter MULTILINE 1000 or Oxi 4000. Range: 0-20 mg/l or 0 - 200%, temperature range: -5–45 °C, with temperature sensor Pt 1000; open cable ends. |
796 |
202300 |
Xylem WTW |
Maintenance kit for oxygen electrode Oxi ML 41. Includes 3 pcs. replacement membranes and 6 vials electrolyte. |
185 |
205245 |
Xylem WTW |
Maintenance kit for chlorine sensor TCML N(-S). Includes 100 ml electrolyte and 1 replacement membrane. |
196 |
205246 |
Xylem WTW |
Maintenance kit for chlorine sensor FCML 412 N(-S): Includes 100 ml electrolyte and 1 replacement membrane. |
185 |
205247 |
Xylem WTW |
Maintenance kit for chlorine sensor FCML 412. Includes 100 ml electrolyte and 1 replacement membrane. |
185 |
205248 |
Xylem WTW |
Maintenance kit for chlorine sensor FCML 68. Includes 100 ml electrolyte and 1 replacement membrane. |
185 |
205249 |
Xylem WTW |
Maintenance kit for chlorine sensor TCML(-S). Includes 100 ml electrolyte and 1 replacement membrane. |
196 |
290051 |
Xylem WTW |
Internal measuring module for chlorine (board mountable into MULTILINE 1000) |
624 |
291234 |
Xylem WTW |
Monitor for direct connection of analogue oxygen sensors, with 2 analog and relay outputs, Modbus,115V/230V and Pt1000 |
1380 |
301150 |
Xylem WTW |
Conductivity cell, with 1 m fixed cable, 2 graphite electrodes; – 5–80°C; range 100 µS/cm - 20 mS/cm; temperature measurement with Pt 1000, PG 13.5 screw thread |
352 |
390026 |
Xylem WTW |
Internal measuring module for conductivity (board mountable into MULTILINE 1000) |
624 |
391234 |
Xylem WTW |
Monitor for direct connection of analogue conductivity measuring cells, with 2 analog and relay outputs, Modbus, 115V/230V and Pt1000 |
1444 |
401993 |
Xylem WTW |
Angular flow thru armature for conductivity and oxygen sensors with PG 13.5 screw thread. Material: PVC. |
401 |
401995 |
Xylem WTW |
Flow thru armature for pH, conductivity and ORP sensors with PG 13.5 screw thread. Material: PVC |
459 |
480200 |
Xylem WTW |
Multiparameter transmitter for up to 16 sensors (pH/ORP, conductivity, temperatur, turbidity, free and total chlorine, dissolved oxygen), Touch-Screen, digital communication interface (Modbus/RS 485), internal logger (up to 50.000 entries incl. Date and time), 16 inputs (4 interal, 12 external), 4 virtual channels, can be equipped with: 4 external current outputs (0/4–20 mA), 4 internal relays, languages: german, english, chinese; power supply 230 VAC |
3846 |
480201 |
Xylem WTW |
Multiparameter transmitter for up to 16 sensors (pH/ORP, conductivity, temperatur, turbidity, free and total chlorine, dissolved oxygen), Touch-Screen, digital communication interface (Modbus/RS 485), internal logger (up to 50.000 entries incl. Date and time), 16 inputs (4 interal, 12 external), 4 virtual channels, can be equipped with: 4 external current outputs (0/4–20 mA), 4 internal relays, languages: german, english, chinese; power supply 115 VAC |
3846 |
480265 |
Xylem WTW |
Flow meter with frequency output, PVC, DN10 |
211 |
600026 |
Xylem WTW |
Online turbidity meter Turb PLUS 2020 with white light, nephelometric, with ultrasonic cleaning system; Specifications meet US EPA 180.1; Preconfigured range 0–100 FNU / NTU (±2% or ±0,02 NTU under 40 NTU); changeable by customers to 0-10 or 0-1000; Integrated bubble rejection system; Outputs: current 4–20 mA and RS 485 (Modbus); Scratch-resistant borosilicate glas cuvette. 110–240 VAC |
4322 |
600036 |
Xylem WTW |
Online turbidity meter Turb PLUS 2120 with infrared light, nephelometric, with ultrasonic cleaning system; Specifications meet ISO EN DIN 7027; preconfigured measuring range 0–100 FNU / NTU (±2% or ±0,02 NTU under 40 NTU); changeable by customers to 0-10 or 0-1000; Integrated bubble rejection system; Outputs: current 4–20 mA and RS 485 (Modbus); Scratch-resistant borosilicate glass cuvette, 110–240 VAC |
4504 |
600037 |
Xylem WTW |
Online Turbiditymeter-Set; Additional Bubble trap included; Mesurement with Infraredlight, nephelometric; Specifications meet DIN EN ISO 7027; preconfigured measuring range 0 - 100 FNU / NTU (± 2% / 0,02 NTU iunder 40 NTU); Outputs: current 0/4-20 mA and RS 485 (Modbus); Cuvette: scratch-resistant Borosilicate Glass; Turbidimeter TURB PLUS 2120 with integrated cuvette and hoses, standards need to be ordered separately; |
4644 |
600041 |
Xylem WTW |
Bubble rejection system for online turbidity meters Turb 2000 - Turb 2120 |
795 |
600046 |
Xylem WTW |
3 flow through cuvettes for online turbidity meters of TURB 2000 series without ultrasonic cleaning system |
75 |
600047 |
Xylem WTW |
1 flow through cuvette for online turbidity meters of TURB 2000 series with ultrasonic cleaning system |
303 |
600048 |
Xylem WTW |
1 replacement desiccant tray for online turbidity meters Turb 2000 - Turb 2120 |
82 |
600049 |
Xylem WTW |
Tubing Kit (tubings, fittings, clamps, back pressure valve) online turbidity meters Turb 2000 - Turb 2120 |
378 |
600050 |
Xylem WTW |
Flow through unit for online turbidity meters Turb 2000 - Turb 2120 |
322 |
600052 |
Xylem WTW |
Calibration standard set for online turbidity meters Turb 2000 - Turb 2120 (excluding Turb 2110); Standards 0.02, 10 and 1000 NTU; cleaning tissues and designation rings. Acc. To EN ISO 7027 (secondary) and US EPA (Primary standard) |
361 |
600054 |
Xylem WTW |
Calibration standard set for online turbidity meters Turb PLUS 2000 Standards 0.02, 10 and 100 NTU; cleaning tissues and designation rings. Acc. to DIN EN ISO 7027 (secondary) and US EPA (Primary standard). |
361 |
600056 |
Xylem WTW |
Calibration Kit for turbidimeter TURB 2110; 0.02 NTU, 1.0 NTU and 10 NTU. Polymeric standards; No use of Formazin; most easy handling; Certified as alternative use secondary standards equivalent to freshly prepared Formazin Suspension Ref DIN EN ISO 7027. Approved as primary calibration standards (USEPA 180.1) |
361 |
600060 |
Xylem WTW |
Set for connection of turbidity meters series Turb 2000 and chlorine analyzer Chlorine 3000. Scope of delivery: 3 m (9.7 ft) PU-hose, 2 quick disconnect couplers for PU-hose with ¼” NPT female screw thread |
61 |
600062 |
Xylem WTW |
Adapter for A-Set-DW quick-lock coupling with ¼” NPT female screw thread to DN20 flange.: consisting of adapter and R½” double socket |
54 |
600064 |
Xylem WTW |
Adapter for A-Set-DW quick-lock coupling with ¼” NPT female screw thread to R½” female screw or male screw thread: constisting of adapter and R½” double socket |
46.8 |
600066 |
Xylem WTW |
Connection hose for Chlorine 3000 and turbidity meters Turb 2000 series. PU-hose, blue, 10 m (33 ft) |
40.6 |
801254 |
Xylem WTW |
Monitor for direct connection of analogue chlorine sensors, with 2 analog and relay outputs, Modbus,115V/230V and Pt1000 |
1380 |
801260 |
Xylem WTW |
Single Parameter Panel for measuring free or total chlorine in drinking water. Analog transmitter with 2 analog and 2 relay outputs, Modbus, 115V/230V. (order sensor separately) |
2620 |
801261 |
Xylem WTW |
Single Parameter Panel for measuring free or total chlorine in drinking water. Analog transmitter with 2 analog and 2 relay outputs, Modbus, FlowControl, 115V/230V. (Order sensor separately) |
2719 |
860151 |
Xylem WTW |
Online analyzer for photometric measurement of free and total chlorine, according to colorimetric DPD Method (ISO &US EPA); outputs (selectable): 4 to 20 mA or RS 485 Modbus; range: 0-5 mg/l; sample inlet device not included; |
5157 |
860160 |
Xylem WTW |
Dry reagent kit for the measurement of free chlorine, supply for 30 days. |
75 |
860165 |
Xylem WTW |
Dry reagent kit for the measurement of total chlorine, supply for 30 days. |
75 |
860170 |
Xylem WTW |
Dry reagent kit for the measurement of free chlorine, supply for 12 months |
883 |
860175 |
Xylem WTW |
Dry reagent kit for the measurement of total chlorine, supply for 12 months |
883 |
860180 |
Xylem WTW |
Replacement tubing for chlorine analyzer Chlorine 3000 |
147 |
860181 |
Xylem WTW |
Replacement tubing kit for the Chlorine 3017M |
144 |
860185 |
Xylem WTW |
Flow through cuvette for chlorine analyzer Chlorine 3000 |
66 |
860186 |
Xylem WTW |
Glass flow cell for the Chlorine 3017M |
46.8 |
860187 |
Xylem WTW |
Reagent caps Chlorine 3017M |
71 |
860188 |
Xylem WTW |
Sample inlet device Chlorine 3017M |
252 |
860189 |
Xylem WTW |
Replacement filter Chlorine 3017M |
39 |
860191 |
Xylem WTW |
Zero calibration Kit for chlorine analyzer Chlorine 3000 high-precision zero calibration, 115 VAC |
292 |
8F-00012 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
13704 |
8F-00014 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
13891 |
8F-00032 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
13704 |
8F-00034 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
13891 |
8F-00102 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
12098 |
8F-00104 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
12282 |
8F-00110 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
10158 |
8F-00112 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
14609 |
8F-00114 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
14795 |
8F-00130 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
10158 |
8F-00132 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
14609 |
8F-00134 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
14795 |
8F-01002 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
12133 |
8F-01004 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
12319 |
8F-01010 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
10195 |
8F-01012 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
14646 |
8F-01014 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
14831 |
8F-01030 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
10195 |
8F-01032 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
14646 |
8F-01034 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
14831 |
8F-01100 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
8587 |
8F-01102 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
13038 |
8F-01104 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
13224 |
8F-01110 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
11098 |
8F-01112 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
15550 |
8F-01114 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
15736 |
8F-01130 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
11098 |
8F-01132 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
15550 |
8F-01134 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
15736 |
8F-10002 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
12167 |
8F-10004 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
12351 |
8F-10010 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
10227 |
8F-10012 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
14678 |
8F-10014 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
14864 |
8F-10030 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
10227 |
8F-10032 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
14678 |
8F-10034 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
14864 |
8F-10100 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
8621 |
8F-10102 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
13071 |
8F-10104 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
13257 |
8F-10110 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
11132 |
8F-10112 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
15583 |
8F-10114 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
15770 |
8F-10130 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
11132 |
8F-10132 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
15583 |
8F-10134 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
15770 |
8F-11000 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
8658 |
8F-11002 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
13110 |
8F-11004 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
13293 |
8F-11010 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
11170 |
8F-11012 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
15622 |
8F-11014 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
15806 |
8F-11030 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
11170 |
8F-11032 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
15622 |
8F-11034 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
15806 |
8F-11100 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
9563 |
8F-11102 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
14014 |
8F-11104 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
14200 |
8F-11110 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
12075 |
8F-11112 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
16529 |
8F-11114 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
16711 |
8F-11130 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
12075 |
8F-11132 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
16529 |
8F-11134 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V, inc. flow |
16711 |
8T-00012 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
12687 |
8T-00014 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
12875 |
8T-00032 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
12687 |
8T-00034 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
12875 |
8T-00102 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
11081 |
8T-00104 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
11267 |
8T-00110 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
9141 |
8T-00112 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
13593 |
8T-00114 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
13777 |
8T-00130 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
9141 |
8T-00132 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
13593 |
8T-00134 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
13777 |
8T-01002 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
11118 |
8T-01004 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
11303 |
8T-01010 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
9176 |
8T-01012 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
13630 |
8T-01014 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
13815 |
8T-01030 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
9176 |
8T-01032 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
13630 |
8T-01034 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
13815 |
8T-01100 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
7570 |
8T-01102 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
12024 |
8T-01104 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
12208 |
8T-01110 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
10083 |
8T-01112 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
14535 |
8T-01114 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
14720 |
8T-01130 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
10083 |
8T-01132 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
14535 |
8T-01134 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
14720 |
8T-10002 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
11150 |
8T-10004 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
11337 |
8T-10010 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
9211 |
8T-10012 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
13666 |
8T-10014 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
13849 |
8T-10030 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
9211 |
8T-10032 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
13666 |
8T-10034 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
13849 |
8T-10100 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
7603 |
8T-10102 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
12057 |
8T-10104 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
12242 |
8T-10110 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
10116 |
8T-10112 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
14567 |
8T-10114 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
14753 |
8T-10130 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
10116 |
8T-10132 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
14567 |
8T-10134 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
14753 |
8T-11000 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
7643 |
8T-11002 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
12094 |
8T-11004 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
12279 |
8T-11010 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
10155 |
8T-11012 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
14606 |
8T-11014 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
14791 |
8T-11030 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
10155 |
8T-11032 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
14606 |
8T-11034 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
14791 |
8T-11100 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
8548 |
8T-11102 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
12998 |
8T-11104 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
13184 |
8T-11110 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
11058 |
8T-11112 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
15511 |
8T-11114 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
15696 |
8T-11130 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
11058 |
8T-11132 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
15511 |
8T-11134 |
Xylem WTW |
Drinking water panel (with Multiline 1000), 230 V |
15696 |
904000 |
Xylem WTW |
Pressure reduction valve. Input pressure max. 16 bar, outlet pressure 1.5-6 bar adjustable. DN10 for DW Panel with MULTILINE 1000 |
275 |
904005 |
Xylem WTW |
Dosing valve for flow regulation (0-90 l/min, DN10 PVC) |
347 |
904010 |
Xylem WTW |
Calibration console designed for drinking water panel MULTILINE 1000, PVC white |
37.5 |
108703 |
Xylem WTW |
TEP 10 Trace Technical buffer solution, 1 bottle with 1 l: pH 10.01 |
48 |
108800 |
Xylem WTW |
TPL 4 Technical buffer solution pH = 4.01, 1 bottle with 250 ml: pH 4.01 |
17 |
108802 |
Xylem WTW |
TPL 7 Technical buffer solution pH = 7.00, 1 bottle with 250 ml: pH 7.00 |
17 |
108805 |
Xylem WTW |
TPL 10 Trace Technical buffer solution pH = 10.01, 1 bottle with 250 ml: pH 10.01 |
17 |
109110 |
Xylem WTW |
PL 4 Standard (DIN/NBS) buffer solution, 1 bottle with 250 ml: pH 4.006/4.01 |
29.4 |
109120 |
Xylem WTW |
PL 7 Standard (DIN/NBS) buffer solution, 1 bottle with 250 ml: pH 6.865 /6.87 |
29.4 |
109130 |
Xylem WTW |
PL 9 Standard (DIN/NBS) buffer solution, 1 bottle with 250 ml: pH 9.180 /9.18 |
29.4 |
109740 |
Xylem WTW |
RH 28 ORP buffer solution pH 7, UH = 427 mV (CH), 1 bottle with 250 ml. |
45 |
300572 |
Xylem WTW |
E-SET Trace Calibration set for conductivity measurement, 6 bottles with 50 ml calibration and control standard each, KCl 0.01 mol/l, traceable to PTB/NIST. |
142 |
102274 |
Xylem WTW |
TFK 150 Temperature sensor for automatic temperature compensation with 3.3 ft (1 m) cable and waterproof plug |
361 |
102280 |
Xylem WTW |
TFK 325 Temperature sensor for automatic temperature compensation in aqueous solutions with 3.3 ft (1 m) cable and waterproof plug |
171 |
103630 |
Xylem WTW |
SenTix® 20 Epoxy pH combination electrode with gel electrolyte, S7 plug head, without cable. |
125 |
103631 |
Xylem WTW |
SenTix® 21 Epoxy pH combination electrode with gel electrolyte and waterproof DIN plug, 3.3 ft (1 m) cable. |
159 |
103632 |
Xylem WTW |
SenTix® 21-3 Epoxy pH combination electrode with gel electrolyte and waterproof DIN plug, 9.9 ft (3 m) cable. |
203 |
103633 |
Xylem WTW |
SenTix® 22 Epoxy pH combination electrode with gel electrolyte and BNC plug, 3.3 ft (1 m) cable. |
159 |
103635 |
Xylem WTW |
SenTix® 41 Epoxy pH combination electrode with gel electrolyte, integrated temperature sensor, waterproof DIN plug and banana plug, 3.3 ft (1 m) cable. |
241 |
103636 |
Xylem WTW |
SenTix® 41-3 Epoxy pH combination electrode with gel electrolyte, integrated temperature sensor, waterproof DIN plug and banana plug, 9.9 ft (3 m) cable. |
288 |
103637 |
Xylem WTW |
SenTix® 42 Epoxy pH combination electrode with gel electrolyte, integrated temperature sensor BNC plug and banana plug, 3.3 ft (1 m) cable. |
243 |
103639 |
Xylem WTW |
SenTix® 60 Glass pH combination electrode with liquid electrolyte, S7 plug head. Length 120 mm, without cable. |
178 |
103640 |
Xylem WTW |
SenTix® 61 Glass pH combination electrode with liquid electrolyte, waterproof DIN plug. Length 120 mm, 3.3 ft (1 m) cable. |
185 |
103641 |
Xylem WTW |
SenTix® 62 Glass pH combination electrode with liquid electrolyte, BNC plug. Length 120 mm, 3.3 ft (1 m) cable. |
185 |
103642 |
Xylem WTW |
SenTix® 81 Glass pH combination electrode with built-in temperature sensor, waterproof DIN plug and banana plug, length 120 mm, 3.3 ft (1 m) cable. |
283 |
103643 |
Xylem WTW |
SenTix® 82 Glass pH combination electrode with liquid electrolyte, built-in temperature sensor, BNC plug and banana plug, length 120 mm, 3.3 ft (1 m) cable. |
287 |
103644 |
Xylem WTW |
SenTix® H Precision pH combination electrode with ground diaphragm for high alkali ranges, high salt concentrations, length 165 mm, with S7 plug head, without connection cable. |
290 |
103645 |
Xylem WTW |
SenTix® Sp Spear-type pH combination electrode for penetration measurements in meat, fruit and cheese, S7 plug head, without cable. |
359 |
103646 |
Xylem WTW |
SenTix® Sur Surface pH combination electrode for measurements on smooth surfaces (e.g. paper, film material, etc.), S7 plug head, without cable. |
298 |
103647 |
Xylem WTW |
SenTix® Mic Micro pH combination electrode for measurements in small volumes or in small vessels, S7 plug head, shaft diameter 5 mm, without cable. |
333 |
103648 |
Xylem WTW |
SenTix® ORP ORP combination electrode (platinum - silver/silver chloride), plug head, length 120 mm. |
252 |
103650 |
Xylem WTW |
SenTix® HW Precision pH combination electrode with ground diaphragm for low-ionic media and S7 plug head, length 165 mm, without cable. |
296 |
103651 |
Xylem WTW |
SenTix® 51 Epoxy pH combination electrode with liquid electrolyte, waterproof DIN plug and banana plug, 3.3 ft (1 m) cable. |
268 |
103652 |
Xylem WTW |
SenTix® 52 Epoxy pH combination electrode with liquid electrolyte, BNC plug and banana plug, 3.3 ft (1 m) cable. |
268 |
103660 |
Xylem WTW |
SenTix® Mic-D Combination pH-micro electrode, diameter 3 mm, liquid electrolyte (3 mol/l KCl), platinum wire junction, 1 m cable with DIN plug. |
367 |
103661 |
Xylem WTW |
SenTix® Mic-B Combination pH micro electrode, diameter 3 mm, liquid electrolyte (3 mol/l KCl), platinum wire junction, 1 m cable with BNC plug. |
367 |
103664 |
Xylem WTW |
SenTix® Ag Combination Ag electrode with liquid electrolyte (2 mol/l KNO3 + 0,001 mol/l KCl), S7-plug head, for argentometry. |
280 |
103695 |
Xylem WTW |
SenTix® 91 Precision pH combination electrode, liquid electrolyte, built-in temperature sensor, DIN plug and banana plug. |
446 |
103710 |
Xylem WTW |
TA-SensoLyt SEA Combination pH electrode for installation in depth armature series TA 197-pH, polymer electrolyte, pin hole junction. |
341 |
103711 |
Xylem WTW |
TA-SensoLyt PtA ORP combination electrode (platinum) for installation in depth armature series TA 197-pH, polymer electrolyte, pin hole junction. |
424 |
103730 |
Xylem WTW |
SenTix® Sp-DIN Spear-type pH combination electrode for penetration measurements in meat, fruit and cheese, with fixed cable and waterproofed DIN plug. |
385 |
103731 |
Xylem WTW |
SenTix® HWD pH-electrode, NTC 30 kOhm, split ring junction, liquid electrolyte (3 mol/l KCl), 1 m fixed cable with DIN plug and 4 mm banana plug. |
416 |
103732 |
Xylem WTW |
SenTix® RJD pH electrode, NTC 30 kOhm, polymer electrolyte, split ring junction, glas shaft, 1 m fixed cabel with DIN plug and 4 mm banana plug. |
318 |
103733 |
Xylem WTW |
SenTix® Sp-T pH electrode for penetration measurements in meat, fruit and cheese, with built-in temperature sensor NTC 30 kOhm, 1 m fixed cable, waterproof DIN plug and 4 mm banana plug. |
390 |
103740 |
Xylem WTW |
SenTix® 940 IDS pH combination electrode with gel electrolyte, plastic shaft and integrated temperature sensor. QSC function. Electrode incl. 1.5 m fixed cable with waterproof digital connector. For MultiLine®, MonoLine, inoLab® IDS. |
279 |
103741 |
Xylem WTW |
SenTix® 940 -3 IDS pH combination electrode with gel electrolyte, plastic shaft and integrated temperature sensor. QSC function. Electrode incl. 3 m fixed cable with waterproof digital connector. For MultiLine® MonoLine, and inoLab® IDS. |
307 |
103743 |
Xylem WTW |
SenTix® 945 Low maintenance IDS pH electrode with gel electrolyte, glass shaft, three ceramic junctions, and integrated temperature sensor, 3 junctions. QSC function, memory for 10 calibrations. Electrode incl. 1.5 m fixed cable with waterproof digital connector for MultiLine, inoLab® IDS and MIQ/IDS. |
335 |
103744 |
Xylem WTW |
SenTix® Top 940 Low-maintenance IDS polymer pH electrode with robust PEEK shaft and hole diaphragm, with built-in temperature sensor, QSC-capable, memory for 10 calibrations, saved serial number, 1.5 m cable with digital connector for MultiLine® and inoLab® IDS. |
328 |
103748 |
Xylem WTW |
SensoLyt® 900-P Combined IDS pH electrode with polymer electrolyte and glass shaft, built-in temperature sensor, pressure resistant up to 10 bars. Electrode with waterproof plug head for connection to a MPP IDS or AS/IDS-x |
547 |
103749 |
Xylem WTW |
SensoLyt® ORP 900-P Combined IDS ORP electrode with polymer electrolyte and glass shaft, built-in temperature sensor, pressure resistant up to 10 bars. Electrode with waterproof plug head for connection to a MPP IDS or AS/IDS-x |
606 |
103750 |
Xylem WTW |
SenTix® 950 IDS pH combination electrode with liquid electrolyte, plastic shaft and integrated temperature sensor. QSC function. Electrode including 1.5 m fixed cable with waterproof digital connector, |
315 |
103751 |
Xylem WTW |
SenTix® Micro 900 IDS pH micro electrode, for measurement of small volumina and in small vessels, diameter 5 mm, with integrated temperature sensor, QSC function, memory for 10 calibrations, 1,5 m cable with digital connector for MultiLine®, MonoLine or inoLab® IDS. |
555 |
103752 |
Xylem WTW |
SenTix® Sp-T 900 IDS pH electrode for penetration measurement for measurement of meat, fruit or cheese with integrated temperature sensor, QSC function, memory for 10 calibrations serial number, 1.5 m cable with waterproof digital connector for MultiLine®, MonoLine or inoLab® IDS. |
404 |
103753 |
Xylem WTW |
SenTix® HW-T 900 IDS precision pH combination electrode with split ring junction for low-ionic media, length 165 mm with integrated temperature sensor, QSC function, memory for 10 calibrations, serial number, 1.5 m cable with waterproof digital connector for MultiLine®, MonoLine or inoLab® IDS. |
347 |
103760 |
Xylem WTW |
SenTix® 940-P IDS pH combination electrode with gel electrolyte, plastic shaft and integrated temperature sensor. QSC function. Electrode with plug head for AS IDS/1.5 cable or wireless module. |
279 |
103761 |
Xylem WTW |
SenTix® 950-P IDS pH combination electrode with liquid (3 mol/l KCl) electrolyte, plastic shaft and integrated temperature sensor. QSC function. Electrode with plug head for AS IDS/1.5 cable or wireless module. |
315 |
103762 |
Xylem WTW |
SenTix® 980-P IDS pH combination electrode with liquid electrolyte (3 mol/l KCl), glass shaft and integrated temperature sensor. QSC function. Electrode with plug head for AS IDS/1.5 cable or wireless module. |
316 |
103763 |
Xylem WTW |
SenTix® ORP-T 900-P Platinum IDS ORP electrode with liquid electrolyte (3 mol/l KCl) and glass shaft, temperature sensor. Electrode with plug head for AS IDS/1.5 cable or wireless module. |
290 |
103764 |
Xylem WTW |
SenTix® 945-P Low maintenance IDS pH electrode with gel electrolyte, glass shaft, three ceramic junctions, and integrated temperature sensor, 3 junctions. QSC function, memory for 10 calibrations. Electrode with plug head for AS IDS/1.5 cable or wireless module. |
335 |
103765 |
Xylem WTW |
SenTix® Micro 900-P IDS pH micro electrode, for measurement of small volumina and in small vessels, diameter 5 mm, with integrated temperature sensor, QSC function, memory for 10 calibrations, Electrode with plug head for AS IDS/1.5 cable or wireless module. |
555 |
103766 |
Xylem WTW |
SenTix® SP-T 900-P IDS pH electrode for penetration measurement for measurement of meat, fruit or cheese with integrated temperature sensor, QSC function, memory for 10 calibrations, serial number. Electrode with plug head for AS IDS/1.5 cable or wireless module. |
404 |
103767 |
Xylem WTW |
SenTix® HW-T 900-P Precision pH combination electrode with split ring junction for low-ionic media, length 165 mm with integrated temperature sensor, QSC function, memory for 10 calibrations, serial number. Electrode with plug head for AS IDS/1.5 cable or wireless module. |
347 |
103780 |
Xylem WTW |
SenTix® 980 IDS pH combination electrode with liquid electrolyte, glass shaft and integrated temperature sensor. QSC function. Electrode incl. 1.5 m fixed cable with waterproof digital connector, dropper vial with 3 mol/l KCl. |
316 |
103791 |
Xylem WTW |
SenTix® ORP-T 900 Platinum IDS ORP electrode with liquid electrolyte and glass shaft, temperature sensor. Electrode incl. 1.5 m fixed cable with waterproof digital connector, for MultiLine®, MonoLine and inoLab® IDS, dropper vial with 3 mol/l KCl. |
290 |
103792 |
Xylem WTW |
SenTix® Rx-T 900 ORP electrode with plastic shaft, fibre-junction, gel electrolyte, Ag/AgCl-reference system, temp.-sensor NTC 30 kOhm, sensor platinum pin 1 mm Ø, 1.5 m fixed cable with digital plug. |
251 |
103805 |
Xylem WTW |
SenTix® 43 Plastic pH electrode with gel electrolyte, integrated Pt 1000 temperature sensor, waterproof DIN plug and banana plug, 1 m cable |
257 |
103806 |
Xylem WTW |
SenTix® 44 Plastic pH electrode with gel electrolyte, integrated Pt 1000 temperature sensor, BNC plug and banana plug, 1 m cable |
253 |
103807 |
Xylem WTW |
SenTix® 46 Plastic pH electrode with gel electrolyte, integrated temperature sensor NTC 30 KOhm, BNC connector and cinch connector, 1 m cable, for external systems. |
257 |
103808 |
Xylem WTW |
SenTix® 47 Plastic pH electrode with gel electrolyte, integrated temperature sensor NTC 10 kOhm, BNC connector and 2 mm pin connector, 1 m cable (for Sartorius devices) |
253 |
103809 |
Xylem WTW |
SenTix® 57 Plastic pH electrode with liquid electrolyte, integrated temperature sensor NTC 10 kOhm, BNC connector and 2 mm pin connector, 1 m cable (for Sartorius devices) |
267 |
103810 |
Xylem WTW |
SenTix® 83 Glass pH electrode, liquid electrolyte, integrated Pt 1000 temperature sensor, waterproof DIN plug and banana plug, length 120 mm, 1 m cable |
298 |
103811 |
Xylem WTW |
SenTix® 84 Glass pH electrode, liquid electrolyte, integrated Pt 1000 temperature sensor, BNC plug and banana plug, length 120 mm, 1 m cable |
298 |
103812 |
Xylem WTW |
SenTix® 85 Glass pH electrode, liquid electrolyte, integrated Pt 1000 temperature sensor, BNC plug and 2 x banana plugs, length 120 mm, 1 m cable |
295 |
103813 |
Xylem WTW |
SenTix® 86 Glass pH electrode, liquid electrolyte, BNC connector and Cinch connector, length 120 mm, 1 m cable, for external systems |
287 |
103814 |
Xylem WTW |
SenTix® 87 Glass pH electrode, liquid electrolyte, integrated temperature sensor NTC 10 kOhm, BNC connector and 2 mm pin connector, length 120 mm, 1 m cable (for Sartorius devices) |
287 |
103815 |
Xylem WTW |
SenTix® Rx ORP electrode with plastic shaft and gel electrolyte (platinum silver/silver chloride), with plug head, length 120 mm |
207 |
103816 |
Xylem WTW |
SenTix® Top 41 Robust plastic pH electrode, shaft material PEEK, polymer electrolyte, pinhole junction, integrated temperature sensor, waterproof DIN plug and banana plug, 1 m cable |
283 |
103817 |
Xylem WTW |
SenTix® Top 46 Robust plastic pH electrode, shaft material PEEK, polymer electrolyte, perforated diaphragm, integrated temperature sensor, BNC connector and cinch connector, 1 m cable, for external systems. |
283 |
106395 |
Xylem WTW |
NH 500/2 Ammonia gas-sensitive combination electrode with plug head, 0.02 to 900 mg/l, requires ionic strength adapter MZ/NH3/CN standard solution ES/NH4. 3 exchange heads and 50 ml electrolyte solution. |
1119 |
106575 |
Xylem WTW |
ELY/BR/503 Universal bridge electrolyte (except for nitrate and potassium measurements) for reference electrode 503, 1 bottle, contents 250 ml. |
132 |
106576 |
Xylem WTW |
ELY/BR/503/N Bridge electrolyte for nitrate measurements, for reference electrode 503, 1 bottle, contents 250 ml. |
132 |
106577 |
Xylem WTW |
ELY/BR/503/K Bridge electrolyte for potassium measurements, for reference electrode 503, 1 bottle, contents 250 ml. |
132 |
106580 |
Xylem WTW |
ISA/K ISA solution for potassium measurements, 2 bottles with 250 ml. |
132 |
106649 |
Xylem WTW |
Na 800/S7 Sodium ion selective glass alectrode with S7 plug head, reference electrolyte 3 mol/l KCl. Measuring range 0.01 mg/l … 23,000 mg/l. (0,000001 mol/l to 1 mol/l). Requires standard solution ES/Na, ion strenght adjustment solution ISA/Na, cable AS/DIN or AS/BNC |
599 |
106651 |
Xylem WTW |
Ag/S 800 DIN Silver ion/sulfide combined ion selective electrode, 1 m (3.3 ft) cable, DIN plug, 0.003 to 32,000 mg/l, requires ELY/BR/503 reference electrolyte, ionic strength adapter ISA/FK (Ag-ions) or according instruction manual for sulfide measurement. Standard solutions have to be prepared freshly. |
1308 |
106653 |
Xylem WTW |
Br 800 DIN Combined Bromide selective electrode, 3.3 ft (1 m) cable, DIN plug, 0.4 to 79,000 mg/l, requires ELY/BR/503 reference electrolyte, ionic strength adapter ISA/FK, standard solution ES/Br. Delivery contains electrolyte! |
1286 |
106655 |
Xylem WTW |
Ca 800 DIN Combined Calcium ion selective electrode, with 3.3 ft (1 m) cable, DIN plug, 0.02 to 40,000 mg/l, requires ELY/BR/503 reference electrolyte, ionic strength adapter ISA/Ca standard solution ES/Ca. Delivery contains electrolyte and exchange heads! |
1298 |
106656 |
Xylem WTW |
CA 800/AT Exchange head for combined Calcium-ion selective electrode Ca 800. |
513 |
106661 |
Xylem WTW |
Cl 800 DIN Combined Chloride selective electrode, with 3.3 ft (1 m) cable, DIN plug, 2 to 35,000 mg/l, requires ELY/BR/503 reference electrolyte, ionic strength adapter ISA/FK, standard solution ES/Cl. Delivery contains electrolyte! |
1250 |
106663 |
Xylem WTW |
CN 800 DIN Combined Cyanide selective electrode, with 3.3 ft (1 m) cable, DIN plug, 0.2 to 260 mg/l requires ELY/BR/503 reference electrolyte, ionic strength adapter MZ/NH3/CN. Standard solutions have to be prepared freshly. Delivery contains electrolyte! |
1250 |
106665 |
Xylem WTW |
Cu 800 DIN Combined Copper ion selective electrode, with 3.3 ft (1 m) cable, DIN plug, 0.0006 to 6400 mg/l, requires ELY/BR/503 reference electrolyte, ionic strength adapter ISA/FK, standard solution ES/Cu. Delivery contains electrolyte! |
1558 |
106666 |
Xylem WTW |
F 800 BNC Combined Fluoride selective electrode, with 3.3 ft (1 m) cable, BNC plug, 0.02 mg/l to saturation, requires ELY/BR/503 reference electrolyte, ionic strength adapter TISAB, standard solution ES/F. Delivery contains electrolyte! |
1250 |
106667 |
Xylem WTW |
F 800 DIN Combined Fluoride selective electrode, with 3.3 ft (1 m) cable, DIN plug, 0.02 mg/l to saturation, requires ELY/BR/503 reference electrolyte, ionic strength adapter TISAB, standard solution ES/F. Delivery contains electrolyte! |
1250 |
106671 |
Xylem WTW |
K 800 DIN Combined Potassium ion selective electrode, with 3.3 ft (1 m) cable, DIN plug, 0.04 to 39,000 mg/l, requires ELY/BR/503/K reference electrolyte, ionic strength adapter ISA/K, standard solution ES/K. Delivery contains electrolyte and exchange heads! |
1298 |
106672 |
Xylem WTW |
K 800/AT Exchange head for Potassium-ion selective electrode K 800. |
513 |
106675 |
Xylem WTW |
NO 800 DIN Combined Nitrate selective electrode, with 3.3 ft (1 m) cable, DIN plug, 0.4 to 62,000 mg/l, requires ELY/BR/503/N reference electrolyte, ionic strength adapter TISAB/NO3, standard solution ES/NO3. Delivery contains electrolyte and exchange heads! |
1298 |
106676 |
Xylem WTW |
NO 800/AT Exchange head for Nitrate selective electrode NO 800. |
513 |
108060 |
Xylem WTW |
D 530 Flow-through vessel for pH combination electrodes (shaft diameter 12 mm/0.47 in), temperature sensor TFK 150 and TFK 530 and for conductivity cells LTA 01 and LR 325/01. |
442 |
108062 |
Xylem WTW |
MG/pH Measuring vessel for determinating the pH of drinking water, suitable for pH combimation electrodes SenTix® 81, also for use as storage vessel for pH electrodes. |
71 |
108064 |
Xylem WTW |
MB 50 Beaker, 50 ml |
12.4 |
108065 |
Xylem WTW |
pH-Cap Replacement moisturing cap for SenTix® pH sensors (12 mm shaft diameter). |
6.5 |
108110 |
Xylem WTW |
AS/DIN Connection cable with DIN plug for pH/ORP electrodes with plug head, 3.3 ft (1 m) cable. |
51 |
108112 |
Xylem WTW |
AS/DIN - 3 Connection cable with DIN plug for pH/ORP electrodes with plug head, 9.9 ft (3 m) cable. |
70 |
108114 |
Xylem WTW |
AS/BNC Connection cable with BNC plug for pH/ORP electrodes with plug head, 3.3 ft (1 m) cable. |
51 |
108130 |
Xylem WTW |
ADA S7/IDS Adapter cable 1.5 m with digital connector, for connecting a SenTix® combination electrode with S7 plug head to a MultiLine® or inoLab® IDS. |
248 |
108131 |
Xylem WTW |
ADA 94pH/IDS DIN pH/mV module for inoLab® Multi 9x20/30 IDS for pH/ORP/ISE electrodes with DIN- and 4 mm banana plug. Including mounting accessories. |
296 |
108132 |
Xylem WTW |
ADA 94pH/IDS BNC pH/mV module for inoLab® Multi 9x20/30 IDS for pH/ORP/ISE electrodes with BNC- and 4 mm banana plug. Including mounting accessories. |
296 |
108141 |
Xylem WTW |
IDS WLM-S Wireless module for IDS plug head sensors for radio transmission of measurement values. Includes rechargeable LiPo-battery. Splash water protected acccording IP 66. |
175 |
108142 |
Xylem WTW |
IDS WLM-M Wireless module for connecting to MultiLine® 3310/3510/36x0 IDS, inoLab® Multi IDS and MonoLine. Connects up to three sensors at the same time (depends on meter capabilities). Also for operation of OxiTop®-IDS. |
142 |
108143 |
Xylem WTW |
WLM Charger Charger without external power supply for charging IDS WLM-S modules, with USB plug, cascadable, with USB cable. For charging via PC or extrenal USB power supply. |
118 |
108144 |
Xylem WTW |
IDS WLM Kit Kit consisting of one of each IDS WLM-S, IDS WLM-M and WLM Charger including USB power supply for wireless operation of IDS plug head sensors. |
385 |
108509 |
Xylem WTW |
ADA-DIN-BNC Adapter for connecting pH electrodes with BNC plug to a meter with DIN socket. |
73 |
108698 |
Xylem WTW |
TEP 2 Technical buffer solution, 1 bottle with 1 l: pH 2.00 |
79 |
108700 |
Xylem WTW |
TEP 4 Technical buffer solution, 1 bottle with 1 l: pH 4.01 |
48 |
108701 |
Xylem WTW |
TEP 4/10 Technical buffer solution pH = 4.01; Box with 10 bottles with 1 liter each. |
398 |
108702 |
Xylem WTW |
TEP 7 Technical buffer solution, 1 bottle with 1 l: pH 7.00 |
48 |
108703 |
Xylem WTW |
TEP 10 Trace Technical buffer solution, 1 bottle with 1 l: pH 10.01 |
48 |
108706 |
Xylem WTW |
STP 4 Technical buffer solution, 1 bottle with 50 ml: pH 4.01 |
14.6 |
108708 |
Xylem WTW |
STP 7 Technical buffer solution, 1 bottle with 50 ml: pH 7.00 |
14.6 |
108722 |
Xylem WTW |
STP 10 TRACE Technical buffer solution, 1 bottle with 50 ml: pH 10.01 |
14.6 |
108725 |
Xylem WTW |
TEP 7/10 Technical buffer solution pH = 7.00; Box with 10 bottles with 1 liter each. |
398 |
108727 |
Xylem WTW |
TEP 10 Trace/10 Technical buffer solution pH = 10.01; Box with 10 bottles with 1 liter each. |
398 |
108728 |
Xylem WTW |
TEP 4/25 Technical buffer solution pH = 4.01; Box with 25 bottles with 1 liter each. |
917 |
108729 |
Xylem WTW |
TEP 7/25 Technical buffer solution pH = 7.00; Box with 25 bottles with 1 liter each. |
917 |
108731 |
Xylem WTW |
TEP 10 Trace/25 Technical buffer solution pH = 10.01; Box with 25 bottles with 1 liter each. |
917 |
108800 |
Xylem WTW |
TPL 4 Technical buffer solution pH = 4.01, 1 bottle with 250 ml: pH 4.01 |
17 |
108801 |
Xylem WTW |
TPL 4/10 Technical buffer solution pH = 4.01; Box with 10 bottles with 250 ml each. |
150 |
108802 |
Xylem WTW |
TPL 7 Technical buffer solution pH = 7.00, 1 bottle with 250 ml: pH 7.00 |
17 |
108803 |
Xylem WTW |
TPL 7/10 Technical buffer solution pH = 7.00; Box with 10 bottles with 250 ml each. |
150 |
108805 |
Xylem WTW |
TPL 10 Trace Technical buffer solution pH = 10.01, 1 bottle with 250 ml: pH 10.01 |
17 |
108809 |
Xylem WTW |
TPL 10 Trace/10 Technical buffer solution pH = 10.01; Box with 10 bottles with 250 ml each. |
150 |
108811 |
Xylem WTW |
TPL 4/25 Technical buffer solution pH = 4.01; Box with 25 bottles with 250 ml each. |
371 |
108812 |
Xylem WTW |
TPL 7/25 Technical buffer solution pH = 7.00; Box with 25 bottles with 250 ml each. |
371 |
108814 |
Xylem WTW |
TPL 10 Trace/25 Technical buffer solution pH = 10.01; Box with 25 bottles with 250 ml each. |
371 |
108824 |
Xylem WTW |
SORT/TPL/TRACE Calibration and maintenance set with technical buffer solution, 3 bottles with 250 ml each: pH 4.01/ 7.00/ 10.01 Trace, 1 bottle with 250 ml pepsin cleaning solution, 1 bottle with 250 ml 3 mol/l KCl solution. |
92 |
108825 |
Xylem WTW |
SORT/TPL/G/TRACE Calibration and maintenance set with technical buffer solution for gel electrodes, 3 bottles with 250 ml each: pH 4.01/ 7.00/ 10.01 Trace, 2 bottles with 250 ml 3 mol/l KCl solution. |
81 |
108826 |
Xylem WTW |
SORT/TEP/TRACE Calibration and maintenance set with technical buffer solution 3 bottles with 1 l each: pH 4.01/ 7.00/ 10.01, 1 bottle with 250 ml pepsin cleaning solution, 1 bottle with 250 ml KCl solution 3 mol/l. |
182 |
108827 |
Xylem WTW |
SORT/TEP/G/TRACE Calibration and maintenance set with technical buffer solution for gel electrodes, 3 bottles with 1 l each: pH 4.01/ 7.00/ 10.01 Trace, 2 bottles with 250 ml 3 mol/l KCl solution. |
171 |
109000 |
Xylem WTW |
PL 2 Standard (DIN/NIST) buffer solution for special applications, 1 bottle with 250 ml: pH 1.679/1.68. |
31.8 |
109020 |
Xylem WTW |
STAPL-4/7/9 Working reference buffer solution pH 4.01, pH 6.87 pH 9.18. Traceable to NIST/PTB. Steam-sterilized package. Package with 10 x 6 glass ampoules, 20 ml each. |
215 |
109110 |
Xylem WTW |
PL 4 Standard (DIN/NBS) buffer solution, 1 bottle with 250 ml: pH 4.006/4.01 |
29.4 |
109120 |
Xylem WTW |
PL 7 Standard (DIN/NBS) buffer solution, 1 bottle with 250 ml: pH 6.865 /6.87 |
29.4 |
109130 |
Xylem WTW |
PL 9 Standard (DIN/NBS) buffer solution, 1 bottle with 250 ml: pH 9.180 /9.18 |
29.4 |
109316 |
Xylem WTW |
EH/70 SW Replacement electrode holder with titanium bail, fitting for MPP 930, included with set. |
220 |
109400 |
Xylem WTW |
PL 12 Standard (DIN/NIST) buffer solution for special applications, 1 bottle with 250 ml: pH 12,47 |
32.7 |
109415 |
Xylem WTW |
SORT/K Calibration and maintenance set with standard (DIN/NIST) buffer solution, 3 bottles, 250 ml each: pH 4.006 - 6.865 - 9.180, 1 bottle with 250 ml pepsin cleaning solution, 1 bottle with 250 ml KCl solution 3 mol/l. |
113 |
109648 |
Xylem WTW |
PEP/pH (3x250ml) Pepsin cleaning solution only for electrodes with liquid electrolytes, 3 bottles, 250 ml each. Use only for pH electrodes with liquid electrolyte |
80 |
109705 |
Xylem WTW |
KCl-250 Reference electrolyte, 1 bottle with 250 ml KCl solution 3 mol/l. |
26.5 |
109706 |
Xylem WTW |
KCl-50 KCl solution, 3 mol/l, small bottle with 50 ml. |
10.4 |
109735 |
Xylem WTW |
ELY/ORP/Ag Electrolyte (2 mol/l KNO3 + 0.001 mol/l KCl) for combined ORP electrode with Ag-electrode. |
43.5 |
109740 |
Xylem WTW |
RH 28 ORP buffer solution pH 7, UH = 427 mV (CH), 1 bottle with 250 ml. |
45 |
109809 |
Xylem WTW |
STH 650 Benchtop stand for pH electrodes, ion-sensitive electrodes, reference electrodes, temp sensors, oxygen sensors and TetraCon® 325 cond cells. |
241 |
109813 |
Xylem WTW |
STH 9400 Stand including electrode holder for right or left mounting, for inoLab 94x0 |
256 |
109818 |
Xylem WTW |
TFK 325/HC Temperature sensor for automatic temperature compensation in aqueous solutions, with 3.3 ft (1 m) cable and waterproof plug, built-in holding clip for pH electrodes. |
187 |
109821 |
Xylem WTW |
HC 325 Holding clip for SenTix® pH electrodes for temperature sensor TFK 325 |
95 |
109823 |
Xylem WTW |
TFK 325/HC-3 Temperature sensor for automatic temperature compensation with 9.8 ft (3 m) cable and waterproof plug, built-in holding clip for pH electrodes. |
200 |
109830 |
Xylem WTW |
QSC Kit Initial calibration kit for IDS pH electrodes. Box with 3 ampoules, pH 4.01, pH 6.86, pH 9.18. |
33.1 |
120120 |
Xylem WTW |
ES/ Br Standard solution: 10 g/l bromide, 1 bottle with 1 l |
142 |
120140 |
Xylem WTW |
ES/ CL Standard solution: 10 g/l chloride, 1 bottle with 1 l |
142 |
120160 |
Xylem WTW |
ES/ F Standard solution: 10 g/l fluoride, 1 bottle with 1 l |
142 |
120190 |
Xylem WTW |
ES/ Cu Standard solution: 10 g/l copper, 1 bottle with 1 l |
142 |
120200 |
Xylem WTW |
ES/ Ca Standard solution: 10 g/l calcium, 1 bottle with 1 l |
142 |
120210 |
Xylem WTW |
ES/ K Standard solution: 10 g/l potassium, 1 bottle with 1 l |
142 |
120220 |
Xylem WTW |
ES/ NO3 Standard solution: 10 g/l nitrate, 1 bottle with 1 l |
142 |
120222 |
Xylem WTW |
ES/Na Standard solution: 10 g/l sodium, 1 bottle with 1 l |
142 |
120240 |
Xylem WTW |
ES/NH4 Standard solution: 10 g/l ammonium, 1 bottle with 1 l |
142 |
140100 |
Xylem WTW |
TISAB TISAB total ionic strength buffer solution for fluoride electrode, 4 bottles with 1 l each. |
290 |
140110 |
Xylem WTW |
ISA/FK ISA sample conditioning solution for for solid state electrodes, NaNO3, 5 mol/l, 2 bottles with 250 ml each. |
132 |
140120 |
Xylem WTW |
ISA/Ca ISA sample conditioning solution for calcium electrode, KCl, 4 mol/l, 1 bottle with 250 ml. |
132 |
140140 |
Xylem WTW |
ISA/Ag/Fl ISA for determination of silver in fixer solution for Silver/Sulfide electrode Ag 500, 4 bottles with 1 l each. |
290 |
150120 |
Xylem WTW |
TISAB/NO3 TISAB total ionic strength buffer solution for nitrate electrodes, 4 bottles with 1 l each. |
290 |
150125 |
Xylem WTW |
ISA/Na Total ionic strength buffer solution pH 11, 1 bottle with 1 l. |
107 |
150130 |
Xylem WTW |
MZ/NH3/CN Alkaline reagent, NaOH, 10 mol/l, 1 bottle with 250 ml. |
128 |
180100 |
Xylem WTW |
ZBK/NH3/2 Accessory box for ammonia electrode NH 500/2, 3 exchange heads and 50 ml electrolyte solution. |
472 |
180130 |
Xylem WTW |
S/FK Polishing strips for solid state electrodes, 24 pcs. |
67 |
1AA110 |
Xylem WTW |
inoLab® pH 7110 Easy-to-operate basic pH/mV benchtop meter with DIN socket for routine measurement. For AC and battery operation. Single meter with universal power supply, stand and operation manual. |
778 |
1AA112 |
Xylem WTW |
inoLab® pH 7110 SET 2 Easy-to-operate basic pH/mV benchtop meter with DIN socket for routine measurement. For AC and battery operation. Meter with universal power supply, stand and operation manual. Combined pH electrode SenTix® 41, buffer 4, 7 and 10.01, 3 mol/l KCl |
1006 |
1AA114 |
Xylem WTW |
inoLab® pH 7110 SET 4 Easy-to-operate basic pH/mV benchtop meter with DIN socket for routine measurement. For AC and battery operation. Meter with universal power supply, stand and operation manual. Combined pH electrode SenTix® 81, buffer 4, 7 and 10.01, 3 mol/l KCl |
1035 |
1AA120 |
Xylem WTW |
inoLab® pH 7110 BNC Easy-to-operate basic pH/mV benchtop meter with BNC socket for routine measurement. For AC and battery operation. Single meter with universal power supply, stand and operation manual. |
779 |
1AA310 |
Xylem WTW |
inoLab® pH 7310 Convenient, menu controlled pH/mV meter for measurements/documentation according GLP/AQA. For AC and battery operation. Single meter with universal power supply, stand and operation manual. CD-ROM including software and USB cable. |
1103 |
1AA310P |
Xylem WTW |
inoLab® pH 7310P Convenient, menu controlled pH/mV meter for measurements/documentation according GLP/AQA, with integrated thermal printer. Single meter with universal power supply, stand and operation manual. CD-ROM including software and USB cable. |
1602 |
1AA312 |
Xylem WTW |
inoLab® pH 7310 SET 2 Convenient, menu controlled pH/mV meter for measurements/documentation according GLP/AQA. Set including combined pH electrode. Meter with universal power supply, stand and operation manual. Combined pH electrode SenTix® 41, buffer 4, 7 and 10.01, 3 mol/l KCl, software and USB cable. |
1332 |
1AA314 |
Xylem WTW |
inoLab® pH 7310 SET 4 Convenient, menu controlled pH/mV meter for measurements/documentation according GLP/AQA. Set including combined pH electrode. Meter with universal power supply, stand and operation manual. Combined pH electrode SenTix® 81, buffer 4, 7 and 10.01, 3 mol/l KCl, software and USB cable. |
1361 |
1AA320 |
Xylem WTW |
inoLab® pH 7310 BNC Convenient, menu controlled pH/mV meter, BNC socket, for measurements/documentation according GLP/AQA. For AC and battery operation. Meter with universal power supply, stand and operation manual, software and USB cable. |
1103 |
1AA320P |
Xylem WTW |
inoLab® pH 7310P BNC Convenient, menu controlled pH/mV meter, BNC socket, for measurements/documentation according GLP/AQA, with integrated thermal printer. Meter with universal power supply, stand and operation manual, software and USB cable. |
1602 |
1BA300 |
Xylem WTW |
inoLab® Oxi 7310 Professional dissolved oxygen meter, menu controlled, for measurements / documentation according GLP/AQA. For AC and battery operation. Meter with universal power supply, stand and operation manual, software and USB cable. |
1676 |
1BA300P |
Xylem WTW |
inoLab® Oxi 7310P Professional dissolved oxygen meter, menu controlled, for measurements / documentation according GLP/AQA, with integrated thermal printer. Meter with universal power supply, stand and operation manual, software and USB cable. |
2245 |
1BA301 |
Xylem WTW |
inoLab® Oxi 7310 SET 1 Professional dissolved oxygen meter, menu controlled, for measurements / documentation according GLP/AQA. Set including galvanic D.O. sensor. Meter with universal power supply, stand and operation manual, galvanical D.O. sensor CellOx® 325, abrasive foil, electrolyte, replacement caps, CD-ROM incl. Software, USB cable. Note: Please order cleaning solution RL-G 205204 separately! |
2319 |
1BA304 |
Xylem WTW |
inoLab® Oxi 7310 SET 4 Professional dissolved oxygen meter, menu controlled, for measurements / documentation according GLP/AQA. Set including galvanic D.O. sensor. Meter with universal power supply, stand and operation manual, self stirring galvanic D.O. sensor StirrOx® G, abrasive foil, electrolyte, replacement caps, CD-ROM incl. Software, USB cable. Note: Please order cleaning solution RL-G 205204 separately! |
2617 |
1CA100 |
Xylem WTW |
inoLab® Cond 7110 Easy-to-operate basic conductivity benchtop meter for routine measurement. For AC and battery operation. Meter with universal power supply, stand and operation manual. |
1048 |
1CA101 |
Xylem WTW |
inoLab® Cond 7110 SET 1 Easy-to-operate basic conductivity benchtop meter for routine measurement. For AC and battery operation. Set including conductivity cell. Meter with universal power supply, stand and operation manual.Incl. 4-electrode graphite conductivity cell TetraCon® 325, 0.01 mol/l KCl conductivity standard. |
1428 |
1CA300 |
Xylem WTW |
inoLab® Cond 7310 Precise and convenient conductivity meter, menu controlled, for measurements/documentation according GLP/AQA. For AC and battery operation. Meter with universal power supply, stand and operation manual. software and USB cable. |
1315 |
1CA300P |
Xylem WTW |
inoLab® Cond 7310P Precise and convenient conductivity meter, menu controlled, for measurements/documentation according GLP/AQA, with integrated thermal printer. Meter with universal power supply, stand and operation manual, software and USB cable. |
1824 |
1CA301 |
Xylem WTW |
inoLab® Cond 7310 SET 1 Precise and convenient conductivity meter, menu controlled, for measurements/documentation according GLP/AQA. For AC and battery operation. Set including conductivity cell. Meter with universal power supply, stand and operation manual. Including 4-electrode graphite conductivity cell TetraCon® 325, 0.01 mol/l KCl conductivity standard, software and USB cable. |
1779 |
1FD350 |
Xylem WTW |
inoLab® Multi 9310 IDS Digital multiparameter benchtop meter for IDS sensors, for measurements / documentation according GLP/AQA. With an universal input for IDS pH/ORP, conductivity and D.O. sensors. Meter with universal power supply, stand and operation manual, software and USB cable. |
1289 |
1FD350P |
Xylem WTW |
inoLab® Multi 9310P Digital multiparameter benchtop for IDS sensors with integrated printer for measurements / documentation according GLP/AQA, with integrated thermal printer. With an universal input for IDS pH/ORP, conductivity and D.O. sensors. Meter with universal power supply, stand, operation manual, software and USB cable. |
1802 |
1FD351 |
Xylem WTW |
inoLab® Multi 9310 SET 1 Digital multiparameter benchtop meter with single universal input for IDS sensors, for measurements / documentation according GLP/AQA. Set including IDS sensor. Meter with universal power supply, stand and operation manual, digital IDS pH electrode SenTix® 940, buffer 4, 7 and 10.01, 3 mol/l KCl, software and USB cable. |
1568 |
1FD352 |
Xylem WTW |
inoLab® Multi 9310 SET 2 Digital multiparameter benchtop meter with universal single input for IDS sensors, for measurements / documentation according GLP/AQA. Set including IDS sensor. Meter with universal power supply, stand and operation manual, digital IDS pH electrode SenTix® 980, buffer 4, 7 and 10.01, 3 mol/l KCl, software and USB cable. |
1600 |
1FD353 |
Xylem WTW |
inoLab® Multi 9310 SET 3 Digital multiparameter benchtop meter with universal single input for IDS sensors, for measurements / documentation according GLP/AQA. Set including IDS sensor. Meter with universal power supply, stand and operation manual, digital IDS conductivity cell TetraCon® 925, 0.01 mol/l KCl, conductivity standard, software and USB cable. |
1854 |
1FD354 |
Xylem WTW |
inoLab® Multi 9310 SET 4 Digital multiparameter benchtop meter with universal single input for IDS sensors, for measurements / documentation according GLP/AQA. Set including IDS sensor. Meter with universal power supply, stand and operation manual, optical IDS D.O. sensor FDO® 925, software and USB cable. |
2276 |
1FD35C |
Xylem WTW |
inoLab® Multi 9310 SET C Digital multiparameter benchtop meter with universal single input for IDS sensors, for measurements / documentation according GLP/AQA. Set including IDS sensors. Meter with universal power supply, stand and operation manual, digital IDS pH electrode SenTix® 940, buffer 4, 7 and 10.01, 3 mol/l KCl, digital IDS conductivity cell TetraCon® 925, 0.01 mol/l KCl, conductivity standard, software and USB cable. |
2136 |
1FD560 |
Xylem WTW |
inoLab® Multi 9620 IDS Professional digital multiparameter benchtop meter, wireless ready, for IDS sensors, for measurements/documentation according GLP/AQA. With two universal inputs for pH/mV/ISE, dissolved oxygen, turbidity and conductivity. Meter including universal power supply, stand and operation manual, software and USB cable. |
2259 |
1FD56C |
Xylem WTW |
inoLab® Multi 9620 SET C Professional digital multiparameter benchtop meter, wireless ready, for IDS sensors, for measurements/documentation according GLP/AQA. With two universal inputs for pH/mV/ISE, dissolved oxygen, turbidity and conductivity. Set including universal power supply, stand and operation manual, digital IDS pH electrode SenTix® 980, buffer 4, 7 and 10.01, QSC Kit (EUC mandatory) 3 mol/l KCl, IDS 4-electrode conductivity cell TetraCon® 925, 0.01 mol/l conductivity standard. Software and USB cable. |
3079 |
1FD570 |
Xylem WTW |
inoLab® Multi 9630 IDS Professional digital multiparameter benchtop meter, wireless ready, for IDS sensors, for measurements/documentation according GLP/AQA. With three universal inputs for pH/mV/ISE, dissolved oxygen, turbidity and conductivity. Meter including universal power supply, stand and operation manual, software and USB cable. |
3080 |
1FD57K |
Xylem WTW |
inoLab® Multi 9630 SET K Professional digital multiparameter benchtop meter, wireless ready, for IDS sensors, for measurements/documentation according GLP/AQA. With three universal inputs for pH/mV/ISE, dissolved oxygen and conductivity. Set including universal power supply, stand and operation manual, digital IDS pH electrode SenTix® 980, buffer 4, 7 and 10.01, QSC-Kit (requites EUC), 3 mol/l KCl, optical IDS oxygen sensor FDO® 925.IDS 4-electrode conductivity cell TetraCon® 925, software and USB cable. |
4906 |
1FD680 |
Xylem WTW |
IDS Gate Gateway with REST API interface for precision data sets. Suitable for pH, ORP, conductivity and dissolved oxygen from IDS wireless sensors. For calibration of sensors, an IDS portable or benchtop meter is required. Including power supply and antenna. |
1173 |
1GA330 |
Xylem WTW |
inoLab® pH/ION 7320 Precise, menu controlled pH/mV/ISE benchtop meter, with two DIN inputs, for measurements/documentation according GLP/AQA. Meter with universal power supply, stand and operation manual, software and USB cable. |
2111 |
1GA330P |
Xylem WTW |
inoLab® pH/ION 7320P Precise, menu controlled pH/mV/ISE benchtop meter, with two DIN inputs, for measurements/documentation according GLP/AQA with built-in thermal printer. Meter with universal power supply, stand and operation manual, software and USB cable. |
2611 |
1GA340 |
Xylem WTW |
inoLab® pH/ION 7320 BNC Precise, menu controlled pH/mV/ISE benchtop meter, with two BNC inputs, for measurements/documentation according GLP/AQA. Meter with universal power supply, stand and operation manual, software and USB cable. |
2111 |
1GA340P |
Xylem WTW |
inoLab® pH/ION 7320P BNC Precise, menu controlled pH/mV/ISE benchtop meter, with two BNC inputs, for measurements/documentation according GLP/AQA with built-in thermal printer. Meter with universal power supply, stand and operation manual, software and USB cable. |
2611 |
1P21- |
Xylem WTW |
CR 2200 Thermoreactor for COD and thermal digestions for up to 12 reaction cuvettes, with 4 reactors temperatures, 8 fixed programs, 115/230 V, regional plug. |
1110 |
1P22- |
Xylem WTW |
CR 3200 Thermoreactor for COD and thermal digestions, up to 24 cells with one program setting, 8 fixed / 8 user defined programs with free temperature setting up to 170°C, 230/115V, regional plug. Optional accessories: external temperature sensor TFK CR for AQA - temperature monitoring (250 100). |
1592 |
1P23- |
Xylem WTW |
CR 4200 Thermoreactor for COD and thermal digestions, 2 x 12 cells optional with 2 different program settings, 8 fixed / 8 user defined programs with free temperature setting up to 170°C, optional accessories: external temperature sensor TFK CR for AQA - temperature monitoring (250 100). |
1961 |
201300 |
Xylem WTW |
FDO® 925 Optical IDS DO sensor for field and laboratory applications with fast responding bevelled membrane, with 1.5 m (4.9 ft) fixed cable with waterproof digital connector. |
1055 |
201301 |
Xylem WTW |
FDO® 925 -3 Optical IDS DO sensor for field and laboratory applications with fast responding bevelled membrane, with 3 m (9.7 ft) fixed cable with waterproof digital connector. |
1078 |
201306 |
Xylem WTW |
FDO® 925-P Optical IDS DO sensor for field and lab applications with fast responding beveled membrane, pressure resistant up to 10 bars. Electrode with waterproof plug head for connection to a MPP IDS, wireless module or AS/IDS-x |
1075 |
201310 |
Xylem WTW |
SC-FDO® 925 Exchange cap for FDO® 925 type sensors |
192 |
201311 |
Xylem WTW |
FDO® Check Replacement check and calibration vessel for FDO® 925 type sensors |
206 |
201312 |
Xylem WTW |
ADA FDO®/RZ Replacement stainless steel adapter for mounting a RZ 300 magnetic stirrer paddle for BOD measurement on a FDO® 925, also suitable as membrane protection. |
44.8 |
201425 |
Xylem WTW |
StirrOx® G Self-stirring oxygen sensor for determination in Karlsruhe bottles and Winkler bottles with OxiCal®-ST calibration and storage vessel, 3 exchange membrane heads, electrolyte and abrasive foil. Note: Please order cleaning solution RL-G 205204 separately! |
1320 |
201533 |
Xylem WTW |
CellOx® 325 Galvanic oxygen sensor with OxiCal®-SL calibration and storage vessel, waterproof plug (IP 67), cable length 1.5m (4.9 ft), incl. abrasive foil, 3 exchange membrane heads and electrolyte. Note: Please order cleaning solution RL-G 205204 separately! |
1007 |
201545 |
Xylem WTW |
CellOx® 325-3 Galvanic oxygen sensor with OxiCal®-SL calibration and storage vessel, waterproof plug (IP 67), cable length 3 m (9.9 ft), incl. abrasive foil, 3 exchange membrane heads and electrolyte. Note: Please order cleaning solution RL-G 205204 separately! |
1046 |
201546 |
Xylem WTW |
CellOx® 325-6 Galvanic oxygen sensor with OxiCal®-SL calibration and storage vessel, waterproof plug (IP 67), cable length 6 m (19.8 f), incl. abrasive foil, 3 exchange membrane heads and electrolyte. Note: Please order cleaning solution RL-G 205204 separately! |
1081 |
201570 |
Xylem WTW |
DurOx 325-3 Galvanic oxygen sensor with OxiCal®-D calibration and storage vessel, waterproof plug (IP 67), cable length 9.9 ft (3 m), 1 exchange membrane head and electrolyte, abrasive foil. Note: Please order cleaning solution RL-G 205204 separately! |
740 |
201575 |
Xylem WTW |
SK-D Protective hood for DurOx® sensor. |
86 |
201578 |
Xylem WTW |
ZBK-D Accessory box with spare parts and maintenance supplies for DurOx® sensor, 3 exchange membrane heads and electrolyte, abrasive foil. Note: Please order cleaning solution RL-G 205204 separately! |
250 |
201579 |
Xylem WTW |
OxiCal® -D Calibration vessel for DurOx® sensors. |
198 |
202706 |
Xylem WTW |
ZBK 325 Accessory case with spare parts and maintenance supplies for oxygen sensors CellOx® 325, TA 197 Oxi, ConOx Ox module, abrasive foil, 3 exchange membrane heads and electrolyte. Note: Please order cleaning solution RL-G 205204 separately! |
244 |
202710 |
Xylem WTW |
ZBK ST Accessory box with spare parts and maintenance supplies for StirrOx® G oxygen sensors, abrasive foil, 3 exchange membrane heads and electrolyte. Note: Please order cleaning solution RL-G 205204 separately! |
251 |
202725 |
Xylem WTW |
WP 90/3 3 exchange membrane heads for all DO sensors, except StirrOx® G and DurOx® 325. |
176 |
202738 |
Xylem WTW |
WP3-ST 3 exchange membrane heads for StirrOx® G. |
185 |
202740 |
Xylem WTW |
WP3-D 3 exchange membrane heads for DurOx® sensors. |
178 |
203680 |
Xylem WTW |
SF 300 Cathode cleaner (abrasive foil) for WTW oxygen sensors of TriOxmatic® and CellOx® series |
35.9 |
203730 |
Xylem WTW |
D 201 Flow-through vessel for CellOx® 325 or TetraCon® 325 conductivity cell. |
524 |
203824 |
Xylem WTW |
RZ 300 Attachment stirrer for constant approach flow in combination with a magnetic stirrer. For CellOx® 325, FDO® 925. |
176 |
205204 |
Xylem WTW |
RL-G Cleaning solution for galvanic oxygen sensors StirrOx® G, CellOx® 325, DurOx® 325, TA 197 Oxi, ConOx and MPP 350 Ox module, 1 bottle with 30 ml. |
71 |
205210 |
Xylem WTW |
ELY/N Electrolyte for amperometric oxygen sensors, 1 bottle with 50 ml. |
95 |
205217 |
Xylem WTW |
ELY/G Electrolyte for galvanic oxygen sensors StirrOx® G, CellOx® 325, DurOx® 325, TA 197 Oxi ConOx and MPP 350 Ox module, 1 bottle with 50 ml. |
82 |
205348 |
Xylem WTW |
Sta-ST Stand base for OxiCal®-ST calibration and storage vessel for StirrOx® G oxygen sensor. |
75 |
205349 |
Xylem WTW |
OxiCal® -ST Calibration and storage vessel for StirrOx® G for precision calibration in water vapor saturated air. |
208 |
205362 |
Xylem WTW |
OxiCal® -SL Standard calibration and storage sleeve for precision calibration in water vapor saturated air. |
206 |
205700 |
Xylem WTW |
KF 12 Karlsruhe bottles, incl. 60 mm ground stoppers suitable for BOD determination. Minimum order 10 bottles. |
50 |
205710 |
Xylem WTW |
TS 19 Funnel set for BOD determination in NS 19 Winkler bottles. |
237 |
205711 |
Xylem WTW |
FD 19/KA Fixing cover for Karlsruher bottle KF 12. |
122 |
205712 |
Xylem WTW |
FR 19 Fixing ring, recommended for measurements in Karlsruhe bottles for CellOx® 325 or FDO® 925 |
106 |
208140 |
Xylem WTW |
IS 6 Stirrer for 6 measuring units, universal power supply 100 to 240 VAC, 50/60 Hz; |
932 |
208141 |
Xylem WTW |
IS 12 Stirrer for 12 measuring units, universal power supply 100 to 240 VAC, 50/60 Hz; |
1464 |
208145 |
Xylem WTW |
IS 6-Var Stirrer for 6 sample or measuring vessels PF../MF.. or MG.. with base diameter up to 93 mm, universal power supply 100 to 240 VAC, 50/60 Hz |
1644 |
208260 |
Xylem WTW |
OxiTop®-i IS 6 BOD instrument for self-check with 6 measuring units, with direct display of the BOD value at the measuring head, universal power supply 100 to 240 VAC, 50/60 Hz; accessories: see table Composition of complete packages. Please order sodium hydroxide pellets NHP 600 separately! |
3069 |
208262 |
Xylem WTW |
OxiTop®-i IS 12 BOD instrument for self-check with 12 measuring units, with direct display of the BOD value at the measuring head, universal power supply 100 to 240 VAC, 50/60 Hz; accessories: see table "Composition of complete packages". Please order sodium hydroxide pellets NHP 600 separately! |
5290 |
208264 |
Xylem WTW |
OxiTop®-i SET 2 SET for 2 measuring units, complete with 2 OxiTop®-i measuring heads (1 x blue, 1 x grey), including 2 sample bottles PF600, 2 rubber sleeves GK 600 and 2 magnetic stirring bars RST 600. |
744 |
208266 |
Xylem WTW |
OxiTop®-i SET 6 SET for 6 measuring units, complete with 6 OxiTop®-i measuring heads (3 x blue, 3 x grey), including 6 sample bottles PF600, 6 rubber sleeves GK 600 and 6 magnetic stirring bars RST 600. |
2096 |
208270 |
Xylem WTW |
OxiTop®-i G OxiTop®-i measuring head (grey), menu-operated, with backlit graphic LCD, control LED, operating buttons, for direct BOD readings, volume pre-selection, measurement duration between 1 and 7 days selectable, display of measuring curve, display of current readings. |
386 |
208272 |
Xylem WTW |
OxiTop®-i B OxiTop®-i measuring head blue, menu-operated, with backlit graphic LCD, control LED, operating buttons, for direct BOD readings, volume pre-selection, measurement duration between 1 and 7 days selectable, display of measuring curve, display of current readings. |
386 |
208274 |
Xylem WTW |
OxiTop®-i 2 2 OxiTop®-i measuring heads (blue and grey), menu-operated, with backlit graphic LCD, control LED, operating buttons, for direct BOD readings, volume pre-selection, measurement duration between 1 and 7 days selectable, display of measuring curve, display of current readings. |
724 |
208276 |
Xylem WTW |
OxiTop®-i 6 6 OxiTop®-i measuring heads (3 x blue and 3 x grey), menu-operated, with backlit graphic LCD, control LED, operating buttons, for direct BOD readings, volume pre-selection, measurement duration between 1 and 7 days selectable, display of measuring curve, display of current readings. |
2020 |
208278 |
Xylem WTW |
OxiTop®-i 12 12 OxiTop®-i measuring heads (6 x blue and 6 x grey), menu-operated, with backlit graphic LCD, control LED, operating buttons, for direct BOD readings, volume pre-selction, measurement duration between 1 and 7 days selectable, display of measuring curve, display of current readings. |
3966 |
208432 |
Xylem WTW |
OxiTop® Box BOD OxiTop® thermostat box, for max. 12 OxiTop® units/20 Karlsruhe bottles for IS/6 / IS/12 stirrer, 230 VAC, 50 Hz. |
3377 |
208450 |
Xylem WTW |
TS 608/2-i Incubator cabinet for 2 BOD OxiTop® systems (12 standard bottles each), 230 VAC, 50 Hz, refrigerant R-600a. |
2238 |
208452 |
Xylem WTW |
TS 608-G/2-i Incubator cabinet for 2 BOD OxiTop® systems (12 standard bottles each), with insulating glass front door, 230 VAC, 50 Hz, refrigerant R-600a. |
2528 |
208464 |
Xylem WTW |
TS 700/4-i Incubator cabinet for 4 BOD OxiTop® systems (12 standard bottles each), 230 VAC, 50 Hz, refrigerant R-600a. |
3066 |
208466 |
Xylem WTW |
TS 700-G/4-i Incubator cabinet for 4 BOD OxiTop® systems (12 standard bottles each), with insulating glass front door, 230 VAC, 50 Hz, refrigerant R-600a. |
3267 |
208468 |
Xylem WTW |
TS 1010-i Incubator cabinet for 4 BOD OxiTop® systems, special applications with large compartment height for 1.5 l flasks/bottles with nozzle, 230 VAC, 50 Hz, refrigerant R-600a. |
3765 |
209016 |
Xylem WTW |
OxiTop® AD/SK Adapter for OxiTop®-IDS / OxiTop®-C measuring heads for all sample and measuring bottles models PF45/..and MF/45, suitable for autoclave (incl. OxiTop® AD adapter, OxiTop® SK screwable adapter, gasket DI 45 for adapter, screwing set VS 45 for adapter, 2x GK 600 rubber sleeves). |
129 |
209019 |
Xylem WTW |
MG 1,0 Measuring vessel 1000 ml for OxiTop®-C/-IDS. Accessories: 1x DV/MG adapter with rack and gasket, 2x rubber sleeves GK 600, 4x DV/MG/KL clamps and 1x MB 50 measuring beaker (50 ml). |
191 |
209022 |
Xylem WTW |
DV/MG Cover adapter for measuring vessels MG 1.0 and MG 1.5 complete with holder and seal DV/MG/DI. |
182 |
209023 |
Xylem WTW |
MG 2,5 Measuring vessel for OxiTop®-C/-IDS with 2.5 l volume, accessories 1x V/MG lid adapter with rack and seal, 2x GK 600 rubber sleeve, 4x DV/MG/KL clamps and beaker MB 50 (50 ml). |
220 |
209030 |
Xylem WTW |
MK 22/600 Overflow measuring flask, contents 22.7 ml |
42.4 |
209040 |
Xylem WTW |
MK 43/600 Overflow measuring flask, contents 43.5 ml |
42.4 |
209050 |
Xylem WTW |
MK 97/600 Overflow measuring flask, contents 97.0 ml |
42.4 |
209060 |
Xylem WTW |
MK 164/600 Overflow measuring flask, contents 164 ml |
42.4 |
209070 |
Xylem WTW |
MK 250/600 Overflow measuring flask, contents 250 ml |
52 |
209080 |
Xylem WTW |
MK 365/600 Overflow measuring flask, contents 365 ml |
61 |
209090 |
Xylem WTW |
MK 432/600 Overflow measuring flask, contents 432 ml |
64 |
209100 |
Xylem WTW |
PF 600 Sample bottle, amber, contents 510 ml, minimum order 3 pcs, price per piece. |
9.2 |
209102 |
Xylem WTW |
PF45/250 Sample bottle, contents: 250 ml; Minimum order 3 pieces (packing unit), price per piece. |
16.8 |
209103 |
Xylem WTW |
PF45/500 Sample bottle, contents: 500 ml; Minimum order 3 pieces (packing unit), price per piece. |
22.9 |
209104 |
Xylem WTW |
PF45/1000 Sample bottle, contents: 1000 ml; Minimum order 3 pieces (packing unit), price per piece. |
30.5 |
209106 |
Xylem WTW |
MF45/250 Measuring bottle, contents: 250 ml with 2 nozzles incl. 2x VS 25 screwing sets for nozzle, 1x GK 600 rubber sleeve, 2x SEP 25 Septum for nozzle 2x STH 25 support for nozzle. |
186 |
209107 |
Xylem WTW |
MF45/500 Measuring bottle, contents: 500 ml with 2 nozzles incl. 2x VS 25 screwing sets for nozzle, 1x GK 600 rubber sleeve, 2x SEP 25 Septum for nozzles, 2x STH 25 support sleeves for nozzle. |
200 |
209108 |
Xylem WTW |
MF45/1000 Measuring bottle, contents: 1000 ml with 2 nozzles incl. 2x VS 25 screwing sets, 2x SEP 25 Septum for nozzles, 2x STH 25 support sleeves for nozzle. |
212 |
209110 |
Xylem WTW |
MF45/250/E Spare measuring bottle, contents 250 ml. |
163 |
209111 |
Xylem WTW |
MF45/500/E Spare measuring bottle, contents 500 ml. |
182 |
209112 |
Xylem WTW |
MF45/1000/E Spare measuring bottle, cont. 1000 ml. |
190 |
209120 |
Xylem WTW |
RST 600 Stirrer bar, minimum order 3 pcs, price per piece. |
10 |
209130 |
Xylem WTW |
REF 600 Stirrer bar remover. |
51 |
209140 |
Xylem WTW |
NHP 600 Sodium hydroxide pellets, 2 bottles of 50 g each. |
66 |
209142 |
Xylem WTW |
NKI 500 Soda lime as CO2 absorbant, with indicator, 500 g. |
142 |
209172 |
Xylem WTW |
GK 600 L Rubber sleeve L for OxiTop® systems usable with PF 600 and MG 1,0 with DV/MG adapter. |
11.5 |
209331 |
Xylem WTW |
NTH 600 Nitrification inihibitor, light protected bottle with content 25 ml. Concentration 5 g/l allylthiourea |
46.5 |
209333 |
Xylem WTW |
OxiTop® PM System check of OxiTop® systems with 10 calibration tablets for checking measuring units (long term test of leakage testing and negative pressure). |
77 |
209334 |
Xylem WTW |
OxiTop® PT Check unit for negative pressure and leakage testing for all OxiTop® measuring heads. |
206 |
209500 |
Xylem WTW |
VS 45 Screw connection for adapter OxiTop® AD/SK /OxiTop® AD; minimum order 3 pieces (packing unit), price per piece. |
12.8 |
209501 |
Xylem WTW |
DI 45 Seal for OxiTop® AD/SK / OxiTop® AD adapter suitable for autoclave (121°C); minimum order 5 pieces (packing unit), price per piece. |
7.1 |
209502 |
Xylem WTW |
VS 25 Screwable connection for nozzle of measuring vessels MF45/…, suitable for autoclave, minimum order 5 pieces (packing unit), price per piece. |
8 |
209503 |
Xylem WTW |
SEP 25 Septum for nozzle of measuring vessels MF45/…, suitable for autoclave (121°C), minimum order 5 pieces (packing unit), price per piece. |
6.9 |
209504 |
Xylem WTW |
STH 25 Supporting sleeve for nozzle of measuring vessels MF45/..., suitable for autoclave (121°C), minimum order 5 pieces (packing unit), price per piece. |
17 |
209510 |
Xylem WTW |
MG 1,0 E Replacement measuring vessel 1000 ml, minimum order 6 pcs, price per piece. |
12.6 |
209512 |
Xylem WTW |
MG 2,5 E Replacement vessel MG 2.5, minimum order 4 units, price per unit. |
24.1 |
209520 |
Xylem WTW |
DV/MG/KL Clip for measuring vessel MG 1.0, minimum order 20 pcs, price per piece. |
4.4 |
209521 |
Xylem WTW |
DV/MG/DI Seal for measuring vessel MG 1.0 and MG 2.5, minimum order 5 pcs, price per piece. |
11.3 |
209700 |
Xylem WTW |
OxiTop®-IDS OxiTop®-IDS wireless measuring head with Bluetooth® LE technology for operation with Multi 3620 IDS or Multi 3630 IDS, memory for 360 measuring points, with backlit graphic LCD and control LED, for routine BOD also operable without IDS multi-parameter instrument. |
516 |
209701 |
Xylem WTW |
OxiTop®-IDS/B OxiTop®-IDS/B wireless measuring head with Bluetooth® LE technology for operation with Multi 3620 IDS or Multi 3630 IDS, memory for 360 measuring points, with backlit graphic LCD and control LED, enhanced pressure range up to 1.5 bars, H2S resistant pressure sensor for biogas measurement, for routine BOD also operable without IDS multi-parameter instrument. |
552 |
209702 |
Xylem WTW |
OxiTop®-IDS 2 Two OxiTop®-IDS wireless measuring heads with Bluetooth® LE technology for operation with Multi 3620 IDS or Multi 3630 IDS, memory for 360 measuring points, with backlit graphic LCD and control LED, for routine BOD also operable without IDS multi-parameter instrument. |
986 |
209704 |
Xylem WTW |
OxiTop®-IDS 6 Six OxiTop®-IDS wireless measuring heads with Bluetooth® LE technology for operation with Multi 3620 IDS or Multi 3630 IDS, memory for 360 measuring points, with backlit graphic LCD and control LED, for routine BOD also operable without IDS multiparameter instrument. |
2959 |
209711 |
Xylem WTW |
OxiTop®-IDS Set 6 Respirometric measuring system for aerobic measuring, also for BOD self check measurements, 6 measuring units, requires Multi 3620 IDS SET WL or Multi 3630 IDS SET WL, please order separately. Universal power supply 100 to 240 VAC, 50/60 Hz. Accessories: see table "Composition of complete packages", incl. stirring platform IS 6. Please order CO2 absorber NHP 600 separately. |
4102 |
209713 |
Xylem WTW |
OxiTop®-IDS Set 12 Respirometric measuring system for aerobic measuring, also for BOD self check measurements, 12 measuring units, requires Multi 3620 IDS SET WL or Multi 3630 IDS SET WL, please order separately. Universal power supply 100 to 240 VAC, 50/60 Hz. Accessories: see table "Composition of complete packages", incl. stirring platform IS 12. Please order CO2 absorber NHP 600 separately. |
7191 |
209714 |
Xylem WTW |
OxiTop®-IDS IS 6 Extension set for respirometric aerobic OxiTop®-IDS measurement systems (also for BOD self check measurements), stirring platform IS 6 for 6 measuring units, universal power supply 100 to 240 VAC, 50/60 Hz; accessories: including 6 sample bottles, 6 OxiTop®-IDS measuring heads, 6 rubber sleeves and 6 magnetic stirring bars. Without NTH 600, NHP 600 and overflow measuring flasks. |
3961 |
209716 |
Xylem WTW |
OxiTop®-IDS IS 12 Extension set for respirometric aerobic OxiTop®-IDS measurement systems (also for BOD self check measurements), stirring platform IS 12 for 12 measuring units, universal power supply 100 to 240 VAC, 50/60 Hz; accessories: including 12 sample bottles, 12 OxiTop®-IDS measuring heads, 12 rubber sleeves and 12 magnetic stirrer bars. Without NTH 600, NHP 600 and overflow measuring flasks. |
7049 |
209721 |
Xylem WTW |
OxiTop®-IDS A6 Respirometric measuring system for aerobic operation, 6 measuring units, requires Multi 3620 IDS SET WL or Multi 3630 IDS SET WL, please order separately. Universal power supply 100 to 240 VAC, 50/60 Hz. Accessories: see table "Composition of complete packages", incl. 6 sample bottles, PF45/1000 (1000 ml), 6 OxiTop® AD/SK adapters and 1 stirring platform IS 6-Var. Please order CO2 absorber NHP 600 separately. |
5468 |
209723 |
Xylem WTW |
OxiTop®-IDS A12 Respirometric measuring system for aerobic operation, 12 measuring units, requires Multi 3620 IDS SET WL or Multi 3630 IDS SET WL, please order separately. Universal power supply 100 to 240 VAC, 50/60 Hz. Accessories: see table "Composition of complete packages", incl. 12 sample bottles, PF45/250 (250 ml), 12 OxiTop® AD/SK adapters and 1 stirring platform IS 12. Please order CO2 absorber NHP 600 separately. |
8517 |
209725 |
Xylem WTW |
OxiTop®-IDS AN6 Respirometric measuring system for anaerobic operation, 6 measuring units, requires Multi 3620 IDS SET WL or Multi 3630 IDS SET WL, please order separately. Universal power supply 100 to 240 VAC, 50/60 Hz. Accessories: see table "Composition of complete packages", incl. 6 MF45/1000 bottles (1000 ml) with 2 nozzles each and septum seal, 6 OxiTop® AD/SK adapters and 1 stirring platform IS 6-Var. Please order CO2 absorber NHP 600 separately. |
6139 |
209727 |
Xylem WTW |
OxiTop®-IDS AN12 Respirometric measuring system for anaerobic operation, requires IDS multiparameter instrument Multi 3620 IDS Set WL or Multi 3630 IDS Set WL, 12 measuring units, universal power supply 100 to 240 VAC, 50/60 Hz. Universal power supply 100 to 240 VAC, 50/60 Hz. Accessories: see table "Composition of complete packages", incl. 12 MF45/250 bottles (250 ml) with 2 nozzles each and septum seal, 12 OxiTop® AD/SK adapters and 1 stirring platform IS 12. Please order CO2 absorber NHP 600 separately. |
10195 |
209729 |
Xylem WTW |
OxiTop®-IDS B6 Measuring system for determination of soil respiration (aerobic), 6 measuring units, requires Multi 3620 IDS SET WL or Multi 3630 IDS SET WL, please order separately. Accessories: see table "Composition of complete packages", incl. 6 bottles PF45/500 of 500 ml each and 6 OxiTop® AD/SK adapters. Please order CO2 absorber NHP 600 separately. |
3822 |
209731 |
Xylem WTW |
OxiTop®-IDS B6M Measuring system for determination of soil respiration (aerobic) , 6 measuring units with 1.0 l measuring vessels, requires Multi 3620 IDS SET WL or Multi 3630 IDS SET WL, please order separately. Accessories: see table "Composition of complete packages", including 6 vessels MG 1.0, each including lid adapter DV/MG, DV/MG/KL clamps, GK 600 rubber sleeve and beaker MB 50. Please order CO2 absorber NHP 600 separately. |
4049 |
209732 |
Xylem WTW |
OxiTop®-IDS B6M-2.5 Measuring system for determination of soil respiration according AT4 (aerobic) requires IDS multiparameter instrument Multi 3620 IDS and 6 measuring units with 2.5 l measuring vessels. Accessories: see table "Composition of complete packages", including 6 vessels MG 2.5, each including lid adapter DV/MG, DV/MG/KL clamps, GK 600 rubber sleeve and beaker MB 50, CO2 absorbent. |
4349 |
250049 |
Xylem WTW |
P 3002 Thermal printer with paper width 112 mm for paper RP P3001. With USB and RS 232 interface. Works with MultiLine® Multi 3620/3630 IDS,inolab® Multi 9620/9630 IDS and instuments with RS 232 interface of Series Turb® 750/430/photoFlex®. For these instruments cable AK 540/S (902843) is required. |
765 |
250100 |
Xylem WTW |
TFK CR External temperature sensor for AQA temperature monitoring for CR 3200 and CR 4200 thermoreactors. |
345 |
250101 |
Xylem WTW |
AK CR/P Printer connection cable for CR 2200, CR 3200 and CR 4200 thermoreactors |
320 |
250102 |
Xylem WTW |
AK CR/PC PC connection cable for CR 2200, CR 3200 and CR 4200 thermoreactors. |
250 |
250113 |
Xylem WTW |
RP P 3001 Printer paper for P 3001/3002 and inoLab® printer, thermal paper legible for approx. 7 years, width 112 mm. |
12.6 |
250115 |
Xylem WTW |
RP 58 HQ Quality thermal printer paper for für inoLab® 7310P/9310P. Width 58 mm, 9 length 9 m. Long lasting readability. |
17.3 |
250203 |
Xylem WTW |
photoLab 7100 VIS Spectrophotometer (VIS) for spectral and routine analysis in the range of 320 - 1100 nm (reference beam) from water to wine and science. AQA-Support, complex programming options for user-defined programs, multiwavelength methods, kinetics and spectra, 2 USB interfaces, universal power supply with car adapter option for onsite measurements. More than 230 programs for test kits (16 mm round cells and 10, 20, 50 mm rectangluar cuvettes) with barcode- and automatic cell recognition for all cuvette sizes as well as approx. 50 reagent free application programs. PC-Software photoLab®Data spectral for GLP-compliant data management is included. Optional: PC-Software photoLab color® for comprehensive color measurement |
4992 |
250204 |
Xylem WTW |
photoLab 7600 UV-VIS Spectrophotometer (UV/VIS) reference beam for spectral and routine analysis in the range of 190 - 1100 nm from water to wine and science. With optical reagent-free measurement OptRF of COD, Nitrite and Nitrate, AQA-Support, complex programming options for user-defined programs, multiwavelength methods, kinetics and spectra, USB + Ethernet interfaces, universal power supply with car adapter option for onsite measurements. More than 250 programs for test kits (16 mm round cells and 10, 20, 50 mm rectangluar cuvettes) with barcode- und automatic cell recognition for all cuvette sizes as well as approx. 50 reagent free application programs.PC-Software photoLab®Data spectral for GLP-compliant data management is included. Optional: PC-Software photoLab color® for comprehensive color measurement. |
8008 |
250212 |
Xylem WTW |
FC spectral 6/7 Field case for photoLab® 6000 & 7000 with foam insert, not equipped, meas. WxHxD 280x460x580 mm. |
505 |
250213 |
Xylem WTW |
PL6-10 SIC Holder for 10 mm cuvettes |
70 |
250214 |
Xylem WTW |
PL6-BREW Brewery application package according to MEBAK (EBC/DIN) for photoLab® 6000 & 7000 Series |
492 |
250215 |
Xylem WTW |
LM spectral 7100 Spare lamp modul for photoLab® 7100 VIS |
119 |
250301 |
Xylem WTW |
CSB 09772 Hg-frei |
137 |
250303 |
Xylem WTW |
CSB 14560 COD Chemical Oxygen Demand O2 |
124.9 |
250304 |
Xylem WTW |
CSB 14690 |
124.9 |
250306 |
Xylem WTW |
CSB 09773 Hg-frei |
137 |
250309 |
Xylem WTW |
CSB 14555 |
124.9 |
250313 |
Xylem WTW |
Pb 14833 |
140 |
250314 |
Xylem WTW |
Cd 14834 |
140 |
250329 |
Xylem WTW |
NH4 / NH3 14544 |
137 |
250331 |
Xylem WTW |
HCHO 14678 |
220.5 |
250341 |
Xylem WTW |
Cr 14552 |
149.2 |
250344 |
Xylem WTW |
CN 14561 |
162.7 |
250347 |
Xylem WTW |
NO3-N 14764 |
144.2 |
250349 |
Xylem WTW |
Fe 14549 |
128.1 |
250351 |
Xylem WTW |
CSB 14691 |
124.9 |
250353 |
Xylem WTW |
Cl 14730 |
121 |
250358 |
Xylem WTW |
Ntot 14537 |
184 |
250359 |
Xylem WTW |
COD 14895 |
124.9 |
250361 |
Xylem WTW |
Fe 14896 |
137 |
250402 |
Xylem WTW |
H2O2 14731 |
162 |
250403 |
Xylem WTW |
O2 14694 |
182 |
250404 |
Xylem WTW |
RH/Ca 14683 |
147.5 |
250406 |
Xylem WTW |
HCHO 14500 |
125.5 |
250407 |
Xylem WTW |
K 14562 |
158.5 |
250408 |
Xylem WTW |
Cu 14553 |
129.3 |
250409 |
Xylem WTW |
Ni 14554 |
139.1 |
250410 |
Xylem WTW |
NO3-N 14542 |
161.5 |
250411 |
Xylem WTW |
NO3-N 14556 |
178.8 |
250412 |
Xylem WTW |
Phenol 14551 |
129.9 |
250413 |
Xylem WTW |
PO4-P 14546 |
131.8 |
250414 |
Xylem WTW |
SO4 14548 |
125.5 |
250415 |
Xylem WTW |
SO4 14564 |
125.5 |
250416 |
Xylem WTW |
SO3 14394 |
129.5 |
250417 |
Xylem WTW |
Zn 14566 |
143.5 |
250419 |
Xylem WTW |
Cl2 00595 |
103.5 |
250420 |
Xylem WTW |
Cl2 00597 |
103.5 |
250421 |
Xylem WTW |
NO3-N 09713/1 |
187.9 |
250422 |
Xylem WTW |
NO3-N 14942 |
157.3 |
250424 |
Xylem WTW |
NH4-N 14559 |
125.5 |
250425 |
Xylem WTW |
Al 14825 |
207.5 |
250426 |
Xylem WTW |
NH4 / NH3 14752/1 |
228.5 |
250427 |
Xylem WTW |
B 14839 |
348 |
250428 |
Xylem WTW |
Ca 14815 |
236.9 |
250433 |
Xylem WTW |
Cr 14758 |
208 |
250435 |
Xylem WTW |
Fe 14761/1 |
247.2 |
250436 |
Xylem WTW |
Au 14821 |
728 |
250438 |
Xylem WTW |
Si 14794 |
196.5 |
250439 |
Xylem WTW |
Fe 14761/2 |
111.1 |
250440 |
Xylem WTW |
NO2-N 14776/2 |
144.5 |
250441 |
Xylem WTW |
Cu 14767 |
216.2 |
250442 |
Xylem WTW |
Mn 14770/1 |
235.4 |
250443 |
Xylem WTW |
Ni 14785 |
192.4 |
250444 |
Xylem WTW |
NO3-N 14773 |
214.2 |
250445 |
Xylem WTW |
NO2-N 14776/1 |
246.4 |
250446 |
Xylem WTW |
PO4-P 14848/1 |
161.1 |
250447 |
Xylem WTW |
PO4-P 14842 |
170.1 |
250450 |
Xylem WTW |
S 14779 |
190.3 |
250451 |
Xylem WTW |
Zn 14832 |
298.2 |
250452 |
Xylem WTW |
Zn 06146 |
82.9 |
250460 |
Xylem WTW |
SL Al 19770 |
48.3 |
250461 |
Xylem WTW |
SL NH4 19812 |
46.2 |
250462 |
Xylem WTW |
SL Pb 119776 |
47.9 |
250463 |
Xylem WTW |
SL B 19500 |
49 |
250464 |
Xylem WTW |
SL Cd 19777 |
47.6 |
250465 |
Xylem WTW |
SL Ca 19778 |
46.2 |
250466 |
Xylem WTW |
SL Cl 119897 |
45.9 |
250467 |
Xylem WTW |
SL Cr 19779 |
45.3 |
250468 |
Xylem WTW |
SL CrO3 19780 |
48.4 |
250469 |
Xylem WTW |
SL Fe 19781 |
45.9 |
250470 |
Xylem WTW |
SL F 119814 |
44.3 |
250473 |
Xylem WTW |
SL Cu 19786 |
47.9 |
250474 |
Xylem WTW |
SL Mn 19789 |
49 |
250475 |
Xylem WTW |
SL Ni 119792 |
49.5 |
250476 |
Xylem WTW |
SL NO3 119811 |
48.7 |
250477 |
Xylem WTW |
SL NO2 19899 |
47.5 |
250478 |
Xylem WTW |
SL PO4 19898 |
45.9 |
250479 |
Xylem WTW |
SL Ag 119797 |
49 |
250480 |
Xylem WTW |
SL SO4 19813 |
47 |
250481 |
Xylem WTW |
SL Zn 119806 |
47.6 |
250482 |
Xylem WTW |
CombiCheck 10 14676 |
106 |
250483 |
Xylem WTW |
CombiCheck 20 14675 |
108 |
250486 |
Xylem WTW |
CombiCheck 50 14695 |
119 |
250487 |
Xylem WTW |
CombiCheck 60 14696 |
149.8 |
250488 |
Xylem WTW |
CombiCheck 70 14689 |
120.4 |
250489 |
Xylem WTW |
CombiCheck 80 14738 |
143 |
250490 |
Xylem WTW |
PhotoCheck 14693 Testing equipment for AQA of optics and linearity of photoLab® S6/S12 and photoLab® 6000/7000 Series. Set of colour solutions in 16 mm round vials |
435 |
250491 |
Xylem WTW |
Cl 14897/1 |
148.4 |
250492 |
Xylem WTW |
CN 09701 |
162.7 |
250493 |
Xylem WTW |
N2H4 09711 |
112.5 |
250494 |
Xylem WTW |
Nges 14763 |
169.2 |
250495 |
Xylem WTW |
NH4-N 14739 |
127.7 |
250496 |
Xylem WTW |
Crack-Set 10 14687 Crack set 10 for thermal digestion of heavy metals, sufficient for 100 digestions, requires empty 16 mm round cells (250 621) |
163.4 |
250497 |
Xylem WTW |
Crack-Set 20 14963 Crack set 20 for Nitrate (14563, 14542 and 14773) for 90 determinations of total nitrogen in sample materials containing at most 15 mg/l N, requires empty 16 mm round cells (250 621) |
163.7 |
250498 |
Xylem WTW |
PipeCheck 14962 Testing equipment - AQA for pipette volume |
475 |
250499 |
Xylem WTW |
SL TOC 09017 |
135 |
250536 |
Xylem WTW |
LP 6/12 Spare lamp for photoLab® S6/S12. |
83 |
250545 |
Xylem WTW |
KHP/Var 1000 Variable piston pipette 100 - 1000 µl (setting adjustable in 1 µl steps). |
447 |
250546 |
Xylem WTW |
KHP/Var 5000 Variable piston pipette 0.5 - 5 ml with (setting adjustable in 10 µl steps). |
459 |
250567 |
Xylem WTW |
PSP/Var 5 200 precision disposable pipette tips (colorless) for piston pipettes KHP/ETP 5000 (500 - 5000 µl) and KHP 2 (2 ml). |
68 |
250570 |
Xylem WTW |
SPB 500 precision tips for pipette (blue) for models KHP 02, 05, 1 and KHP/ETP VAR 1000. |
71 |
250579 |
Xylem WTW |
KS 2-12 Acryl Cuvette holder, acrylic, 2x12 round cells. |
137 |
250600 |
Xylem WTW |
REK 20 2 rectangular cuvettes (pathlength 20 mm). |
146 |
250601 |
Xylem WTW |
REK 20 Quarz 1 rectangular cuvette quartz, layer thickness 20 mm. |
193 |
250605 |
Xylem WTW |
REK 10 2 rectangular cuvettes (pathlength 10 mm). |
77 |
250606 |
Xylem WTW |
REK 10 Quarz 1 rectangular cuvette quartz, layer thickness 10 mm. |
157 |
250607 |
Xylem WTW |
REC 10 PMMA Single use cell PMMA 10 mm, 100 pcs |
39 |
250614 |
Xylem WTW |
REK 50 1 rectangular cuvette (pathlength 50 mm). |
124 |
250615 |
Xylem WTW |
REK 50 Quarz 1 rectangular cuvette quartz, layer thickness 50 mm. |
295 |
250616 |
Xylem WTW |
REC 50/2 Half micro cell, optical glass (special), 50 mm, 1 pc. |
251 |
250621 |
Xylem WTW |
RK 14/25 25 round cuvettes, empty (16 mm diameter). |
93.6 |
250745 |
Xylem WTW |
AK 3000 Interface cable for connecting one instrument for which LQ 300 is recommended to P 3001. |
78 |
251100 |
Xylem WTW |
pHotoFlex® pH Portable LED multiparameter filter photometer/colorimeter with approx. 200 programs and 100 user-defined programs, 1000 data sets and full electro-chemical pH functions with optional Lab support via LabStation, single instrument; optional: rechargeable batteries (251 300) and LabStation with rech. batteries and software LSdata Flex/430 (251 301), PC-software LSdata Flex/430 (Stand-alone 902762), pH electrodes see catalog. |
2283 |
251105 |
Xylem WTW |
pHotoFlex® STD LED filter photometer with 6 wavelength, 50 user-defined methods, 100 data sets, optional lab use and data management via LabStation including LSdata Flex/430 software (251 301), PC-Software LSdata Flex/430 Stand-alone (902762). |
1866 |
251110 |
Xylem WTW |
pHotoFlex® Turb Portable LED multiparameter filter photometer with full electro-chemical pH functions and integrated IR turbidity measurement acc. DIN/ISO with approx. 200 programs and 100 user-defined programs, 100 data sets, optional Lab support via LabStation, single instrument with calibration standard kit ; optional: rechargeable batteries (251 300) or LabStation with rechargeable batteries and LSdata Flex/430 software (251 301), pH electrodes see catalog |
3018 |
251200 |
Xylem WTW |
pHotoFlex® pH/SET Portable LED filter photometer with integrated pH function in a field case with table insert for instrument, stand and cuvettes; pH electrode SenTix® 41. Accessories: empty cuvettes 16+28 mm, cleaning tissues, stand, buffer solutions pH 4.01 + 7.00, beaker, screw driver, PC-software LSdata Flex/430, PC cable AK 540 B, instructions. Not included: Pipette KK/VAR5000 with tips, adjustable, 0.5 - 5 ml. Please order separately (250546). |
2949 |
251205 |
Xylem WTW |
pHotoFlex® STD/SET Portable LED filter photometer with 6 wavelengths, 50 user-defined methods and 100 data sets, in a field case with table insert and accessories. Accessories: 2 syringes 2 and 10 ml each, empty vials 16+28 mm, cleaning tissues, screw driver, PC-software LSdata Flex/430, PC cable AK 540 B, instructions. |
2377 |
251210 |
Xylem WTW |
pHotoFlex® Turb/SET Portable LED filter photometer with integrated IR turbidity and pH measurement in a field case with table insert to hold instrument, stand and cuvettes; pH electrode SenTix® 41 . Accessories: empty cuvettes 16+28 mm, calibration kit for turbidity, cleaning tissues, stand, buffer solutions pH 4.01 + 7.00, beaker, screw driver, PC-software LSdata Flex/430, PC cable AK 540 B, instructions. Not included: Pipette KK/VAR5000 with tips, adjustable, 0.5 - 5 ml. Please order separately (250546) |
3715 |
251300 |
Xylem WTW |
RB Flex/430 Rechargeable battery with universal plug for pHotoFlex® pH/ photoFlex® Turb and Turb® 430 IR/T. |
223 |
251301 |
Xylem WTW |
LS Flex/430 LabStation suitable for all pHotoFlex® and Turb® 430 models; for easy lab use with software package LSdata Flex/430 for GLP-compliant data handling, null modem cable, rechargeable batteries, universal plug including loading function, RS232 Interface. Use of bar code reader possible. |
525 |
251302 |
Xylem WTW |
LK 28-Set-12 12 empty cuvette for pHotoFlex® Series and Turb® 430 IR/T, 28x60 mm. |
70 |
251302S |
Xylem WTW |
LK28-Set-6 6 empty cuvette for pHotoFlex® Series and Turb® 430 IR/T, 28x60 mm. |
48 |
251304 |
Xylem WTW |
FC pHotoFlex/Turb 430 Field case with table insert to hold instrument, stand and cuvettes for easy field handling. Additional space to hold accessories and pipette. |
386 |
251306 |
Xylem WTW |
pHotoFlex® Check PhotoCheck for photoFlex® Serie: standard solutions for instrument check with certificate, on request only |
475 |
251400 |
Xylem WTW |
Al-1 TP |
193 |
251401 |
Xylem WTW |
Cl2-1 TP |
30.5 |
251402 |
Xylem WTW |
Cl2-2 TP |
30.5 |
251403 |
Xylem WTW |
Cu-1 TP |
53.1 |
251404 |
Xylem WTW |
Fe-1 TP |
42 |
251405 |
Xylem WTW |
Fe-2 TP |
29.9 |
251406 |
Xylem WTW |
Mn-1 TP |
76.5 |
251407 |
Xylem WTW |
Mo-1 TP |
130 |
251408 |
Xylem WTW |
NH4-1 TP |
214 |
251409 |
Xylem WTW |
NO2-1 TP |
47 |
251410 |
Xylem WTW |
PO4-1 TP |
49 |
251411 |
Xylem WTW |
Si-1 TP (LR) |
84 |
251412 |
Xylem WTW |
Si-2 TP (HR) |
94 |
251413 |
Xylem WTW |
SO4-1 TP |
42 |
251414 |
Xylem WTW |
Cl2-3 TP |
30 |
251415 |
Xylem WTW |
Cl2-4 TP |
30 |
251416 |
Xylem WTW |
N2H4-1 TR |
24 |
251417 |
Xylem WTW |
Mn-2 TP |
78 |
251418 |
Xylem WTW |
Mo-2 TP |
157 |
251420 |
Xylem WTW |
NO2-3 TP |
55 |
251421 |
Xylem WTW |
DEHA-1 TP |
145 |
251422 |
Xylem WTW |
Si-3 TP (HR) |
134 |
251423 |
Xylem WTW |
SO4-2 TP |
50 |
251987 |
Xylem WTW |
PO4-4 TC |
139.2 |
251988 |
Xylem WTW |
PO4-3 TC |
125 |
251989 |
Xylem WTW |
PO4-2 TC |
100 |
251990 |
Xylem WTW |
COD1 TC (LR) |
93.5 |
251991 |
Xylem WTW |
COD2 TC (MR) |
93.5 |
251992 |
Xylem WTW |
COD3 TC (HR) |
93.5 |
251993 |
Xylem WTW |
NO3-1 TC |
105 |
251994 |
Xylem WTW |
NO2-2 TC (LR+HR) |
90.2 |
251995 |
Xylem WTW |
Ntot1 TC (LR) |
181.5 |
251996 |
Xylem WTW |
Ntot2 TC (HR) |
190.4 |
251997 |
Xylem WTW |
NH4-2 TC (LR) |
121 |
251998 |
Xylem WTW |
NH4-3 TC (HR) |
121 |
252010 |
Xylem WTW |
Cl2 00598/1 |
250 |
252011 |
Xylem WTW |
Cl2 00598/2 |
90 |
252012 |
Xylem WTW |
Cl2 00599 |
87.5 |
252013 |
Xylem WTW |
Cl2 00602/1 |
98 |
252016 |
Xylem WTW |
O3 00607/1 |
98 |
252017 |
Xylem WTW |
ClO2 00608 |
135 |
252018 |
Xylem WTW |
Nges 00613 |
170.9 |
252019 |
Xylem WTW |
NO3-N 00614 |
146.9 |
252020 |
Xylem WTW |
K 00615 |
172.5 |
252021 |
Xylem WTW |
PO4-P 00616 |
139.7 |
252022 |
Xylem WTW |
SO4 00617 |
126.5 |
252023 |
Xylem WTW |
AOX 00675 |
245 |
252024 |
Xylem WTW |
AOX 00677 AOX Sample Preparation Set |
499 |
252025 |
Xylem WTW |
AOX 00678 AOX Accumulation Set |
172 |
252026 |
Xylem WTW |
AOX 00680 |
158 |
252027 |
Xylem WTW |
NH4-N 00683 |
162.8 |
252028 |
Xylem WTW |
BSB 00687 |
148.7 |
252029 |
Xylem WTW |
BSB 00688 Nutrient salt for 12x1L dilution water |
97.4 |
252030 |
Xylem WTW |
BSB 00718 |
133.7 |
252032 |
Xylem WTW |
BSB 14663 SRF Reaction bottles BOD (Vol. 50 ml, Ø = 4 cm, H = 9 cm) |
93 |
252033 |
Xylem WTW |
Crack-Set 10-C 14688 25 cuvettes with digestion reagents for thermal digestion of heavy metals in wastewater analysis. |
167.8 |
252034 |
Xylem WTW |
Pb 09717 |
147.8 |
252035 |
Xylem WTW |
Mn 00816 |
148.7 |
252036 |
Xylem WTW |
TOC 14878 |
388 |
252037 |
Xylem WTW |
TOC 14879 |
415 |
252038 |
Xylem WTW |
TOC 73500 Alu screw caps for TOC cuvette test; delivery: 6 pcs. |
129.5 |
252039 |
Xylem WTW |
GH/Ca 00961 |
141.4 |
252040 |
Xylem WTW |
Mo 00860 |
183.1 |
252041 |
Xylem WTW |
B 00826 |
187.2 |
252042 |
Xylem WTW |
Fe 00796 |
149.5 |
252043 |
Xylem WTW |
Mg 00815 |
148.7 |
252044 |
Xylem WTW |
Na 00885 |
170 |
252045 |
Xylem WTW |
PO4 00798 |
132.6 |
252046 |
Xylem WTW |
Si 00857 |
166.9 |
252047 |
Xylem WTW |
Ca 00858 |
170.1 |
252048 |
Xylem WTW |
F 14598/1 |
250 |
252049 |
Xylem WTW |
Zn 00861 |
156 |
252050 |
Xylem WTW |
pH 01744 |
117.5 |
252051 |
Xylem WTW |
Cd 01745 |
206.5 |
252053 |
Xylem WTW |
SO3 01746 |
208.6 |
252054 |
Xylem WTW |
O3 00607/2 |
304.1 |
252055 |
Xylem WTW |
CL2 00602/2 |
290 |
252057 |
Xylem WTW |
Monochloramin 01632 |
368 |
252058 |
Xylem WTW |
Phenol 00856 |
225.1 |
252061 |
Xylem WTW |
n-Ten 01787 |
173.5 |
252062 |
Xylem WTW |
c-Ten 01764 KT |
173.5 |
252063 |
Xylem WTW |
As 01747 |
470 |
252066 |
Xylem WTW |
As Absorptionsrohr 73501 Absorption tube for arsenic test, model 01747 |
82 |
252067 |
Xylem WTW |
H2O2 18789 |
204 |
252068 |
Xylem WTW |
Al 00594 |
132.5 |
252069 |
Xylem WTW |
NO2 00609 |
150 |
252070 |
Xylem WTW |
C3/25 |
124.9 |
252071 |
Xylem WTW |
C4/25 |
124.9 |
252072 |
Xylem WTW |
A6/25 |
128.4 |
252073 |
Xylem WTW |
N2/25 |
139.1 |
252074 |
Xylem WTW |
N5/25 |
128.4 |
252075 |
Xylem WTW |
P6/25 |
133 |
252076 |
Xylem WTW |
P7/25 |
133 |
252077 |
Xylem WTW |
Cl2-1 00086 |
53.5 |
252078 |
Xylem WTW |
Cl2-2 00087 |
56.7 |
252079 |
Xylem WTW |
Cl2-3 00088 |
85 |
252080 |
Xylem WTW |
Cl2 00089 Acc. |
88.1 |
252081 |
Xylem WTW |
NH4 / NH3 14752/2 |
147.6 |
252082 |
Xylem WTW |
Cl 14897/2 |
291.2 |
252083 |
Xylem WTW |
F 14598/2 |
665.6 |
252084 |
Xylem WTW |
Mn 14770/2 |
152.8 |
252085 |
Xylem WTW |
NO3-N 09713/2 RT |
342.4 |
252086 |
Xylem WTW |
PO4-P 14848/2 |
123 |
252087 |
Xylem WTW |
S/A Cap.pH4.3/CO2 01758 |
214.1 |
252089 |
Xylem WTW |
DEHA-Ox 19251 |
218.4 |
252091 |
Xylem WTW |
Cyanuric 19253 |
155.1 |
252092 |
Xylem WTW |
CSB 01796 |
135.2 |
252093 |
Xylem WTW |
CSB 01797 |
135.2 |
252094 |
Xylem WTW |
F 00809 |
134.2 |
252095 |
Xylem WTW |
Vol.Organic Acid 01809 |
267 |
252096 |
Xylem WTW |
Vol.Organic Acid 01749 |
192.4 |
252097 |
Xylem WTW |
Mn 01846 |
260 |
252102 |
Xylem WTW |
a-Ten 02552 KT 0,05 - 2,00 mg/l MBAS |
175 |
252103 |
Xylem WTW |
SO4 02537/1 |
208 |
252450 |
Xylem WTW |
SL COD 100 |
41.3 |
252451 |
Xylem WTW |
SL COD 400 |
41.3 |
252471 |
Xylem WTW |
SL K 70230 |
48.7 |
252472 |
Xylem WTW |
SL Si 70236 |
47.8 |
252501 |
Xylem WTW |
Combicheck 90 18700 |
143 |
252502 |
Xylem WTW |
Combicheck 100 18701 |
225 |
2AA110 |
Xylem WTW |
pH 3110 Easy-to-operate, robust pH/mV-meter with large LCD-Display, for portable routine measurement. Single instrument in a case including buffer STP 4 and STP 7, 3 mol/l KCl, short instruction manual, CD-ROM and batteries. |
615 |
2AA112 |
Xylem WTW |
pH 3110 SET 2 Easy-to-operate, robust pH/mV-meter with large LCD-display, for portable routine measurement, set with SenTix® 41. Meter in carry case with pH electrode SenTix® 41, buffer solution STP 4 and STP 7, stand, beaker, short instruction manual, CD-ROM and batteries. |
769 |
2AA310 |
Xylem WTW |
pH 3310 Professional, field proven pH/mV-meter with backlit graphic display, for portable application with data logger and USB interface. Single instrument in a case including buffer STP 4 and STP 7, 3 mol/l KCl, short instruction manual, CD-ROM and batteries, cable. |
761 |
2AA312 |
Xylem WTW |
pH 3310 SET 2 Professional, field proven pH/mV-meter with backlit graphic display, for portable application with data logger and USB interface, set including SenTix® 41. Meter in carry case with pH electrode SenTix® 41, buffer solution STP 4 and STP 7, stand, beaker, CD-ROM, driver software for USB, batteries, cable. |
985 |
2BA100 |
Xylem WTW |
Oxi 3205 Easy-to-operate, robust DO meter with backlit LCD graphic display, for routine measurement, single instrument. Single instrument in a case including short instruction manual, CD-ROM and batteries. |
792 |
2BA101 |
Xylem WTW |
Oxi 3205 SET 1 Easy-to-operate, robust DO meter with backlit LCD graphic display, for routine measurement, set including CellOx® 325. Meter with carry case including galvanic DO sensor CellOx® 325, electrolyte, exchange membrane heads, stand, beaker. Including short instruction manual, CD-ROM and batteries. Please order cleaning solution RL-G 205204 separately. |
1609 |
2BA300 |
Xylem WTW |
Oxi 3310 Professional, field proven DO meter with backlit graphic display for portable application including data logger and USB interface. Single instrument in a case including short instruction manual, CD-ROM and batteries. |
896 |
2BA301 |
Xylem WTW |
Oxi 3310 SET 1 Professional, field proven DO meter with backlit graphic display for portable application including data logger and USB interface, set including CellOx® 325. Meter with carry case including galvanic DO sensor CellOx® 325, electrolyte, 3 exchange membrane heads, stand, beaker. Including short instruction manual CD-ROM, batteries, driver software for USB, cable. Please order cleaning solution RL-G 205204 separately. |
1657 |
2CA100 |
Xylem WTW |
Cond 3110 Easy-to-operate, robust conductivity meter with large LCD-display, for routine field application, for 2- and 4-electrode cells. Single instrument in a case including 0.01 mol/l KCl standard solution, short instruction manual, CD-ROM and batteries. |
721 |
2CA101 |
Xylem WTW |
Cond 3110 SET 1 Easy-to-operate, robust conductivity meter with large LCD-Display, for routine field application, for 2- and 4-electrode cells, set including TetraCon® 325. Meter with carry case including 4-electrode conductivity cell TetraCon® 325, standard solution 1413 µS/cm at 25 °C, stand, beaker, short instruction manual, CD-ROM and batteries. |
1158 |
2CA300 |
Xylem WTW |
Cond 3310 Professional, field proven conductivity meter with backlit LCD-graphic display for field application including data logger, USB-interface. Single instrument in a case including 0.01 mol/l KCl standrad solution, short instruction manual, CD-ROM and batteries. |
844 |
2CA301 |
Xylem WTW |
Cond 3310 SET 1 Professional, field proven conductivity meter with backlit graphic display for field application including data logger, USB-interface. Meter with carry case including 4-electrode conductivity cell TetraCon® 325, standard solution 1413 µS/cm at 25 °C, stand, beaker, short instruction manual, CD-ROM and batteries, driver software for USB, cable. |
1297 |
2EA310 |
Xylem WTW |
pH/Cond 3320 Professional pH/conductivity meter with 2 inputs (DIN, 8 pin socket), backlit graphic display, for mobile application with data logger and USB interface. Single instrument in a case including short instruction manual, CD-ROM and batteries, cable. |
1260 |
2EA312 |
Xylem WTW |
pH/Cond 3320 SET 2 Professional pH/conductivity meter with 2 inputs (DIN, 8 pin socket), backlit graphic display, for mobile application with data logger and USB interface. meter in carry case including SenTix® 41, TetraCon® 325, buffer solution STP 4 and STP 7, conductivity standard 0.01 mol/l KCl. Instruction manual, stand, beaker, CD-ROM, driver software for USB, batteries, cable. |
1823 |
2F0001 |
Xylem WTW |
KS Universal Case set for for all analog and digital handhelds. Without meter and sensors, incl. armoring SM Pro, buffer STP 4 and STP 7, stand, beaker, conductivity standard 1413 µS/cm at 25° C. |
256 |
2F0004 |
Xylem WTW |
KS MultiLine® 2 Case set for MultiLine® multiparameter systems with 3 IDS sensors (large field case). Without meter and sensors, incl. armoring SM Pro, buffer STP 4 and STP 7, stand, beaker, conductivity standard 1413 µS/cm at 25° C. |
287 |
2FA310 |
Xylem WTW |
Multi 3320 Professional pH/dissolved oxygen/conductivity meter with 2 inputs (DIN, 8 pin socket), backlit graphic display, for mobile application with data logger and USB interface. Single instrument in a case including instruction manual, CD-ROM and batteries, cable |
1618 |
2FA311 |
Xylem WTW |
Multi 3320 SET 1 Professional pH/dissolved oxygen/conductivity meter with 2 inputs (DIN, 8 pin socket), backlit graphic display, for mobile application with data logger and USB interface. Meter in field case with SenTix® 41, CellOx® 325, TetraCon® 325, sensor accessories, instruction manual, stand, beaker, CD-ROM, armoring SM Pro, driver software for USB, batteries, cable. Please order cleaning solution RL-G 205204 separately. |
3045 |
2FA312 |
Xylem WTW |
Multi 3320 SET 2 Professional pH/dissolved oxygen/conductivity meter with 2 inputs (DIN, 8 pin socket), backlit graphic display, for mobile application with data logger and USB interface. Meter in field case with SenTix® 41-3, CellOx® 325-3, TetraCon® 325-3, sensor accessories, armoring SM Pro, instruction manual, stand, beaker, CD-ROM, driver software for USB, batteries, cable. Please order cleaning solution RL-G 205204 separately. |
3160 |
2FD350 |
Xylem WTW |
Multi 3510 IDS Professional multi-parameter handheld for IDS electrodes with single channel input. Wireless ready. With backlit display, built-in data logger and USB interface. Meter in a case including buffer 4 and 7, 0.01 mol/l KCl conductivity standard, short instruction manual, CD-ROM including software, batteries, USB cable. |
983 |
2FD351 |
Xylem WTW |
Multi 3510 IDS SET 1 Professional multi-parameter handheld for IDS electrodes. Wireless ready. With single cannel input, backlit display, built-in data logger and USB interface. Meter in case set including SenTix® 940 with short instruction manual, CD-ROM including software, batteries, USB cable. |
1262 |
2FD353 |
Xylem WTW |
Multi 3510 IDS SET 3 Professional multi-parameter handheld for IDS electrodes. Wireless ready. With single channel input, backlit display, built-in data logger and USB interface. Meter in case set includingTetraCon® 925 with short instruction manual, CD-ROM including software, batteries, USB cable. |
1568 |
2FD354 |
Xylem WTW |
Multi 3510 IDS SET 4 Professional multi-parameter handheld for IDS electrodes. Wireless ready. With single channel input, backlit display, built-in data logger and USB interface. Meter in case set including FDO® 925 with short instruction manual, CD-ROM including software, batteries, USB cable. |
1915 |
2FD35U |
Xylem WTW |
Multi 3510 IDS SET KS1 Professional digital multi meter for mobile measurement, single channel input, wireless ready, backlit display, including datalogger and USB interfaces, case set without sensor, instruction manual, stand, beaker, buffer 4 and 7, conductivitiy standard, CD-ROM, driver software for USB, batteries, USB cable, armoring SM Pro. |
1062 |
2FD560 |
Xylem WTW |
Multi 3620 IDS Professional digital multi meter for portable field measurement, with dual channel input, wireless ready, color graphic display incl. data logger and USB interfaces. Single instrumentin a case including buffer STP 4 and STP 7, 0.01 mol/l KCl conductivity standard, short instruction manual, CD-ROM, rechargeable batteries, driver software for USB, cable and universal power supply, protection SM Pro. |
1519 |
2FD56C |
Xylem WTW |
Multi 3620 IDS SET C Professional digital multi meter for portable field measurement, with dual channel input, wireless ready, color graphic display incl. data logger and USB interfaces. Multi case set with IDS sensors: digital pH electrode SenTix® 940, digital conductivity 4-electrode cell TetraCon® 925, QSC Kit (requires EUC), short instruction manual, stand, beaker, CD-ROM, driver software for USB, rechargeable batteries, cable, universal power supply, armoring SM Pro. |
2330 |
2FD56G |
Xylem WTW |
Multi 3620 IDS SET G Professional digital multi meter for portable field measurement, with dual channel input, wireless ready, color graphic display incl. data logger and USB interfaces. Field case set with IDS sensors: digital pH electrode SenTix® 940-3, digital conductivity cell TetraCon® 925-3, optical DO probe FDO® 925-3, QSC Kit (requires EUC), short instruction manual, stand, beaker, CD-ROM, driver software for USB, rechargeable batteries, cable, universal power supply, armoring SM Pro. |
3179 |
2FD56W |
Xylem WTW |
Multi 3620 IDS SET WL Professional digital multi meter for portable field measurement, with dual channel input, wireless ready, color graphic display including data logger and USB interfaces, also for controlling OxiTop®-IDS. Instrument with rechargeable batteries, driver software for USB, cable and universal power supply, protection SM Pro, and wireless meter module IDS WLM-M. |
1617 |
2FD570 |
Xylem WTW |
Multi 3630 IDS Professional digital multi meter for portable field measurement, with triple channel input, wireless ready, color graphic display incl. data logger and USB interfaces. Single instrument in a handy case including buffe rSTP 4 and STP 7, 0.01 mol/l KCl conductivity standard solution, short instruction manual, CD-ROM and rechargeable batteries, driver software for USB, cable, universal power supply, amoring SM Pro. |
2508 |
2FD57F |
Xylem WTW |
Multi 3630 IDS SET F Professional digital multi meter for portable field measurement, with triple channel input, wireless ready, color graphic display incl. data logger and USB interfaces. Field case set with IDS sensors: digital pH electrode SenTix® 940, digital conductivity cell TetraCon® 925, optical DO probe FDO® 925, buffers, QSC Kit (requires EUC), short instruction manual, stand, beaker, CD-ROM, driver software for USB, rechargeable batteries, cable, universal power supply, armoring SM Pro. |
4272 |
2FD57G |
Xylem WTW |
Multi 3630 IDS SET G Professional digital multi meter for portable field measurement, with triple channel input, wireless ready, color graphic display incl. data logger and USB interfaces. Field case set with IDS sensors: digital pH electrode SenTix® 940-3, digital conductivity cell TetraCon® 925-3, optical DO probe FDO® 925-3, buffers, QSC Kit (requires EUC), short instruction manual, stand, beaker, CD-ROM, driver software for USB, rechargeable batteries, cable, universal power supply, armoring SM Pro. |
4340 |
2FD57V |
Xylem WTW |
Multi 3630 IDS SET KS2 Professional digital multi meter for mobile measurement, triple channel input, colour graphic display including datalogger and USB interfaces, wireless ready. Field case set without sensor, including QSC-Kit (requires EUC), instruction manual, stand, beaker, buffer 4 and 7, 3 mol/l KCl, conductivity standard, CD-ROM, driver software for USB, rechargeable batteries, USB cable, power supply, armoring SM Pro. |
2573 |
2FD57W |
Xylem WTW |
Multi 3630 IDS SET WL Professional digital multi meter for portable field measurement, with triple channel input, wireless ready, color graphic display incl. data logger and USB interfaces, also for controlling OxiTop®-IDS. Instrument with rechargeable batteries, driver software for USB, cable and universal power supply, protection SM Pro, and wireless meter module IDS WLM-M. |
2582 |
2GA310 |
Xylem WTW |
pH/ION 3310 Professional pH/mV/ISE meter with DIN socket, backlit graphic display, for mobile application with data logger and USB interface. Single instrument in a case including instruction manual, CD-ROM and batteries, cable. |
1638 |
300572 |
Xylem WTW |
E-SET Trace Calibration set for conductivity measurement, 6 bottles with 50 ml calibration and control standard each, KCl 0.01 mol/l, traceable to PTB/NIST. |
142 |
300578 |
Xylem WTW |
KS 100 µS Calibration standard 100 µS/cm, shelf life 2 years, NIST traceable, accuracy ±3%. |
160 |
300580 |
Xylem WTW |
KS 5 µS Calibration standard 5 µS/cm, shelf life 1 year, NIST traceable, accuracy ±2%. |
304 |
301252 |
Xylem WTW |
TetraCon® DU/T 4-electrode flow-through conductivity cell with built-in temperature sensor, for all standard applications, cell constant: K = 0.778 cm-1 |
924 |
301254 |
Xylem WTW |
TetraCon® DU/TH 4-electrode flow-through conductivity cell with built-in temperature sensor, cell constant: K = 0.778 cm-1. |
984 |
301310 |
Xylem WTW |
LTA 1 2-electrode glass/platinum conductivity cell, cell constant K = approx. 1.0 cm-1, (Adapter cable K/LTA required). |
684 |
301429 |
Xylem WTW |
K-LTA Adapter cable for connection of 2-electrode conductivity cells and temperature sensors TFK 325 or TFK 150. |
235 |
301602 |
Xylem WTW |
TetraCon® 325 S 4-electrode-conductivity cell with built-in temperature sensor, 4.9 ft (1.5 m) cable and waterproof plug, cell constant K = 0.491 cm-1, |
714 |
301710 |
Xylem WTW |
TetraCon® 925 4-electrode-IDS conductivity cell with graphite electrodes, epoxy shaft, cell constant 0.475 cm–1, with 1.5 m fixed cable with waterproof digital connector. |
602 |
301711 |
Xylem WTW |
TetraCon® 925 -3 4-electrode-IDS conductivity cell with graphite electrodes, epoxy shaft, cell constant 0.475 cm–1, with 3 m fixed cable with waterproof digital connector. |
619 |
301716 |
Xylem WTW |
TetraCon® 925-P 4-electrodes IDS conductivity cell with graphite electrodes, epoxy shaft, cell constant 0.475 cm-1. Electrode with waterproof plug head for connection to a MPP IDS, wireless module or AS/IDS-x. |
622 |
301718 |
Xylem WTW |
TetraCon® 925/LV 4-electrode-IDS conductivity cell with graphite electrodes, epoxy shaft, cell constant 0.469 cm–1, fork design. With 1.5 m fixed cable with waterproof digital connector. For measurement of small volumes (about 2.5 ml) and viscous samples. |
756 |
301719 |
Xylem WTW |
TetraCon® 925/LV-P 4-electrode-IDS conductivity cell with graphite electrodes, epoxy shaft, cell constant 0.469 cm–1, fork design. with plug head for AS IDS/x cables or wireless module. For measurement of small volumes (about 2.5 ml) and viscous samples. |
777 |
301720 |
Xylem WTW |
LR 925/01 2-electrode-IDS conductivity cell with stainless steel electrodes for ultra pure water, cell constant 0.1 cm–1, with 1.5 m fixed cable with waterproof digital connector, glass flow trough vessel. |
833 |
301721 |
Xylem WTW |
TetraCon® 925/C 4-electrode-IDS conductivity cell with graphite electrodes, epoxy shaft, PEEK head for use in acid contaminated environments, cell constant 0.475 cm–1, with 1.5 m fixed cable with waterproof digital connector for MultiLine®, MonoLine or inoLab® IDS. |
869 |
301722 |
Xylem WTW |
LR 925/01-P 2-electrode-IDS conductivity cell with stainless steel electrodes, for ultrapure water, cell constant 0.1 cm–1, with plug head for AS/IDS-x cable or wireless module, glass flow through vessel. |
855 |
301900 |
Xylem WTW |
TetraCon® 325/C 4-electrode-conductivity cell with built-in temperature sensor, 1.5 m (4.5 ft) cable, water proof plug, cell constant K= 0.475 cm-1, for application in acidic environments, head made of PEEK. |
836 |
301960 |
Xylem WTW |
TetraCon® 325 4-electrode conductivity cell with built-in temperature sensor, 1.5 m (4.9 ft) cable and waterproof plug, cell constant K = 0.475 cm-1 |
563 |
301961 |
Xylem WTW |
LR 325/01 Ultrapure water conductivity cell with built-in temperature sensor and waterproof plug, cell constant K = 0.1 cm-1, glass flow-through vessel D01/T. |
698 |
301962 |
Xylem WTW |
LR 325/001 Trace conductivity cell with built-in temperature sensor, cable and waterproof plug, cell constant K = 0.01 cm-1, stainless steel flow-through vessel. |
1166 |
301963 |
Xylem WTW |
KKDU 325 Connection cable, 3.3 ft (1 m), 8-pin plug, for flow-through conductivity cells TetraCon® DU/T, TetraCon® DU/TH, KDU 1/T and KDU?1/TH |
179 |
301970 |
Xylem WTW |
TetraCon® 325-3 4-electrode conductivity cell with built-in temperature sensor, 3 m (9.8 ft) cable and waterproof plug, cell constant K = 0.475 cm-1. |
600 |
301971 |
Xylem WTW |
TetraCon® 325-6 4-electrode conductivity cell with built-in temperature sensor, 6 m (19.8 ft) cable and waterproof plug, cell constant K = 0.475 cm-1. |
633 |
301972 |
Xylem WTW |
TetraCon® 325-10 4-electrode conductivity cell with built-in temperature sensor, 10 m (33 ft) cable and waterproof plug, cell constant K = 0.475 cm-1. |
686 |
301973 |
Xylem WTW |
TetraCon® 325-15 4-electrode conductivity cell with built-in temperature sensor, 15 m (49 ft) cable and waterproof plug, cell constant K = 0.475 cm-1. |
750 |
301974 |
Xylem WTW |
TetraCon® 325-20 4-electrode conductivity cell with built-in temperature sensor, 20 m (65 ft) cable and waterproof plug, cell constant K = 0.475 cm-1. |
817 |
301995 |
Xylem WTW |
KLE 325 2-electrode conductivity cell with built-in temperature sensor and 1.5 m (4.9 ft) cable. Measuring range 1 µS/cm to 20 mS/cm. Temperature 0 to 80° C. Cell constant K=0.84 cm-1. |
428 |
302750 |
Xylem WTW |
D01/T Flow-through vessel, suitable for cond. cells LR 01/T, LTA 01 and LR 325/01, I.D. 18 mm V* = 1 ml (without sensor). |
206 |
302760 |
Xylem WTW |
D 001 Replacement flow through vessel for LR 325/001. |
317 |
302870 |
Xylem WTW |
6R/SET/LAB1 Test set for checking all conductivity meters with waterproof 8-pin socket according to ISO 9000. |
549 |
401205 |
Xylem WTW |
MPP 930 IDS Digital triple channel multi parameter sonde for IDS sensors. Designed for depth measurements to 100 m, including built-in pressure sensor. Sonde with guard, weight, protection caps for sensor inputs and sonde output. Including instruction manual, CD-ROM with software, 1.5 m connection cable AS/IDS-1.5. Needs Multi 3430/3630 IDS. |
3545 |
401206 |
Xylem WTW |
MPP 930-pH/FDO®/Cond Kit Digital triple channel multi parameter sonde for IDS sensors. Designed for depth measurements to 100 m, including built-in pressure sensor. Set for pH, conductivity and D.O. measurement. Sonde with guard, weight, protection caps for sensor inputs and sonde output. Including instruction manual, CD-ROM with software, 1.5 m connection cable AS/IDS-1.5. Set in a carry case including SensoLyt® 900-P, TetraCon® 925-P, FDO® 925-P, accessories. Needs Multi 3430/3630 IDS. |
6098 |
600120 |
Xylem WTW |
Turb 750 IR Laboratory turbidimeter with infrared LED according to DIN EN ISO 7027-1, universal power supply 90 to 240 VAC, single instrument with calibration standard kit (0.02 - 10.0 - 1000 NTU), 3 empty vials, Pharmcopeia compliant, optional 1-5 point calibration, quick cal, USB and RS232 Interface, LSData PC software for GLP-compliant Data management. |
3388 |
600130 |
Xylem WTW |
Turb 750 T Laboratory turbidimeter with tungsten lamp according to US EPA 180.1, universal power supply 90 to 240 VAC, single instrument with calibration standard kit (0.02 - 10.0 - 1000 NTU), 3 empty vials, Pharmacopeia compliant, optional 1-5 point calibration, Quick Cal, USB and RS232 Interface, LSData PC software for GLP-compliant Data management. |
3442 |
600311 |
Xylem WTW |
Turb 355 IR Portable Turbidimeter with LED according to DIN EN ISO 7027-1, battery operation: Single instrument in case with 4 MICRO (AAA size) alkaline batteries Calibration set (0.02-10.0-1000 NTU), 2 empty cuvettes and cleaning tissues. |
2092 |
600312 |
Xylem WTW |
Turb 355 T Portable Turbidimeter with tungsten lamp according to US EPA 180.1 battery operation Single instrument in case with 4 MICRO (AAA size) alkaline batteries Calibration set (0.02-10.0-1000 NTU), 2 empty cuvettes and cleaning tissues. |
2212 |
600320 |
Xylem WTW |
Turb 430 IR Portable turbidimeter for nephelometric measurement (90°) acc. DIN EN ISO 7027-1, incl. calibration standard kit (0.02 - 10 - 1000 NTU/FNU), 5 empty cuvette, tissues, batt. (4 AA Mignon), suitable for drinking water. Optional: LabStation LS Flex/430 with software package LSdata Flex/430 for GLP-compliant data export and rech.batt. RB Flex/430 (order no. 251 301) or rechargeable batteries RB Flex/430 (order no. 251 300, PC software LSdata Flex/430 (stand alone 902762). |
2059 |
600321 |
Xylem WTW |
Turb 430 IR/SET Portable turbidimeter (90°, Infrared) acc. DIN EN ISO 7027-1 incl. calibration standard kit (0.02-10-1000 NTU/FNU) in field case with table insert and accessories: Kal.Kit, 5 empty cuvette (28 mm), cleaning tissues, screw driver, PC-software Lsdata, PC cable AK 540 B, instruction. Optional: LabStation LS Flex/430 with PC-software LSdata Flex/430 for GLP-compliant data export and rechargeable batteries RB Flex/430 (order no. 251 301) or rechargeable batteries RB Flex/430 (order no. 251 300), PC software LSdata Flex/430 (stand alone, order no. 902762). |
2516 |
600325 |
Xylem WTW |
Turb 430 T Portable turbidimeter (90°, tungsten) acc. US EPA 180.1 incl. calibration standard kit (0,02-10-1000 NTU) and accessories: 5 empty cuvette (28mm), cleaning tissues, batt. Optional: LabStation LS Flex/430 with software package LS Flex/430 for GLP-compliant data export (order no. 251301) or rechargeable batteries RB Flex/430 (order no. 251300), PC software LS Flex/430 (standalone order no. 902762) |
2227 |
600326 |
Xylem WTW |
Turb 430 T / Set Portable turbidimeter (90°, tungsten) acc. US EPA 180.1 incl. calibration standard kit (0.02-10-1000 NTU) in field case with table insert and accessories: Kal.Kit, 5 empty cuvette (28 mm), cleaning tissues, screw driver, PC-software Lsdata, PC cable AK 540 B, instructions. Optional: LabStation LS Flex/430 with PC-software LSdata Flex/430 for GLP-compliant data export and rechargeable batteries RB Flex/430(order no. 251 301) or rech.batt. RB Flex/430 (order no. 251 300), PC software LSdata Flex/430 (stand alone, order no. 902762). |
2694 |
600542 |
Xylem WTW |
Kal.Kit P Turb 550/550IR Calibration kit for turbidimeter Turb 550 and 550 IR: 0.02 - 10.0 - 1000 NTU, cleaning tissues and indexing rings. |
322 |
600543 |
Xylem WTW |
Kal.Kit P Turb 555 IR Calibration kit for turbidimeter Turb 555 IR: 0.02 - 10.0 - 100 - 1750 NTU, cleaning tissues and indexing rings. |
443 |
600544 |
Xylem WTW |
Kal.Std P 10000 NTU IR Turbidity standard 10000 NTU for Turb 555 IR. |
450 |
600545 |
Xylem WTW |
Kal.Kit P Turb 555 Calibration kit for turbidimeter Turb 555, 0.02 - 10.0 - 100 - 1750 NTU, cleaning tissues and indexing rings. |
443 |
600546 |
Xylem WTW |
Kal.Std P 10000 NTU WL Turbidity standard 10000 NTU Turb 555 |
450 |
600547 |
Xylem WTW |
Kal.Kit P Turb 355 IR/T Calibration Set for Turbidimeter Turb 355 T, 335 IR: 0.02-10.0-1000 NTU, cleaning tissues and indexing rings. |
321 |
600560 |
Xylem WTW |
Kal.Kit Turb 430/750 IR Calibration standard kit for Turb® 430 IR /750 IR and photoFlex® Turb: 0.02-10-1000 NTU. |
320 |
600561 |
Xylem WTW |
Kal.Kit Turb 430/750 T Calibration standard kit for Turb® 430 T / Turb 750 T: 0.02-10-1000 NTU. |
345 |
600601 |
Xylem WTW |
Cell Turb/SET Empty cuvettes for laboratory turbidimeter Turb 550, Turb 550 IR, Turb 555 and Turb 555 (IR). Delivery: 3 pcs. |
181 |
600606 |
Xylem WTW |
Cell Turb 350 / 355 Set Empty cuvettes for portable turbidimeter Turb 350 / 355 IR and 355 T, Delivery: 3 pcs. |
181 |
600700 |
Xylem WTW |
VisoTurb® 900-P IDS IR turbidity sensor, titanium shaft, 0 bis 4000 FNU, pressure resistant up to 10 bars, with waterproof plug head for connection with cable AS/IDS-x. |
1679 |
600702 |
Xylem WTW |
Cal-Kit VT900 Calibration kit for VisoTurb® 900-P including each 250 ml turbidity standard 124 FNU and 1010 FNU and empty bottle for zero point calibration, (please see manual). |
305 |
600704 |
Xylem WTW |
SB VT900 Sample bottle for IDS turbidity sensor, volume 500 ml. |
44.8 |
902758 |
Xylem WTW |
AK Labor Interface cable with 9-pin socket for connecting an instrument to a PC via the RS 232 Interface. |
150 |
902762 |
Xylem WTW |
LSdata Flex/430 GLP compliant PC software for data management and -transfer for photoFlex® and Turb 430 series (stand alone). |
368 |
902763 |
Xylem WTW |
photoLab color+data spec photoLab® color PC-software package; CIE based color measurement (LAB, Luv…), Hazen (Pt-Co), Yellowness, Gardner etc. for photoLab® 7000 series together with GLP-compliant data management and export into LIMS. |
368 |
902780 |
Xylem WTW |
SM Pro Shock absorbing rubber elastic protective armoring for ProfiLine and MultiLine® portable meters. |
86 |
902842 |
Xylem WTW |
AK 540/B Interface cable for connection of instrument with 6-pin socket to a PC via RS 232 interface. |
154 |
902843 |
Xylem WTW |
AK 540/S Interface cable to connect the Turb® 430/750/pHotoFlex Series to printer P 3002 via the RS 232 interface. |
154 |
902867 |
Xylem WTW |
NT Multirange Universal power supply 100 to 240 V, 50/60 Hz for inoLab®, 340i, 350i, 197i, 1970i, MultiLine® 34x0, 36x0. |
150 |
902872 |
Xylem WTW |
NT USB Universal Universal USB power supply for ProfiLIne 33x0 portable meters and WLM Charger. |
33.3 |
902881 |
Xylem WTW |
ADA USB Adapter USB to serial interface RS 232 (9-pin socket) for WTW laboratory instruments without connection cable, instrument specific cable necessary. |
106 |
903830 |
Xylem WTW |
A 325/K Plastic armoring with protective hood for oxygen sensor CellOx® 325... and conductivity cell TetraCon® 325... |
275 |
903836 |
Xylem WTW |
A 925/K Armor for IDS field sensors including guard, suitable for TetraCon® 925, SensoLyt® 900, FDO® 925, material: POM. |
275 |
903838 |
Xylem WTW |
A 925-P Armor for IDS field sensors without guard designed for TetraCon® 925-P, SensoLyt® 900-P, SensoLyt® ORP 900-P, FDO® 925-P. material: POM |
178 |
903839 |
Xylem WTW |
A 925-P/K Armor for IDS field sensors including guard designed for TetraCon® 925-P, SensoLyt® 900-P, SensoLyt® ORP 900-P, FDO® 925-P, VisoTurb® 900-P, material: POM. |
268 |
903840 |
Xylem WTW |
A 925-P/S Armor for IDS field sensors including guard designed for TetraCon® 925-P, SensoLyt® 900-P,SensoLyt® ORP 900-P, FDO® 925-P. Guard: Stainless steel. |
452 |
903841 |
Xylem WTW |
A pHLab/K Plastic armoring for protecting pH and ORP electrodes with length 120 mm in the field and in a plant. |
118 |
903842 |
Xylem WTW |
D 3Sen Flow-through vessel for up to three pH, ORP, D.O. or conductivity sensors (also IDS). With tube adapter for commercially availabe garden hoses inner diameter 19 mm (3/4"). Including clamp also for mast mounting. |
655 |
903843 |
Xylem WTW |
pH/ MCS Puncture knife, made of stainless steel, for pH measurement of meat, cheese, fruits with a pH electrode model SenTix® Sp or SenTix® Sp-T 900, robust blade with adapted cut-out. |
588 |
903850 |
Xylem WTW |
AS/IDS-1.5 Connection cable for MPP IDS respectively IDS sensors with waterproof plug head. Length 1.5 m. |
95 |
903851 |
Xylem WTW |
AS/IDS-3 Connection cable for MPP IDS respectively IDS sensors with waterproof plug head. Length 3 m. |
128 |
903852 |
Xylem WTW |
AS/IDS-6 Connection cable for MPP IDS respectively IDS sensors with waterproof plug head. Length 6 m. |
142 |
903853 |
Xylem WTW |
AS/IDS-10 Connection cable for MPP IDS respectively IDS sensors with waterproof plug head. Length 10 m. |
162 |
903854 |
Xylem WTW |
AS/IDS-15 Connection cable for MPP IDS respectively IDS sensors with waterproof plug head. Length 15 m. |
186 |
903855 |
Xylem WTW |
AS/IDS-20 Connection cable for MPP IDS respectively IDS sensors with waterproof plug head. Length 20 m. |
203 |
903856 |
Xylem WTW |
AS/IDS-25 Connection cable for MPP IDS respectively IDS sensors with waterproof plug head. Length 25 m. Stored on reel (included) |
495 |
903857 |
Xylem WTW |
AS/IDS-40 Connection cable for MPP IDS respectively IDS sensors with waterproof plug head. Length 40 m. Stored on reel (included) |
583 |
903858 |
Xylem WTW |
AS/IDS-60 Connection cable for MPP IDS respectively IDS sensors with waterproof plug head. Length 60 m. Stored on reel (included) |
701 |
903859 |
Xylem WTW |
AS/IDS-100 Connection cable for MPP IDS respectively IDS sensors with waterproof plug head. Length 100 m. Stored on reel (included) |
911 |
903860 |
Xylem WTW |
KT MPP/SK Cable reel with sliding contacts for AS/IDS-x, without cable, with connectors. |
909 |
908370 |
Xylem WTW |
BPI/IDS Coded protection cap for IDS sensor input |
77 |
908371 |
Xylem WTW |
BPO/IDS Replacement protection cap for sonde output |
77 |
000428 |
Xylem WTW |
V/Schlauch/25 S Extension hose with quick coupling for PB 25, cable 2 m (6.5 ft), I.D. 8 mm |
38.8 |
000434 |
Xylem WTW |
Schlauch/25 S Suction tube with suction piece for PB 25, lenght 2 m (6.5 ft), 8 mm ID |
109 |
000443 |
Xylem WTW |
EF/1/25 12 x 1.0 l PE sample bottles for PB 25 |
136 |
000444 |
Xylem WTW |
EF/0,5/25 12 x 0.5 l glass sample bottles for PB 25 (require the use of insert EW/25/0.5) |
144 |
000449 |
Xylem WTW |
EW/25/0,5 Insert for 12 x 0.5 l glass sample bottles for PB 25 |
133 |
000670 |
Xylem WTW |
PF105 Sample bypass unit for direct supply of WTW analyzer with sample, completely mounted; not included: pumps |
1035 |
102282 |
Xylem WTW |
TFK 325-3 Temperature sensor for automatic temperature compensation in aqueous solutions including 3 m / 9.7 ft cable and waterproof plug (IP 67) |
189 |
102287 |
Xylem WTW |
TFK 325-EST-3,0 Temperature sensor (NTC), with R ½ inch-NPT- screw thread and weld-in socket (1.4571) for in-line mounting including 3 m cable and waterproof plug (IP 67) |
482 |
105412 |
Xylem WTW |
SensoLyt® Pt ORP combination electrode for heavily polluted wastewater, for use in flow-thru vessels: D 700/N, D 530, D 300/pH etc. With watertight S7 plug head (IP67); measuring range: -2000 … + 2000 mV |
374 |
107040 |
Xylem WTW |
VARiON®Plus 700 IQ Robust digital sensor for the ion-selective measurement (in-situ) of ammonium and nitrate, for use with the IQ SENSOR NET system. Supplied with: Sensor VARiON®Plus 700 IQ with 4 blind plugs and protective head. Please order electrodes separately. |
5330 |
107042 |
Xylem WTW |
VARiON®Plus Ref Reference electrode for mounting into sensors VARiON®Plus 700 IQ, NitraLyt® Plus, AmmoLyt® Plus |
606 |
107044 |
Xylem WTW |
VARiON®Plus NH4 Ammonium electrode for VARiON®Plus 700 IQ and AmmoLyt® Plus/AmmoLyt®, measuring range: 0.1 - 2.000 mg/l NH4-N |
441 |
107045 |
Xylem WTW |
VARiON®Plus NO3 Nitrate electrode for VARiON®Plus 700 IQ and NitraLyt®Plus/ NitraLyt®, Measuring range: 0.1 - 1000 mg/l NO3-N |
441 |
107046 |
Xylem WTW |
VARiON®Plus K Potassium electrode for VARiON®Plus 700 IQ and for AmmoLyt®Plus, measuring range: 1 - 1000 mg/l K+ |
441 |
107047 |
Xylem WTW |
VARiON®Plus Cl Chloride electrode for VARiON®Plus 700 IQ and for NitraLyt® Plus, measuring range: 1-1000 mg/l Cl- |
441 |
107050 |
Xylem WTW |
VARiON®/ES-1 Multiple standard solution 1 (low concentration) for VARiON®Plus 700 IQ/ AmmoLyt®Plus 700 IQ/NitraLyt®Plus 700 IQ; Volume: 1000 ml |
63 |
107052 |
Xylem WTW |
VARiON®/ES-2 Multiple standard solution 2 (high concentration) for VARiON®Plus 700 IQ/ AmmoLyt®Plus 700 IQ/NitraLyt®Plus 700 IQ; Volume: 1000 ml |
63 |
107056 |
Xylem WTW |
VARiON®700 IQ-SK Protection device for ISE electrodes, mountable on VARiON®Plus 700 IQ/ AmmoLyt®Plus 700 IQ/NitraLyt®Plus 700 IQ |
141 |
107057 |
Xylem WTW |
VARiON®/Epack Spare part set for VARiON®Plus 700 IQ. Consisting of 1 special box spanner for mounting and dismounting of electrodes, 1 blind plug, 3 spare O-ring seals for electrodes and 1 vessel for wet storage of electrodes. |
100 |
107060 |
Xylem WTW |
VARiON®Plus A comp SET NH4 Robust digital sensor for ion-selective measurement of ammonium and nitrate (in-situ) for use with the IQ SENSOR NET system. Supplied with: Sensor VARiON®Plus 700 IQ, reference electrode VARiON® Ref, ammonium electrode VARiON®Plus NH4 and compensation electrodeVARiON®Plus K (potassium). Please order SACIQ cable separately. |
6649 |
107062 |
Xylem WTW |
VARiON®Plus N comp SET NO3 Robust digital Sensor for ion-selective measurement of ammonium and nitrate (in-situ) for use with the IQ SENSOR NET system. Supplied with: Sensor VARiON®Plus 700 IQ, reference electrode VARiON® Ref, nitrate electrode VARiON®Plus NO3 and compensation electrode VARiON®Plus Cl (chloride). Please order SACIQ cable separately. |
6649 |
107066 |
Xylem WTW |
VARiON®Plus AN/A comp SET NH4 & NO3 Robust digital sensor for ion-selective measurement of ammonium and nitrate (in-situ) for use with the IQ SENSOR NET system. Supplied with: Sensor VARiON®Plus 700 IQ, reference electrode VARiON® Ref, measuring electrodes VARiON®Plus NH4 and VARiON®Plus NO3, compensation electrode VARiON®Plus K (potassium). Please order SACIQ cable separately. |
7123 |
107068 |
Xylem WTW |
VARiON®Plus AN/N comp SET NH4 & NO3 Robust digital sensor for ion-selective measurement of ammonium and nitrate (in-situ) for use with the IQ SENSOR NET system. Supplied with: Sensor VARiON®Plus 700 IQ, reference electrode VARiON® Ref, measuring electrodes VARiON®Plus NH4 and VARiON®Plus NO3, compensation electrode VARiON®Plus Cl (chloride). Please order SACIQ cable separately. |
7123 |
107070 |
Xylem WTW |
AmmoLyt® Plus 700 IQ Robust digital ammonium sensor for ion-selective electrodes (in-situ measuring), for use with the IQ SENSOR NET system. With built-in lightning protection, pre-amplifier and temperature sensor. Not included: Electrodes VARiON® Ref, VARiON®Plus NH4, VARiON®Plus K and SACIQ connection cable (Please order separately). |
4241 |
107072 |
Xylem WTW |
AmmoLyt® Plus SET/Comp Robust digital ammonium sensor for ion-selective electrodes (in-situ measuring), for use with the IQ SENSOR NET system, delivered with VARiON® Ref, VARiON®Plus NH4 and VARiON®Plus K electrodes. With built-in lightning protection, pre-amplifier and temperature sensor. Not included: SACIQ connection cable (Please order separately). |
5608 |
107080 |
Xylem WTW |
NitraLyt®Plus 700 IQ Robust digital nitrate sensor for ion-selective electrodes (in-situ measuring), for use with the IQ SENSOR NET system. With built-in lightning protection, pre-amplifier and temperature sensor. Not included: Electrodes VARiON® Ref, VARiON®Plus NO3, VARiON®Plus Cl and SACIQ connection cable (Please order separately). |
4367 |
107082 |
Xylem WTW |
NitraLyt®Plus SET/Comp Robust digital nitrate sensor for ion-selective electrodes (in-situ measuring), for use with the IQ SENSOR NET system, delivered with VARiON® Ref, VARiON®Plus NO3 and VARiON®Plus Cl electrodes. With built-in lightning protection, pre-amplifier and temperature sensor. Not included: SACIQ connection cable (Please order separately). |
5729 |
108073 |
Xylem WTW |
D 300/pH Flow-thru vessel for pH/ORP and temperature measuring |
952 |
108455 |
Xylem WTW |
VP 6-19/10 VP 6-pole electrode socket, 10 m cable KA 19 (1 coaxial + 3 cords), up to 266 °F (130 °C), free end |
471 |
108461 |
Xylem WTW |
K 5 S Coaxial electrode plug, 5 m coaxial cable, S plug (extension cable) |
126 |
108507 |
Xylem WTW |
AS 9-HI-6,0 Connecting cable with exposed cable ends for direct connection (high impedance) of pH electrodes to analogue monitors.Cable length 6 m (19 ft) |
232 |
108532 |
Xylem WTW |
MZ WIS 40 IC 44 Weld-in socket fitting (chamfered), stainless steel (1.4404), for installation of CHEMtrac 830 M into pipes; adaption DN25. |
213 |
108533 |
Xylem WTW |
MZ WIS 40 ST 44 Weld-in socket fitting (straight), stainless steel (1.4404), for installation of CHEMtrac 830 M into pipes; adaption DN25. |
207 |
108540 |
Xylem WTW |
S 200 Float with pendulum mounting assembly for on-line sensors with 40 mm (1.57 in) shaft diameter with UA 55 extension assembly or for spectral sensors with supplement kit VIS Set/EH for horizontal mounting. |
854 |
108542 |
Xylem WTW |
S 200/2 Float with pendulum mounting assembly for 2 on-line sensors with 40 mm (1.57 in) shaft diameter with UA 55 extension assembly. |
1766 |
108592 |
Xylem WTW |
ADA/AMPH Adapter for direct connection of D.O./pH sensors of series TriOxmatic® and SensoLyt® 700/690 to analogue monitors of Oxi/pH 29X series |
122 |
109100 |
Xylem WTW |
SensoLyt® SE pH combination electrode esp. suited for measurements in heavily polluted wastewater, for use in flow-thru vessel: D 700/N, D 530, D 300/pH etc. With watertight S7 plug head (IP 67); measuring range 0 … 12 pH |
330 |
109102 |
Xylem WTW |
SensoLyt® EC pH combination electrode especially suited for normally polluted wastewater (e.g. municipal wastewater). With watertight S7 plug head (IP 67); measuring range 0 … 12 pH |
224 |
109103 |
Xylem WTW |
SensoLyt® DW pH combination electrode especially for drinking water applications. With watertight S7 plug head (IP 67); measuring range 0 … 14 pH |
280 |
109114 |
Xylem WTW |
SensoLyt® TFA pH combination electrode especially suited for industrial or not typical municipal wastewater, with armouring for use in SensoLyt® sensors. With watertight S7 plug head (IP 67); measuring range 2 … 12 pH |
296 |
109115 |
Xylem WTW |
SensoLyt® SEA pH combination electrode especially suited for measurements in heavily polluted wastewater, with armouring for use in SensoLyt® sensors. With watertight S7 plug head (IP 67); measuring range 0 … 12 pH |
305 |
109115EX |
Xylem WTW |
SensoLyt® SEA EX pH electrode for hazardous areas (only with SensoLyt® 650-7 Sensor), measuring range 2 …12 pH, for heavily polluted wastewater. |
409 |
109117 |
Xylem WTW |
SensoLyt® ECA pH combination electrode esp. suited for normally polluted wastewater (e.g. municipal wastewater) with armouring for use in SensoLyt® sensors. With watertight S7 plug head (IP 67); measuring range 0 … 12 pH |
232 |
109117EX |
Xylem WTW |
SensoLyt® ECA EX pH electrode for hazardous areas (only with SensoLyt® 650-7 sensor), measuring range 2 …12 pH, for normally polluted wastewater (e.g. municipal wastewater). |
276 |
109118 |
Xylem WTW |
SensoLyt® SEA-HP pH combination electrode with optimized armouring for use under high pressure/temperature conditions, for installation in SensoLyt® sensors. With watertight S7 plug head (IP 67); measuring range 4 … 12 pH |
431 |
109118EX |
Xylem WTW |
SensoLyt® SEA-HP EX pH electrode for hazardous areas (only with SensoLyt® 650-7 sensor), measuring range 4 …12 pH, for use under high pressure/temperature conditions. |
520 |
109119 |
Xylem WTW |
SensoLyt® DWA pH combination electrode especially for drinking water applications, for installation in sensors of SensoLyt® 650/690/700 (IQ) series. With watertight S7 plug head (IP 67); measuring range 0 … 14 pH |
301 |
109119EX |
Xylem WTW |
SensoLyt® DWA EX pH electrode for hazardous areas (only with SensoLyt® 650-7 sensor), measuring range 0 …14 pH, for drinking water applications. |
361 |
109125 |
Xylem WTW |
SensoLyt® PtA ORP combination electrode especially suited for measurements in heavily polluted wastewater, for installation in SensoLyt® sensors. With watertight S7 plug head (IP 67); measuring range - 2000 … + 2000 mV |
400 |
109125EX |
Xylem WTW |
SensoLyt® PtA EX ORP electrode for hazardous areas (only with SensoLyt® 650-7 sensor), measuring range ±2000 mV, for heavily polluted wastewater. |
480 |
109126 |
Xylem WTW |
SensoLyt PtFA ORP combination electrode especially suited for industrial or not typical municipal wastewater, for installation in SensoLyt® sensors. With watertight S7 plug head (IP 67); measuring range - 2000 … + 2000 mV |
422 |
109170 |
Xylem WTW |
SensoLyt® 700 IQ Robust digital pH/ORP sensor for pH/ORP electrodes SensoLyt® SEA/DWA/ECA/PtA for use with the IQ SENSOR NET. With built-in pre-amplifier and temperature sensor (NTC), with SensCheck function, without connection cable (please order SACIQ separately) |
1178 |
109171 |
Xylem WTW |
SensoLyt® 700 IQ SW Robust digital pH/ORP sensor for SensoLyt® SEA/ DWA/ECA/PtA pH/ORP electrodes, in sea water design, for use with the IQ SENSOR NET. With built-in pre-amplifier and temperature sensor (NTC), with SensCheck function, without connection cable (please order SACIQ separately) |
1355 |
109173 |
Xylem WTW |
SensoLyt® 700 IQ/SET Robust digital pH/ORP sensor (SensoLyt® 700 IQ) including pH electrode (SensoLyt® SEA) and 7 m (23 ft) sensor adapter cable (SACIQ-7,0) |
1274 |
109174 |
Xylem WTW |
SensoLyt® 700 IQ/SET1 Robust digital pH/ORP sensor (SensoLyt® 700 IQ) including ORP electrode (SensoLyt® PtA) and 7 m (23 ft) sensor adapter cable (SACIQ-7,0) |
1321 |
109180 |
Xylem WTW |
SensoLyt® 690-7 Standard pH/ORP sensor with low impedance signal transmission, for connection to analogue monitors. With built-in pre-amplifier and temperature sensor (NTC), with 7 m (23 ft) cable and watertight plug |
895 |
109191 |
Xylem WTW |
SensoLyt® 700-7 Standard pH/ORP armature with low impedance signal transmission, with SensCheck function, for connection to EcoLine and QuadroLine® monitors. With built-in pre-amplifier and temperature sensor (NTC), with 7 m (23 ft) cable and watertight plug |
1242 |
109194 |
Xylem WTW |
SensoLyt® 700-SK Protecting cage (protection against strikes/ solids) for SensoLyt® pH/ORP electrodes within SensoLyt® sensors |
139 |
109195 |
Xylem WTW |
SensoLyt® 650-7 pH sensor (passive) with high impedance signal transmission, for connection to analogue monitors. With built-in temperature sensor (NTC), with cable of 7 m (23 ft) and open cable ends |
703 |
109195EX |
Xylem WTW |
SensoLyt® 650-7 EX Analog pH/Redox sensor for hazardous areas (Ex ib IIC T6 Gb X) with high impedance signal transmission, for the use with StratosProA201XpH-0(-1). With integrated temperature sensor (NTC) and 7m cable with open cable ends. Adequate pH electrodes have to ordered separately. |
900 |
109232 |
Xylem WTW |
GWA Weight ring for S 200 float |
228 |
109233 |
Xylem WTW |
PL 80-120pH Low-maintenance pH combination electrode, glass shaft, SILAMID® reference, 2 hole diaphragm, DuraLid reference system, sphere membrane, H glass, S8 plug head, length 120 mm (4.72 in), 12 mm (0.47 in) Ø, 0…14 pH, 32…266 °F (0…130 °C) |
308 |
109234 |
Xylem WTW |
PL 80-225pH Low-maintenance pH combination electrode, glass shaft, SILAMID® reference, 2 hole diaphragm, DuraLid reference system, sphere membrane, H glass, S8 plug head, length 225 mm (8.86 in), 12 mm (0.47 in) Ø, 0…14 pH, 32…266 °F (0…130 °C), for installation into CHEMtrac 830 M |
354 |
109237 |
Xylem WTW |
CHEMtrac 830 M Manual retractable housing, stainless steel (1.4404), for installation/changing/ maintenance of pH electrodes without process interruption (specific valve); adaption DN25. |
3191 |
109239 |
Xylem WTW |
PL 82-225pHT VP Low-maintenance pH combination electrode with Pt 100, glass shaft, SILAMID® reference, 2 hole diaphragm, DuraLid reference system, sphere membrane, H glass, VP screw plug head, length 225 mm (8.86 in), 12 mm (0.47 in) Ø, 0…14 pH, 32…266 °F (0…130 °C), for installation into CHEMtrac 830 M |
427 |
109260 |
Xylem WTW |
UA 55 Universal extension assembly (incl. handle and set of seals) for mounting of sensors of series 650/690/70X and 70X IQ, length without sensor: 317 mm (12.48 in) |
251 |
109261 |
Xylem WTW |
UA 130 Universal extension assembly (incl. handle and set of seals) for mounting of sensors of series 650/690/70X and 70X IQ, length without sensor: 1067 mm (42.01 in) |
280 |
109263V** |
Xylem WTW |
UA-SO Armatur Universal extension assembly (incl. handle and set of seals) for mounting of sensors of series 650/690/70X and 70X IQ, length without sensor: selectable between 240…2600 mm (9.45…102.36 in) |
418 |
109265 |
Xylem WTW |
UA/DS Spare set of O-ring seals for UA sensor extensions of all lengths |
66 |
109267EX |
Xylem WTW |
UA EX Universal extension assembly (incl. handle and set of seals) for mounting of EX-sensors SensoLyt® 690-7 EX or TetraCon® 700-… EX. Length without sensor: 175 mm (6.89 in) |
292 |
109270 |
Xylem WTW |
EH/P 170 SensoClean pendulum mounting assembly for installation of on-line sensors with 40 mm (1.57 in)shaft diameter and UA armatures. Supplied with adjustable boom (620 mm/24.4 in), pendulum mounting assembly (stainless steel 1.4301), movable counterweight for fine adjustment |
489 |
109270EX |
Xylem WTW |
EH/P 170 EX Pendulum mounting assembly for online sensors |
581 |
109271 |
Xylem WTW |
EH/R 170 Sensor holder for mounting of on-line sensors with 40 mm (1.57 in) shaft diameter, in a fixed distance to a rail. Supplied with pendulum head (POM) and 1580 mm (62.2 in) long outrigger pipe (stainless steel 1.4301). Without clamp set fixture (Please order BE/R 170 separately |
775 |
109272 |
Xylem WTW |
EH/F 170-1,5 SensoClean swing mounting assembly for installation of on-line sensors with 40 mm shaft diameter and UA armatures. Supplied with plastic chain (4 m/13 ft) for use in wastewater and 1.5 m/4.9 ft boom (stainless steel 1.4301) |
314 |
109272EX |
Xylem WTW |
EH/F 170-1,5 EX Swing mounting assembly for online sensors, boom length 1.5m, incl. Chain |
443 |
109273 |
Xylem WTW |
EH/F 170-2,5 SensoClean swing mounting assembly for installation of on-line sensors with 40 mm shaft diameter and UA armatures. Supplied with plastic chain (5 m/16 ft) for use in wastewater and 2.5 m/8.1 ft boom (stainless steel 1.4301) |
360 |
109273EX |
Xylem WTW |
EH/F 170-2,5 EX Swing mounting assembly for online sensors, boom length 2.5m, incl. Chain |
508 |
109274 |
Xylem WTW |
EH/W 170 Sensor fixture assembly for direct wall mounting of UA armatures and sensors of series 650/690/70X and 70X IQ |
540 |
109274EX |
Xylem WTW |
EH/W 170 EX Fixture assembly for direct wall mounting |
681 |
109275EX |
Xylem WTW |
BE/M 170-D EX Pivoting wall mounting for swing or pendulum holder |
318 |
109276 |
Xylem WTW |
BE/M 170 Masonary fixture installation of EH-F 170 swing or EH/P 170 pendulum mounting assembly directly on the basin edge or on top of a wall |
198 |
109278 |
Xylem WTW |
BE/R 170 Pipe fixture for installation of EH-F 170 swing or EH/P 170 pendulum mounting assembly directly to a pipe (e.g. basin railing) |
277 |
109278EX |
Xylem WTW |
BE/R 170 EX Pipe fixture |
392 |
109279 |
Xylem WTW |
BE/R 170-D Swivel/pivot clamp fixture for mounting of a swing or pendulum mounting assembly directly to a pipe (e.g. basin railing) |
339 |
109279EX |
Xylem WTW |
BE/R 170-D EX Swivel/pivot clamp fixture for rail mounting |
428 |
109280 |
Xylem WTW |
BE/ST 170 Robust Vario floor mounting stand for installation on a concrete base etc. Supplied with universal joint fixture to accommodate a swing or pendulum mounting assembly and 2 brackets for attaching a protective roof, incl. aluminium diecast base, wallplugs and screws |
633 |
109280EX |
Xylem WTW |
BE/ST 170 EX Floor mounting stand |
868 |
109281 |
Xylem WTW |
BE/ST 170-R Vario pipe mounting stand. Supplied with universal joint fixture to accommodate a swing or pendulum mounting assembly and 2 brackets for attaching a protective roof |
665 |
109281EX |
Xylem WTW |
BE/ST 170-R EX Pipe mounting stand |
840 |
109283 |
Xylem WTW |
BE/ST 170-M Vario wall mounting stand. Supplied with universal joint fixture to accommodate a swing or pendulum mounting assembly and 2 brackets for attaching a protective roof |
648 |
109283EX |
Xylem WTW |
BE/ST 170-M EX Wall mounting stand |
781 |
109284 |
Xylem WTW |
SD/K 170 Sun shield for outdoor installation of junction boxes (e.g. junction box Kl/pH 170) or an IQ SENSOR NET module |
96 |
109286 |
Xylem WTW |
MR/SD 170 Mounting kit for attaching sun shields to pipes |
133 |
109288 |
Xylem WTW |
MS/SD 170 Mounting kit for SSH/IQ sun shield to a mounting stand |
67 |
109289 |
Xylem WTW |
MS/RKH 170 Pipe bracket for installation of a second sensor to a EH/P 170 pendulum mounting assembly (2 pieces required) |
96 |
109289EX |
Xylem WTW |
MS/RKH 170 EX Pipe bracket for second sensor at EH/P 170 |
102 |
109290 |
Xylem WTW |
MS/KK 170 Double junction clamp for mounting of additional EH/F 170 swing or EH/P 170 pendulum mounting assembly to a Vario mounting stand BE/ST 170-X |
253 |
109290EX |
Xylem WTW |
MS/KK 170 EX Double junction clamp for EH/F 170 or EH/P 170 at BE/ST 170-x for second sensor |
290 |
109295 |
Xylem WTW |
SSH/IQ Sun shield for mounting of IQ SENSOR NET modules and series 171/170 monitors to mounting stands |
167 |
109304 |
Xylem WTW |
IN/SET1 Installation set for mounting of one on-line sensor. Supplied with: Single sensor holder EH/U 170; SensorClean swing mounting EH/F 170-1,5; Vario floor mounting stand BE/ST 170; Sun shield SSH/IQ |
934 |
109305 |
Xylem WTW |
IN/SET2 Installation set for mounting of up to two on-line sensors. Supplied with: Twin sensor holder EH2/U 170; SensorClean swing mounting EH/F 170-1,5; Vario floor mounting stand BE/ST 170; Sun shield SSH/IQ |
996 |
109306 |
Xylem WTW |
IN/SET3 Installation set for mounting of up to three on-line sensors. Supplied with: Tripple sensor holder EH3/U 170; SensorClean swing mounting EH/F 170-1,5; Vario floor mounting stand BE/ST 170; Sun shield SSH/IQ |
1132 |
109317 |
Xylem WTW |
EH/SW Single electrode holder in seawater design for direct mounting of series 650/690/70X and 70X IQ (SW) sensors |
57 |
109320 |
Xylem WTW |
EH/U 170 Sensor holder for direct mounting of series 650/690/70X and 70X IQ sensors to a swing mounting assembly |
121 |
109320EX |
Xylem WTW |
EH/U 170 EX Sensor holder for 1 sensor |
152 |
109323 |
Xylem WTW |
EH2/U 170 Twin sensor holder for WTW sensors of series 650, 690, 70X and 70X IQ |
213 |
109323EX |
Xylem WTW |
EH2/U 170 EX Sensor holder for 2 sensors |
269 |
109325 |
Xylem WTW |
EH3/U 170 Triple sensor holder for WTW sensors of series 650, 690, 70X and 70X IQ |
275 |
109351EX |
Xylem WTW |
ZU 0274 Pipe-mount kit for Stratos series |
98 |
109353EX |
Xylem WTW |
ZU0738 Panel-mount kit for Stratos series |
54 |
109355EX |
Xylem WTW |
ZU 0737 Protective hood for Stratos series |
111 |
109360 |
Xylem WTW |
EH/W 171 Pivot wall mount with 42 cm side arm for IQ sensors to pipes with 30 mm (1.18 in) diameter (EH/WT-D30, EH/WB please order separately) |
1230 |
109361 |
Xylem WTW |
EH/W 172 Fixed wall mount for IQ sensors to pipes with 30 mm (1.18 in) diameter (EH/WT-D30, EH/WB please order separately) |
339 |
109362 |
Xylem WTW |
EH/WB Sensor holder for sensor with 60 mm (2.36 in) diameter for attachment to pipes with 30 mm (1.18 in) diameter |
353 |
109363 |
Xylem WTW |
EH/WT-D30 Pipe D30 x 2600 mm. Adaptable to EH/W 171, EH/W 172, IFL-RM, IFL-D |
339 |
109365 |
Xylem WTW |
EH/W 173 Fixed wall mount with side arm for IQ sensors to pipes with 30 mm (1.18 in) diameter in combination with deflector armature IFL-E or sensor holder EH/WB (EH/WT-D30, IFL-E or EH/WB please order separately) |
552 |
109366 |
Xylem WTW |
EH/W RM Rail connection for wall mount EH/W 170 to EH/W 173 |
891 |
109367 |
Xylem WTW |
EH/WB-40 Sensor holder for sensor with 60 mm (2.36 in) diameter for attachment to pipes with 40 mm (1.57 in) diameter |
386 |
109444EX |
Xylem WTW |
Stratos Pro A 201 X pH 0 pH transmitter for hazardous areas (II 2(1)G Ex ib[ia] IIC T4) with 1 analog current output. |
2620 |
109445EX |
Xylem WTW |
Stratos Pro A 201 X pH 1 pH transmitter for hazardous areas (II 2(1)G Ex ib[ia] IIC T4) with 2 analog current outputs. |
3074 |
109446EX |
Xylem WTW |
WG 21 A7 Isolated amplifier to power the EX-transmitter StratosPro in an intrinsically safe way, power supply 90 … 253V, explosion protection II (1) G [Ex ia Ga] IIC. |
339 |
109447EX |
Xylem WTW |
WG 21 A7 Opt. 336 Isolated amplifier to power the EX-transmitter StratosPro in an intrinsically safe way, power supply 24VAC/DC, explosion protection II (1) G [Ex ia Ga] IIC. |
339 |
109448EX |
Xylem WTW |
WG 21 A7 Opt. 470 Isolated amplifier to power the EX-transmitter StratosPro in an intrinsically safe way, power supply 90 … 253V, HART® communication, explosion protection II (1) G [Ex ia Ga] IIC. |
398 |
109449EX |
Xylem WTW |
WG 21 A7 Opt. 336, 470 Isolated amplifier to power the EX-transmitter StratosPro in an intrinsically safe way, power supply 24VAC/DC, HART® communication, explosion protection II (1) G [Ex ia Ga] IIC. |
398 |
180102 |
Xylem WTW |
ZBK/NH500/TC Accessory kit for on-line ammoni sensor NH 500/TC for TresCon® and TresCon® Uno included: 3 membrane caps and 50 ml electrolyte |
327 |
191230 |
Xylem WTW |
pH 298 NTC Monitor for direct connection of analogue pH/ORP electrodes, with 2 analog and relay outputs, Modbus, 115V/230V and NTC |
1304 |
191232 |
Xylem WTW |
pH 298 Pt100 Monitor for direct connection of analogue pH/ORP electrodes, with 2 analog and relay outputs, Modbus, 115V/230V and Pt100 |
1304 |
191234 |
Xylem WTW |
pH 298 Pt1000 Monitor for direct connection of analogue pH/ORP electrodes, with 2 analog and relay outputs, Modbus, 115V/230V and Pt1000 |
1304 |
201640 |
Xylem WTW |
TriOxmatic® 700 IQ Universal digital D.O. sensor for monitoring/controlling O2 input in wastewater treatment plants for use with IQ SENSOR NET. Supplied with accessory kit (ZBK 600) comprising: 2 exchange membrane heads (WP 600/2), 50 ml electrolyte solution (ELY/A), 50 ml cleaning solution (RL-AG/Oxi), 1x cathode cleaner (SF 300), without connection cable (SACIQ order separately) |
1907 |
201641 |
Xylem WTW |
TriOxmatic® 700 IQ SW Universal digital D.O. sensor for monitoring/ controlling the O2 input, in sea water design, for use with IQ SENSOR NET. Supplied with accessory kit (ZBK 600) comprising: 2 exchange membrane heads (WP 600/2), 50 ml electrolyte solution (ELY/A), 50 ml cleaning solution (RL-AG/Oxi), 1 x cathode cleaner (SF 300), without connection cable (SACIQ order separately) |
2069 |
201644 |
Xylem WTW |
TriOxmatic® 701 IQ Fast response time digital D.O. sensor for use in wastewater treatment plants, e.g. denitrification, for use with IQ SENSOR NET. Supplied with accessory kit (ZBK 25i) comprising: 2 exchange membrane heads (WP?25i/2), 50 ml electrolyte solution (ELY/A), 50 ml cleaning solution (RL-AG/Oxi), 1x cathode cleaner (SF 300), without connection cable (SACIQ order separately) |
1994 |
201646 |
Xylem WTW |
TriOxmatic® 702 IQ Digital D.O. sensor for trace level measurements in the ppb range, e.g. ultrapure water/boiler feed water, for use with IQ SENSOR NET. Supplied with accessory kit (ZBK 25i) comprising: 2 exchange membrane heads (WP?25i/2), 50 ml electrolyte solution (ELY/A), 50 ml cleaning solution (RL-AG/Oxi), 1x cathode cleaner (SF 300), without connection cable (SACIQ order separately) |
3443 |
201650 |
Xylem WTW |
FDO 700 IQ Digital calibration free optical D.O. sensor (universal use). Optimized for monitoring/controlling the O2 input in wastewater treatment plants, for use with IQ SENSOR NET. Factory calibrated system composed of sensor FDO® 700 IQ and membrane cap SC-FDO® 700, without connection cable (SACIQ order separately) |
2124 |
201652 |
Xylem WTW |
FDO® 700 IQ SW Digital calibration free optical D.O. sensor (universal use). Optimized for measuring and controlling the O2 input in seawater applications, for use with IQ SENSOR NET. Factory calibrated system composed of sensor FDO® 700 IQ SW, membrane cap SC-FDO® 700 and protective cap MSK FDO®, without connection cable (SACIQ order separately). |
2415 |
201653 |
Xylem WTW |
FDO 701 IQ SW Digital calibration free optical D.O. sensor with fast response time (universal use). Optimized for measuring/controlling the O2 input in seawater applications, for use with IQ SENSOR NET. Factory calibrated system composed of sensor FDO® 700 IQ SW, membrane cap SC-FDO® 701and protective cap MSK FDO®, without connection cable (SACIQ order separately) |
2415 |
201654 |
Xylem WTW |
SC-FDO® 700 Universal sensor cap for FDO® 700 IQ/700 IQ SW |
197 |
201655 |
Xylem WTW |
SC-FDO® 701 Fast response time sensor cap for FDO® IQ 701/IQ 701 SW |
197 |
201660 |
Xylem WTW |
FDO 701 IQ Digital calibration free optical D.O. sensor with fast response time (universal use). Optimized for monitoring/controlling the O2 input in waste water treatment plants, for use with IQ SENSOR NET. Factory calibrated system composed of sensor FDO® 700 IQ and membrane cap SC-FDO® 701, without connection cable (SACIQ order separately). |
2124 |
201670 |
Xylem WTW |
TriOxmatic® 700-7 Universal D.O. sensor with SensCheck for monitoring/controlling O2 input in wastewater treatment plants, for use with Eco-, Quadro- and TecnoLine monitor. Supplied with accessory kit (ZBK 600) comprising: 2 exch. membr. heads (WP 600/2), 50 ml electrolyte solution (ELY/A), 50 ml cleaning solution, 1x cathode cleaner (SF300), with integr. temperature sensor (NTC), 7 m/23 ft cable and watertight plug |
1840 |
201672 |
Xylem WTW |
TriOxmatic® 700-15 Universal D.O. sensor with SensCheck for monitoring/controlling O2 input in wastewater treatment plants, for use with Eco-, Quadro- and TecnoLine monitor. Supplied with accessory kit (ZBK 600) comprising: 2 exch. membr. heads (WP 600/2), 50 ml electrolyte solution (ELY/A), 50 ml cleaning solution, 1x cathode cleaner (SF300), with integr. temperature sensor (NTC), 15 m/49 ft cable and watertight plug |
1882 |
201678 |
Xylem WTW |
TriOxmatic® 701-7 D.O. sensor with SensCheck, enhanced accuracy at low level D.O. concentrations (e.g. denitrification), for use with analogue monitor. Supplied with accessory kit (ZBK 25i) comprising: 2 exch. Membr. Heads (WP 25i/2), 50 ml electrolyte solution (ELY/A), 50 ml cleaning solution, 1x cathode cleaner (SF300), with integr. Temperature sensor (NTC), 7 m/23 ft cable and watertight plug |
1907 |
201680 |
Xylem WTW |
TriOxmatic® 701-15 D.O. sensor with SensCheck, enhanced accuracy at low level D.O. concentrations (e.g. denitrification), for use with analogue monitor. Supplied with accessory kit (ZBK 25i) comprising: 2 exch. Membr. Heads (WP 25i/2), 50 ml electrolyte solution (ELY/A), 50 ml cleaning solution, 1x cathode cleaner (SF300), with integr. Temperature sensor (NTC), 15 m/49 ft cable and watertight plug |
2063 |
201682V* |
Xylem WTW |
TriOxmatic® 701-SO D.O. sensor with SensCheck, enhanced accuracy at low level D.O. concentrations (e.g. denitrification), for use with analogue monitor. Supplied with accessory kit (ZBK 25i) comprising: 2 exch. Membr. Heads (WP 25i/2), 50 ml electrolyte solution (ELY/A), 50 ml cleaning solution, 1x cathode cleaner (SF300), with integr. Temperature sensor (NTC), customized cable length and watertight plug |
1960 |
201690 |
Xylem WTW |
TriOxmatic® 690-7 Universal D.O. sensor for monitoring/controlling O2 input in wastewater treatment plants, for use with analogue monitor. Supplied with accessory kit (ZBK 600) comprising: 2 exch. Membr. Heads (WP 600/2), 50 ml electrolyte solution (ELY/A), 50 ml cleaning solution, 1x cathode cleaner (SF 300), with integrated temp. Sensor (NTC), 7 m/23 ft cable and watertight plug |
1328 |
201692 |
Xylem WTW |
TriOxmatic® 690-15 Universal D.O. sensor for monitoring/controlling O2 input in wastewater treatment plants, for use with analogue monitor. Supplied with accessory kit (ZBK 600) comprising: 2 exch. Membr. Heads (WP 600/2), 50 ml electrolyte solution (ELY/A), 50 ml cleaning solution, 1x cathode cleaner (SF 300), with integrated temp. Sensor (NTC), 15 m/49 ft cable and watertight plug |
1364 |
201693V* |
Xylem WTW |
TriOxmatic® 690-SO* Universal D.O. sensor for monitoring/controlling O2 input in wastewater treatment plants, for use with analogue monitor. Supplied with accessory kit (ZBK 600) comprising: 2 exch. Membr. Heads (WP 600/2), 50 ml electrolyte solution (ELY/A), 50 ml cleaning solution, 1x cathode cleaner (SF 300), with integrated temp. Sensor, customized cable length and watertight plug |
1374 |
202620 |
Xylem WTW |
ZBK 600 Accessory kit for D.O. sensors TriOxmatic® 600/690/700/700 IQ/700 IN series, complete set for regeneration of D.O. electrode. Included: 2 exchange membrane heads (WP 600/2), 50 ml electrolyte solution (ELY/A), 50?ml cleaning solution (RL-AG/Oxi), 1x cathode cleaner (SF 300) |
267 |
202621 |
Xylem WTW |
ZBK 25i Accessory kit for D.O. sensors TriOxmatic® 601/701(IQ)/702 (IQ) series, complete set for regeneration of D.O. electrode Included: 2 exchange membrane heads (WP 25i/2), 50 ml electrolyte solution (ELY/A), 50?ml cleaning solution (RL-AG/Oxi), 1x cathode cleaner (SF 300) |
267 |
202850 |
Xylem WTW |
WP 600/2 Exchange membrane heads (2 pcs) for D.O. sensor TriOxmatic® 600/690/ 700 (IQ/IN) series |
123 |
202852 |
Xylem WTW |
WP 25i/2 Exchange membrane heads (2 pcs) for D.O. sensor TriOxmatic® 601/701 (IQ)/702 (IQ) series |
123 |
203745 |
Xylem WTW |
D 700/N Flow-thru vessel for multiparameter measurements, for use with: TriOxmatic® 690/700(IQ)/701(IQ), SensoLyt® SE/DW/EC/Pt, TetraCon® 325 and TFK 325. Please order suitable sensor flange separately |
1385 |
203747 |
Xylem WTW |
D 702/N Flow-thru cell for continuous oxygen measurement, primarily for measurements in the ppb range with TriOxmatic® 702 (IQ). Also useable for TriOxmatic® 690/700/700 IN/701 (IQ). Please order suitable sensor flange separately |
1004 |
203749 |
Xylem WTW |
DMS/N Universal flow-thru vessel for multiparameter measurements with up to four sensors, e.g. for use in the discharge of a waste water treatment plant. Please order suitable sensor flange separately. Closures or connections must be made on site. |
2115 |
203751 |
Xylem WTW |
EBS 700-DU/N Mounting set for measurements in pipelines, for all sensors of the 650/690/ 700(IQ)/701(IQ) series. Consisting of a bonded sleeve for standard 45° PVC T-piece (d 63 DN 50), O-ring seals and union nut. Please order suitable sensor adapter (ADA-XX) separately |
271 |
203753 |
Xylem WTW |
EBST 700-DU/N Flow-through adapter for measurements in pipelines, for all sensors of the 650/ 690/700(IQ)/701(IQ) series. Consisting of a 45° PVC T-piece (d 63 DN 50) with bonded sleeve. O-ring seals and union nut. Please order suitable sensor fadapter (ADA-XX) separately. |
352 |
203754 |
Xylem WTW |
EBST 700-DU/ND Flow-thru adapter for measurements in pipelines with air pressure cleaning connection for use with sensors 70X, 70X IQ (pre-pressure max. 0.5 m water column) consisting of a PVC 45° T piece (d?63 DN 50) with bonded sleeve, O-ring seals and union nut, 2 x 180° shifted pressure cleaning injector with centric air-pressure connector 4/6 mm (max 6 bar). Please order suitable sensor adapter (ADA-XX) separately. |
595 |
203755 |
Xylem WTW |
ESS 700 VA/N Stainless steel (1.4571) weld-in socket, for measurements in pipelines, for use with all sensors of 650/690/700(IQ)/701(IQ) series. Please order suitable sensor adapter (ADA-XX) separately. |
577 |
203757 |
Xylem WTW |
ESS 700 VA/10 Stainless steel weld-in socket, for measurements in pipelines with up to 10 bar pressure, useable for all series 650/690/700(IQ)/701(IQ) sensors. Please order suitable sensor adapter (ADA-XX) separately. |
832 |
203761 |
Xylem WTW |
ADA-DF 1 Adapter for mounting IQ sensors for measuring of pH/ORP, conductivity and D.O. in D 700/N or DMS/N flow-through vessels |
220 |
203767 |
Xylem WTW |
ADA-DF 4 Adapter for mounting D.O. sensors TriOxmatic® 702 and TriOxmatic® 702 IQ in D 702/N flow-thru vessel |
148 |
203771 |
Xylem WTW |
ADA-DF 6 Adapter for mounting D.O. sensor TriOxmatic® 702 IQ in flow-thru vessel D 702/N |
47.6 |
203773 |
Xylem WTW |
ADA-DF 7 Adapter for mounting turbidity sensor VisoTurb® 700 IQ in DMS/N flow-through vessel |
288 |
203777 |
Xylem WTW |
ADA-DF 9 Adapter for mounting IQ sensors for pH/ORP, D.O., conductivity, turbidity and suspended solids in flow-through vessels EBS(T)700-DU/N or ESS 700-VA/N |
220 |
203779 |
Xylem WTW |
ADA-DF 10 Adapter for mounting of pH/ORP armature SensoLyt® 690/700 in flow-thru vessels EBS(T)700-DU/N or ESS 700-VA/N |
132 |
203781 |
Xylem WTW |
ADA-DF 11 Adapter for mounting IQ sensors for pH/ORP, D.O., conductivity, turbidity and suspended solids in ESS 700 VA/10 weld-in socket |
377 |
203783 |
Xylem WTW |
ADA-DF 12 Adapter for mounting sensors TriOxmatic® 690/ 70X, CellOx® 700 and TetraCon® 700 in ESS 700 VA/10 weld-in socket |
174 |
203787 |
Xylem WTW |
ADA-DF 14 Adapter for mounting IQ sensor FDO®700 IQ in flow-thru vessel D 700/N |
291 |
203789 |
Xylem WTW |
ADA-DF 15 Adapter for mounting IQ sensor FDO®700 IQ in flow-thru vessels EBS 700-DU/N, EBST 700-DU/N and ESS 700 VA/N |
501 |
205200 |
Xylem WTW |
RL-AG/Oxi Cleaning solution for the silver anode of DO sensors of TriOxmatic® series, 1 bottle with 50 ml. |
96 |
205212 |
Xylem WTW |
ELY/A Electrolyte for D.O. sensors series TriOxmatic® 600/601/690/700 (IQ)/701 (IQ)/702 (IQ) Included: 1 bottle with 50 ml |
68 |
205253 |
Xylem WTW |
MSK FDO Membrane protective cap, provides protection against fishes and rock slide etc. for FDO® 70X IQ and FDO® 70X IQ SW series. |
153 |
205254 |
Xylem WTW |
MSK FDO® CS Cleaning set for FDO® 70X IQ SW and FDO® 70X IQ in combination with MSK FDO® |
114 |
291230 |
Xylem WTW |
Oxi 298 NTC Monitor for direct connection of analogue oxygen sensors, with 2 analog and relay outputs, Modbus, 115V/230V and NTC |
1433 |
300944EX |
Xylem WTW |
Stratos Pro A 201 X Cond-0 Conductivity transmitter for hazardous areas (II 2(1)G Ex ib[ia] IIC T4) with 1 analog current output. |
2620 |
300945EX |
Xylem WTW |
Stratos Pro A 201 X Cond-1 Conductivity transmitter for hazardous areas (II 2(1)G Ex ib[ia] IIC T4) with 2 analog current outputs. |
3074 |
302220 |
Xylem WTW |
LRD 01-1,5 2 electrode screw-in conductivity cell, 1/2 inch NPT, for use with analogue monitors. With integrated temperature sensor, 1.5 m (4.9 ft) cable and watertight plug (IP68) |
942 |
302222 |
Xylem WTW |
LRD 01-7 2 electrode screw-in conductivity cell, 1/2 inch NPT, for use with analogue monitors. With integrated temperature sensor, 7 m (23 ft) cable and watertight plug (IP68) |
1005 |
302225 |
Xylem WTW |
LRD 325-1,5 4 electrode screw-in conductivity cell, 1/2 inch NPT, for use with analogue monitors. With integrated temperature sensor, 1.5 m (4.9 ft) cable and watertight plug (IP68) |
746 |
302229 |
Xylem WTW |
LRD 325-7 4 electrode screw-in conductivity cell, 1/2 inch NPT, for use with analogue monitors. With integrated temperature sensor, 7 m (23 ft) cable and watertight plug (IP68) |
809 |
302316 |
Xylem WTW |
TetraCon® 700-7 Universal 4 electrode conductivity cell especially for waste water treatment plants, for use with EcoLine® and QuadroLine® monitors. With integrated temperature sensor, 7 m (23 ft) cable and watertight plug (IP68) |
1371 |
302316EX |
Xylem WTW |
TetraCon® 700-7 EX Analog 4 electrode conductivity cell for hazardous areas (Ex ib IIC T6 Gb X), for use with StratosProA201XCond-0(-1). With integrated temperature sensor and 7m cable with open cable ends. |
1668 |
302318 |
Xylem WTW |
TetraCon® 700-15 Universal 4 electrode conductivity cell especially for waste water treatment plants, for use with EcoLine® and QuadroLine® monitors. With integrated temperature sensor, 15 m (49 ft) cable and watertight plug (IP68) |
1510 |
302500 |
Xylem WTW |
TetraCon® 700 IQ Digital 4 electrode conductivity cell, especially for heavily polluted wastewater, for use with the IQ SENSOR NET System. With integrated temperature sensor, without cable (Please order SACIQ separately) |
1493 |
302501 |
Xylem WTW |
TetraCon® 700 IQ SW Digital 4 electrode conductivity cell, in seawater design, suited for heavily polluted water, for use with the IQ SENSOR NET. With integrated temperature sensor, without cable (Please order SACIQ separately) |
1691 |
303202 |
Xylem WTW |
ADA-G 1” V4A-stainless steel (1.4571) muffle ½ inch NPT to G1 inch thread |
109 |
303203 |
Xylem WTW |
ADA-LF-DN 20 PVC glue-in socket with ½ inch thread for installation of LRD 01/LRD 325 in DN 20 pipes |
66 |
303209 |
Xylem WTW |
EST-LRD V4A-stainless steel (1.4571) weld-in socket ½ inch NPT for installation of LRD 01 or LRD 325 conductivity sensor in pipes. |
46.3 |
303212 |
Xylem WTW |
ADA/AMPH-LAB-LF Adapter for mounting of laboratory conductivity cells to analogue monitors of series LF 170. |
149 |
303215 |
Xylem WTW |
ADA/AMPH-LF Adapter for direct mounting of conductivity cells series TetraCon® 700 and LRD to analogue monitors of series LF 29X |
126 |
303216 |
Xylem WTW |
ADA/LAB-LF Adapter for mounting of laboratory conductivity cells to analogue monitors of series LF 29X |
134 |
391230 |
Xylem WTW |
LF 298 NTC Monitor for direct connection of analogue conductivity measuring cells, with 2 analog and relay outputs, Modbus,115V/230V and NTC |
1499 |
470020 |
Xylem WTW |
MIQ/TC 2020 3G Module IQ Terminal/Controller, configurable as controller (permanently installed) or as terminal with redundant controller function for system 2020, with USB interface, for coupling to any IQ SENSOR NET module |
2740 |
470021 |
Xylem WTW |
Terminal IQ Terminal for the IQ SENSOR NET System 2020, portable terminal with large, colored display, robust buttons and USB interface, without controller(-BackUp) function |
1374 |
470022 |
Xylem WTW |
MIQ/TC 2020 3G-CR3 Multi-parameter measuring converter, for connecting up to 20 IQ sensors. Scope of supply: MIQ/TC 2020 3G Terminal/Controller, MIQ/CR3 with 3 analog outputs (0/4- 20 mA) and 3 relays, MIQ/PS wide-range power supply |
4029 |
470024 |
Xylem WTW |
MIQ/TC 2020 3G-C6 Multi-parameter measuring converter, for connecting up to 20 IQ sensors. Scope of supply: MIQ/TC 2020 3G Terminal/Controller, MIQ/C6 with 6 analog outputs (0/4-20 mA), MIQ/PS wide-range power supply |
4029 |
470026 |
Xylem WTW |
MIQ/TC 2020 3G-EF Multi parameter Controller to connect up to 20 IQ sensors. Scope of delivery: MIQ/TC 2020 3G Terminal/Controller, MIQ/MC3 Controller with Ethernet interface (Modbus TCP, Ethernet/IP, PROFINET), MIQ/PS wide range power supply |
4509 |
471020 |
Xylem WTW |
MIQ/MC3 Module IQ/microcontroller for system 2020, for up to 20 IQ sensors, in module housing, with automatic air pressure compensation, USB interface (IP66), Ethernet RJ45 interface (IP 66) |
1572 |
471022 |
Xylem WTW |
MIQ/MC3-MOD Module IQ/microcontroller for system 2020, for up to 20 IQ sensors, with MODBUS connection, automatic air pressure compensation as well as USB interface (IP 66) and Ethernet interface (IP 66) (Please order separately D-SUB connection ADA/D-SUB 902888) |
3384 |
471023 |
Xylem WTW |
MIQ/MC3-PR Module IQ/microcontroller for system 2020, for up to 20 IQ sensors, with PROFIBUS connection, automatic air pressure compensation as well as USB interface (IP 66) and Ethernet interface (IP 66) (Please order separately D-SUB connection ADA/D-SUB 902888) |
3550 |
471026 |
Xylem WTW |
MIQ/3-MOD Module IQ with MODBUS connection and automatic air pressure compensation (can be used only with MIQ/TC 2020 3G) (Please order separately D-SUB connection ADA/D-SUB 902888) |
2721 |
471027 |
Xylem WTW |
MIQ/3-PR Module IQ with PROFIBUS connection and automatic air pressure compensation (can be used only with MIQ/TC 2020 3G) (Please order separately D-SUB connection ADA/D-SUB 902888) |
2945 |
472005 |
Xylem WTW |
DIQ/JB Dual IQ/Junction box for connection of a second or an IQ sensor in bigger distance to the system 28X |
95 |
472007 |
Xylem WTW |
DIQ/CHV Dual IQ/Cleaning Head Valve for automatic air cleaning controlled by a relay, for system 28X, (relay and compressed air supply external) |
505 |
472103 |
Xylem WTW |
DIQ/S 281-CR2 Universal Transmitter to operate up 1 digital IQ sensor, with 2 x 0(4) … 20 mA, 2 x Relays |
925 |
472104 |
Xylem WTW |
DIQ/S 281-CR2/24V Universal Transmitter to operate 1 digital IQ sensor, with 2 x 0(4) … 20 mA, 2 x Relays, for 24 V AC/DC power supply |
1044 |
472105 |
Xylem WTW |
DIQ/S 281-MOD Dual IQ/System 281, universal controller to connect 1 digital IQ sensor with Modbus RTU and 2 relays, 100 ... 240 VAC |
1208 |
472106 |
Xylem WTW |
DIQ/S 281-HART Dual IQ/System 281, universal controller to connect 1 digital IQ sensor with HART and 2 relays, 100 ... 240 VAC |
2355 |
472110 |
Xylem WTW |
DIQ/S 282-CR3 Universal Transmitter to operate up to 2 digital IQ sensors, with 3 x 0(4) … 20 mA, 3 x Relays |
2173 |
472111 |
Xylem WTW |
DIQ/S 282-PR Universal Transmitter to operate up to 2 digital IQ sensors, with PROFIBUS-connection, 3 x Relays (Please order separately D-SUB connection ADA/D-SUB 902 888) |
2611 |
472112 |
Xylem WTW |
DIQ/S 282-MOD Universal Transmitter to operate up to 2 digital IQ sensors, with MODBUS-connection, 3 x Relays (Please order separately D-SUB connection ADA/D-SUB 902 888) |
2582 |
472113 |
Xylem WTW |
DIQ/S 282-CR3-E Universal Transmitter to operate up to 2 digital IQ sensors, with 3 x 0(4) … 20 mA, 3 x Relays, with RJ45 interface for internet connection and remote control |
2611 |
472114 |
Xylem WTW |
DIQ/S 282-EF Universal Transmitter to operate up to 2 digital IQ sensors, with Ethernet fieldbuses, internet connection and remote control, 3 x Relays |
2611 |
472120 |
Xylem WTW |
DIQ/S 282-CR3/24V Universal Transmitter to operate up to 2 digital IQ sensors, with 3 x 0(4) … 20 mA, 3 x Relays, for 24 V AC/DC power supply |
2325 |
472121 |
Xylem WTW |
DIQ/S 282-PR/24V Universal Transmitter to operate up to 2 digital IQ sensors, with PROFIBUS-connection, 3 x Relays, for 24 V AC/DC power supply (Please order separately D-SUB connection ADA/D-SUB 902 888) |
2797 |
472122 |
Xylem WTW |
DIQ/S 282-MOD/24V Universal Transmitter to operate up to 2 digital IQ sensors, with MODBUS-connection, 3 x Relays, for 24 V AC/DC power supply (Please order separately D-SUB connection ADA/D-SUB 902 888) |
2761 |
472123 |
Xylem WTW |
DIQ/S 282-CR3-E/24V Universal Transmitter to operate up to 2 digital IQ sensors, with 3 x 0(4) … 20 mA, 3 x Relays, with RJ45 interface for internet connection and remote control, for 24 V AC/DC power supply |
2797 |
472124 |
Xylem WTW |
DIQ/S 282-EF/24V Universal Transmitter to operate up to 2 digital IQ sensors, with Ethernet fieldbuses, internet connection and remote control, 3 x Relays, for 24 V AC/DC power supply |
2797 |
472130 |
Xylem WTW |
DIQ/S 284-CR6 Universal Transmitter to operate up to 4 digital IQ sensors, with 6 x 0(4) … 20 mA, 6 x Relays |
2834 |
472131 |
Xylem WTW |
DIQ/S 284-PR Universal Transmitter to operate up to 4 digital IQ sensors, with PROFIBUS-connection, 3 x Relays (Please order separately D-SUB connection ADA/D-SUB 902 888) |
3024 |
472132 |
Xylem WTW |
DIQ/S 284-MOD Universal Transmitter to operate up to 4 digital IQ sensors, with MODBUS-connection, 3 x Relays (Please order separately D-SUB connection ADA/D-SUB 902 888) |
2950 |
472133 |
Xylem WTW |
DIQ/S 284-CR6-E Universal Transmitter to operate up to 4 digital IQ sensors, with 6 x 0(4) … 20 mA, 6 x Relays, with RJ45 interface for internet connection and remote control |
3024 |
472134 |
Xylem WTW |
DIQ/S 284-EF Universal Transmitter to operate up to 4 digital IQ sensors, with Ethernet fieldbuses, internet connection and remote control, 3 x Relays |
3024 |
472140 |
Xylem WTW |
DIQ/S 284-CR6/24V Universal Transmitter to operate up to 4 digital IQ sensors, with 6 x 0(4) … 20 mA, 6 x Relays, for 24 V AC/DC power supply |
3034 |
472141 |
Xylem WTW |
DIQ/S 284-PR/24V Universal Transmitter to operate up to 4 digital IQ sensors, with PROFIBUS-connection, 3 x Relays, for 24 V AC/DC power supply (Please order separately D-SUB connection ADA/D-SUB 902 888) |
3234 |
472142 |
Xylem WTW |
DIQ/S 284-MOD/24V Universal Transmitter to operate up to 4 digital IQ sensors, with MODBUS-connection, 3 x Relays, for 24 V AC/DC power supply (Please order separately D-SUB connection ADA/D-SUB 902 888) |
3153 |
472143 |
Xylem WTW |
DIQ/S 284-CR6-E/24V Universal Transmitter to operate up to 4 digital IQ sensors, with 6 x 0(4) … 20 mA, 6 x Relays, with RJ45 interface for internet connection and remote control, for 24 V AC/DC power supply |
3234 |
472144 |
Xylem WTW |
DIQ/S 284-EF/24V Universal Transmitter to operate up to 4 digital IQ sensors, with Ethernet fieldbuses, internet connection and remote control, 3 x Relays, for 24 V AC/DC power supply |
3234 |
480004 |
Xylem WTW |
MIQ/PS Module IQ/Power Supply, wide-range power supply for system 2020 and 28X, power output max. 18 W, 3 idle IQ SENSOR NET connections |
589 |
480006 |
Xylem WTW |
MIQ/24V Module IQ/24V, power supply for 24 VAC / 24 VDC input voltage, for system 2020 and 28X, power output max. 18 W, 3 idle IQ SENSOR NET connections |
826 |
480008 |
Xylem WTW |
MIQ/JB Module IQ/Junction Box for system 2020 and 28X, 4 idle IQ SENSOR NET connections |
345 |
480010 |
Xylem WTW |
MIQ/JBR Module IQ/Junction Box Repeater for system 2020, with integrated bidirectional signal amplifier (repeater) |
513 |
480013 |
Xylem WTW |
MIQ/R6 Module IQ/Relais 6, for system 2020 and 282/284, with 6 relays (240 VAC/2 A) |
1043 |
480014 |
Xylem WTW |
MIQ/CR3 Module IQ/Current Relais 3, for System 2020 and 28X, with 3 analog (0/4-20 mA) and 3 relay outputs (250 VAC/5 A) |
1064 |
480015 |
Xylem WTW |
MIQ/C6 Module IQ/Current 6, for system 2020 and 28X, with 6 (0) 4 - 20 mA outputs |
1064 |
480016 |
Xylem WTW |
MIQ/IC2 Module IQ/input current with 2 (0) 4 - 20 mA inputs, for system 2020 and 282/284 |
1292 |
480017 |
Xylem WTW |
Cleaning Air Box - 115 VAC Air pressure compressor for online sensors. For easy wall mounting, switchable by a relay to provide cleaning systems with air pressure. 115 VAC. No additional CHV PLUS needed. |
1785 |
480018 |
Xylem WTW |
MIQ/CHV PLUS Module IQ/Cleaning Head Valve, for automatic air cleaning controlled by a relay or the IQ SENSOR NET (relay and compressed air supply external) |
863 |
480019 |
Xylem WTW |
Cleaning Air Box - 230 VAC Air pressure compressor for online sensors. For easy wall mounting, switchable by a relay to provide cleaning systems with air pressure. 230 VAC. No additional CHV PLUS needed. |
1785 |
480023 |
Xylem WTW |
MIQ/WL PS Module IQ Wireless, for cable free communication within the IQ Sensor Net System 28X and System 2020. Extension module for starter set MIQ/WL PS SET (480025). |
1513 |
480025 |
Xylem WTW |
MIQ/WL PS SET Modul IQ/Wireless, for cable free communication within the IQ Sensor Net System 28X and System 2020. Starterset consists of 1 Master and 1 Slave. Extension with MIQ/WL PS (480023) possible. |
3018 |
480026 |
Xylem WTW |
AF/Cleaning Air Box Air intake filter for Cleaning Air Box. For the removal of particles to maintain the compressor. |
88 |
480027 |
Xylem WTW |
RM/Cleaning Air Box Replacement membrane for compressor in Cleaning Air Box. The membrane should be replaced after 5000 h of operation time or after 5 years. |
158 |
480040 |
Xylem WTW |
SACIQ-1,5 Sensor adapter cable for all IQ sensors, with IP 68 waterproof connection to the IQ SENSOR NET system. Cable length 1.5 m (4.9 ft) |
174 |
480041V*** |
Xylem WTW |
SACIQ-SO Sensor adapter cable for all IQ sensors, with IP 68 waterproof connection to the IQ SENSOR NET system. Customized cable length up to 100 m (330 ft) |
213 |
480042 |
Xylem WTW |
SACIQ-7,0 Sensor adapter cable for all IQ sensors, with IP 68 waterproof connection to the IQ SENSOR NET system. Cable length 7 m (23 ft) |
219 |
480044 |
Xylem WTW |
SACIQ-15,0 Sensor adapter cable for all IQ sensors, with IP 68 waterproof connection to the IQ SENSOR NET system. Cable length 15 m (49 ft) |
269 |
480045 |
Xylem WTW |
SACIQ-20,0 SW Sensor adapter cable for all IQ sensors, in seawater design, with IP 68 waterproof connection to the IQ SENSOR NET system. Cable length 20 m (65 ft), with screwable SACIQ-Plug |
378 |
480046V |
Xylem WTW |
SNCIQ - SO Specific two-wire IQ SENSOR NET cable with shield for safe power/information transfer within the IQ SENSOR NET system. Please indicate cable length in m when ordering (unit: m) |
9.4 |
480047V |
Xylem WTW |
SNCIQ/UG- SO Specific two-wire IQ SENSOR NET cable with shield for safe power/information transfer within the IQ SENSOR NET system, esp. for use in underground Please indicate cable length in m when ordering (unit: m) |
13.6 |
480048 |
Xylem WTW |
PMS/IQ Kit for panel mounting of IQ SENSOR NET modules |
44.6 |
480049 |
Xylem WTW |
PMS/IQ-X PMS/IQ-X - for panel mounting of IQ SENSOR NET System 282/284. Recommended for versions with -PR, -MOD or -E(F). |
165 |
480050 |
Xylem WTW |
THS/IQ Kit for top hat rail mounting of IQ SENSOR NET modules |
29.3 |
480051 |
Xylem WTW |
EW/1 Set of 4 cable glands M20 required for cable sheaths with an outside diameter of more than 10 mm. |
35.7 |
480052 |
Xylem WTW |
WMS/IQ Kit for wall mounting of IQ SENSOR NET modules |
13.2 |
480060 |
Xylem WTW |
SACIQ-50,0 SW Sensor adapter cable for all IQ sensors, in seawater design, with IP 68 waterproof connection to the IQ SENSOR NET system. Cable length 50 m (162 ft), with screwable SACIQ-Plug |
624 |
480064V*** |
Xylem WTW |
SACIQ-SO SW Sensor adapter cable for all IQ sensors, in seawater design, with IP 68 waterproof connection to the IQ SENSOR NET system. Customized cable length up to 100 m (330 ft), with screwable SACIQ-Plug |
295 |
480065 |
Xylem WTW |
SACIQ-Plug Screwable plug for all SACIQ sensor adapter cables for IQ sensors |
26.5 |
480066 |
Xylem WTW |
SACIQ-25,0 SW Sensor adapter cable for all IQ sensors, in seawater design, with IP 68 waterproof connection to the IQ SENSOR NET system. Cable length 25 m (82 ft), with screwable SACIQ-Plug |
411 |
480068 |
Xylem WTW |
SNCIQ-100 Specific two-wire IQ SENSOR NET cable with shield for safe power/information transfer within the IQ SENSOR NET system. Cable reel with 100 m (109 yds) |
835 |
480069 |
Xylem WTW |
SNCIQ-200 Specific two-wire IQ SENSOR NET cable with shield for safe power/information transfer within the IQ SENSOR NET system. Cable reel with 200 m (119 yds) |
1672 |
480070 |
Xylem WTW |
SNCIQ-250 Specific two-wire IQ SENSOR NET cable with shield for safe power/information transfer within the IQ SENSOR NET system. Cable reel with 250 m (273 yds) |
2103 |
480072 |
Xylem WTW |
SNCIQ-500 Specific two-wire IQ SENSOR NET cable with shield for safe power/information transfer within the IQ SENSOR NET system. Cable reel with 500 m (547 yds). |
4201 |
480075 |
Xylem WTW |
SNCIQ/UG-250 Specific two-wire IQ SENSOR NET cable with shield for safe power/information transfer within the IQ SENSOR NET system, esp. for use in underground. Cable reel with 250 m (273 yds). |
2958 |
480080 |
Xylem WTW |
VIS FT-1 Flow-through measurimg cell for spectral UV and UV-VIS sensors, for operation with automatic compressed air cleaning |
2001 |
480081 |
Xylem WTW |
VIS FT-1/RS Spare part set for flow-thru measuring cell VIS FT-1 |
52 |
480100 |
Xylem WTW |
WA 700/10 Retractable armature for measurements in pipelines, with up to 10 bar overpressure, for use with all series 650/ 690/700(IQ)/701(IQ) sensors. Consisting of a pre-assembled armature with ball valve, mounting aid up to 10 bar, rinsing connectors and a sensor sleeve with sealings and retainer rings. Please order suitable sensor adapter separately. |
3697 |
480100EX |
Xylem WTW |
WA 700/10 EX Retractable armature up to 10 bar |
4435 |
480102 |
Xylem WTW |
WA 700/2 Retractable armature for measurements in pipelines, with up to 2 bar overpressure, for use with all series 650/ 690/700(IQ)/701(IQ) sensors. Consisting of a pre-assembled armature with ball valve, mounting aid up to 2 bar, rinsing connectors and a sensor sleeve with sealings and retainer rings. Please order suitable sensor adapter separately. |
2600 |
480102EX |
Xylem WTW |
WA 700/2 EX Retractable armature up to 2 bar |
3119 |
480104 |
Xylem WTW |
ESS-WA 700/ST Steel (St 33) weld-in socket for WA 700/2 und WA 700/10 retractable armatures |
95 |
480106 |
Xylem WTW |
ESS-WA 700/VA Stainless steel (1.4571) weld-in socket for WA 700/2 und WA 700/10 retractable armatures |
74 |
480108 |
Xylem WTW |
ADA-WA 1 Adapter for mounting of IQ sensors for pH/ORP, conductivity, D.O., turbidity and TSS into WA 700/2 and WA 700/10 retractable armatures |
129 |
480110 |
Xylem WTW |
ADA-WA 2 Adapter for mounting of IQ sensors TriOxmatic® 690/70X and TetraCon® 700 into WA 700/2 and WA 700/10 retractable armatures |
148 |
480112 |
Xylem WTW |
ADA-WA 3 Adapter for mounting of pH/ORP armature SensoLyt® 650/690/700 into WA 700/2 and WA 700/10 retractable armatures |
160 |
480114 |
Xylem WTW |
ADA-WA 4 Adapter for mounting of IQ sensor FDO®700 IQ into WA 700/2 and WA 700/10 retractable armatures |
362 |
480116 |
Xylem WTW |
WA/BV Blind plug for weld-in socket fittings ESS-WA 700/ST and ESS-WA 700/VA |
93 |
480118 |
Xylem WTW |
WA/Epack Spare set of O-ring seals for retractable armatures WA 700/2 and WA 700/10 |
66 |
481034 |
Xylem WTW |
UV 701 IQ NOx Optical Nitrate (NOx) sensor with single wavelength measurement, for measurement of higher concentrations in wastewater and surface water, with turbidity compensation and integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately) |
12676 |
481035 |
Xylem WTW |
UV 705 IQ NOx Optical Nitrate (NOx) sensor with single wavelength measurement, for measurement of lower concentrations in wastewater and surface water, with turbidity compensation and integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
12676 |
481036 |
Xylem WTW |
UV 701 IQ SAC Optical SAC and UVT sensor (254 nm), for measurement of higher concentrations in wastewater and surface water, with turbidity compensation and integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
11936 |
481038 |
Xylem WTW |
UV 705 IQ SAC Optical SAC and UVT sensor (254 nm), for measurement of lower concentrations in wastewater and surface water, with turbidity compensation and integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
11936 |
481044 |
Xylem WTW |
NitraVis 701 IQ Spectral nitrate sensor ( 60 mm) with spectral processing of UV-VIS range, for measurement in inlet/BNR part of municipal wastewater treatment plants, with integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
17584 |
481045 |
Xylem WTW |
NitraVis 701 IQ TS Spectral nitrate/TSS sensor (60 mm) with spectral processing of UV-VIS range, for in-situ measurement in inlet/ BNR part of municipal wastewater treatment plants, with integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
20521 |
481046 |
Xylem WTW |
NitraVis 705 IQ Spectral nitrate sensor (60 mm) with spectral processing of UV-VIS range, for measurement in the effluent of municipal wastewater treatment plants, with integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
17584 |
481047 |
Xylem WTW |
NitraVis 705 IQ TS Optical nitrate/TSS sensor (60 mm) with spectral processing of UV-VIS range, for measurement in the effluent of municipal wastewater treatment plants, with integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
20521 |
481048 |
Xylem WTW |
CarboVis 701 IQ Optical COD/TOC/DOC/BOD or SAC sensor (60 mm) with spectral processing of the UV-VIS range, for measurement in the inlet/effluent/BNR part of municipal wastewater treatment plants, with integrated integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
21969 |
481049 |
Xylem WTW |
CarboVis 701 IQ TS Optical COD/TOC/DOC/BOD/SAC and TSS sensor (60 mm) with spectral processing of the UV-VIS range, for measurement in the inlet/effluent/aeration part of municipal wastewater treatment plants with integrated integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
24905 |
481050 |
Xylem WTW |
CarboVis 705 IQ Optical COD/TOC/DOC/BOD or SAC sensor (60 mm) with spectral processing of the UV-VIS range, for measurement in the effluent of municipal wastewater treatment plants, with integrated integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
21969 |
481051 |
Xylem WTW |
CarboVis 705 IQ TS Optical COD/TOC/DOC/BOD/SAC and TSS sensor (60 mm) with spectral processing of the UV-VIS range, for measurement in the effluent of municipal wastewater treatment plants, with integrated integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
24905 |
481052 |
Xylem WTW |
NiCaVis 705 IQ Spectral UV-VIS sensor (60 mm) for measurement of Nitrate, CODtotal, CODsoluble, TOC, BOD, DOC, SACtotal, SACsoluble, and UVT254 , for measurement in the effluent of municipal wastewater treatment plants, with integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
26352 |
481053 |
Xylem WTW |
NiCaVis 705 IQ TS Spectral UV-VIS sensor (60 mm) for measurement of Nitrate, CODtotal, CODsoluble, TOC, BOD, DOC, SACtotal, SACsoluble, UVT254 and TSS , for measurement in the effluent of municipal wastewater treatment plants, with integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
29287 |
481054 |
Xylem WTW |
NiCaVis 701 IQ NI Spectral UV sensor (60 mm) for measurement of Nitrite, Nitrate, CODtotal, CODsoluble, TOC, BOD, DOC, SACtotal, SAC soluble, and UVT254 in the influent, biological tank and effluent of municipal waste water treatment plants, with integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
27233 |
481055 |
Xylem WTW |
NiCaVis 705 IQ NI Spectral UV sensor (60 mm) for measurement of Nitrite, Nitrate, CODtotal, CODsoluble, TOC, BOD, DOC, SACtotal, SACsoluble, and UVT254 in the effluent of municipal waste water treatment plants, with integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately) |
27233 |
481056 |
Xylem WTW |
NitraVis 701 IQ NI Spectral UV sensor (60 mm) for measurement of Nitrite and Nitrate in the influent, biological tank and effluent of municipal waste water treatment plants, with integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
18469 |
481057 |
Xylem WTW |
NitraVis 705 IQ NI Spectral UV sensor (60 mm) for measurement of Nitrite and Nitrate in the effluent of municipal wastewater treatment plants, with integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately). |
18469 |
481058 |
Xylem WTW |
NiCaVis 705 IQ SF Spectral UV-VIS sensor (60 mm) for the measurement of Nitrate, COD, TOC, BOD, DOC, SAC, UVT254 and TS in surface water bodies with integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately) |
26352 |
481059 |
Xylem WTW |
NiCaVis® 705 IQ NI SF Spectral UV-VIS sensor (60 mm) for the measurement of Nitrate, Nitrite, COD, TOC, BOD, DOC, SAC and UVT254 in surface water bodies with integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately) |
27233 |
481060 |
Xylem WTW |
NiCaVis 705 IQ SF Co Spectral UV-VIS probe to measure Nitrate, Color, CODdiss., TOC, BOD, DOC, SAC and UVT254 in surface waters with integrated ultrasonic cleaning, multifunctional slide and shock-absorption-rings (order SACIQ separately) |
24664 |
481065 |
Xylem WTW |
CarboVis 705 IQ TS Co Spectral UV-VIS probe for measuring color, CODtot, CODdiss., TOC, BOD, DOC, SACtot., SACdiss., UVT254 and TSS in a WWTP drain/outlet with integrated ultrasonic cleaning, multifunctional slide and shock-absorption-rings (order SACIQ separately) |
26155 |
481066 |
Xylem WTW |
NiCaVis 705 IQ TS Co Spectral UV-VIS probe for measuring color, nitrate, CODtot, CODdiss., TOC, BOD, DOC, SACtot., SACdiss. and UVT254 in a WWTP drain/outlet with integrated ultrasonic cleaning, multifunctional slide and shock-absorption-rings (order SACIQ separately) |
30538 |
481067 |
Xylem WTW |
ColorVis 705 IQ Spectral UV-VIS probe for measuring color (Hazen 340, 390, 445, 455, 465, ISO 410) with integrated ultrasonic cleaning, multifunctional slide and shock-absorption-rings (order SACIQ separately) |
11936 |
481071 |
Xylem WTW |
VIS/CT Universal cleaning tool for spectral sensors. |
82 |
481073 |
Xylem WTW |
VIS Set/EH Supplement kit for spectral sensors for horizontal mounting of a UV/VIS sensor, with the EH/F 170 swing mounting assembly for use in basins or open channels. |
301 |
481074 |
Xylem WTW |
VIS/CV Multifunctional slide for spectral sensors. |
267 |
481075 |
Xylem WTW |
SET/AP Air pressure cleaning set for spectral sensors: Supplied with 15 m (49 ft) tubing, fittings, without further modules and components. |
133 |
481077 |
Xylem WTW |
ST-1 Standard with low concentration for 5 mm spectral sensors. |
80 |
481078 |
Xylem WTW |
ST-2 Standard with high concentration for 1 mm specrtal sensors. |
60 |
481079 |
Xylem WTW |
VIS/CS Universal cleaning tool set for cleaning of measuring windows of spectral sensors with cleaning solutions. |
223 |
481080 |
Xylem WTW |
VIS Set-F Supplement kit for horizontal mounting of a UV-VIS/UV sensor. For use in variable water levels with the S 200 float. |
423 |
481200 |
Xylem WTW |
IFL 700 IQ Digital ultrasonic sensor (60 mm) with automatic cleaning for interface level detection. Included: Sensor without sensor connection cable (please order SACIQ separately) |
7705 |
481206 |
Xylem WTW |
IFL-E Deflector armature for IFL 700 IQ and IFL 701 IQ for application with surface skimmers |
443 |
481207 |
Xylem WTW |
IFL-RM Rail mount for interface level sensors IFL 700 IQ and IFL 701 IQ in combination with deflector armature IFL-E. (EH/WT-D30, IFL-E please order separately) |
1350 |
503200 |
Xylem WTW |
PB-W/230V Compact sampler 230 V (50/60 Hz) for wall mounting |
2881 |
503201 |
Xylem WTW |
PB-W/115V Compact sampler 115 V (50/60 Hz) for wall mounting |
2881 |
503225 |
Xylem WTW |
PB-S/1 Sampler 230 V/50 Hz, with Stainless Steel housing for high ambient temperatures, with 1 x 25 l PE sample container. Supplied with 5 m (16.2 ft) suction tubing (without tubing end piece). |
8004 |
503228 |
Xylem WTW |
PB-S/R12 Sampler 230 V/50 Hz, with Stainless Steel housing for high ambient temperatures, with 12 x 2.9 l PE container. Supplied with 5 m (16.2 ft) suction tubing (without tubing end piece). |
8839 |
503230 |
Xylem WTW |
PB-S/R24 Sampler 230 V/50 Hz, with Stainless Steel housing for high ambient temperatures, with 24 x 1 l PE container. Supplied with 5 m (16.2 ft) suction tubing (without tubing end piece). |
8994 |
503250 |
Xylem WTW |
PB-M-S/1 Compact portable sampler with integrated rechargeable battery and 1 x 13 L PE sample container. Supplied with 5 m (16.2 ft) suction tubing, fitting and tubing end piece. Battery charger is not included. |
3774 |
503280 |
Xylem WTW |
PB-M-L/R24 Portable sampler with integrated rechargeable battery and 24 x 1 l PE container. Supplied with 5 m (16.2 ft) suction tubing, fitting and tubing end piece. Battery charger is not included. |
4804 |
503303 |
Xylem WTW |
1/PB-S 1 L PE sample bottle with sealing cap for PB-S/R24. |
13 |
503304 |
Xylem WTW |
1/PB-M-L 1 L PE sample bottle (segment) for PB-M-L/R24. |
12.3 |
503307 |
Xylem WTW |
2,9/PB-S 2.9 L PE sample bottle with sealing cap for PB-S/R12. |
14.6 |
503311 |
Xylem WTW |
13/PB 13 L PE collection container for PB-W and PB-M-S/1. |
63 |
503314 |
Xylem WTW |
25/PB 25 L PE collection container for the PB series. |
83 |
503337 |
Xylem WTW |
Schlauch/10mm/PB/1 PVC suction tubing, 10mm I.D., fabric reinforced, per meter |
16.4 |
503338 |
Xylem WTW |
Schlauch/12mm/PB-S PVC suction tubing, 12mm I.D., fabric reinforced, per meter |
16.3 |
503339 |
Xylem WTW |
SR/180mm/PB Suction piece V2A, length 180 mm, for tubing 10 mm ID (503337). |
85 |
503340 |
Xylem WTW |
SR/180mm/PB-S Suction piece V2A, length 180mm, for tubing 10mm ID (503338) |
84 |
503341 |
Xylem WTW |
EVSR/PB Pick off-attachment to mount the suction tube, pendular or fixed (wall mounting in channel). |
407 |
503343 |
Xylem WTW |
SK/10mm/PB Strainer for suction piece SR/180 mm/PB (503339), 10 mm. |
272 |
503344 |
Xylem WTW |
SK/12mm/PB-S Strainer for suction piece SR/180mm/PB (503340), 12mm |
267 |
503361 |
Xylem WTW |
TP/PB-M Desiccant cartridge for PB-M |
82 |
503363 |
Xylem WTW |
USB/PB USB cable from USB 2 to mini USB for PB-M and PB-S. |
25.1 |
503371 |
Xylem WTW |
LG/65/PB-M Battery charger IP 65 for PB-M. |
473 |
503372 |
Xylem WTW |
EA/7,5/PB-M Rechargeable battery, 7.5 Ah for PB-M. |
213 |
503385 |
Xylem WTW |
SG/PB-S Stainless steel base frame, 40 cm x 70 cm x 41 cm, HxWxD for PB-S |
520 |
503387 |
Xylem WTW |
LED-in/PB-S LED interior lighting with door contact switch |
166 |
503389 |
Xylem WTW |
KFS/PB-W Capacitive level sensor (contact-free) for industrial applications for PB-W. |
418 |
503392 |
Xylem WTW |
VARDF/PB-S Option for variable dosage unit for flow-dependent sampling, 0 … 250 ml, for PB-S (additional price) |
1301 |
503420 |
Xylem WTW |
MK/10m/PB Flow signal cable with 10 m (open cable ends) for PB-M and PB-S. |
152 |
503427 |
Xylem WTW |
SSM/PB Collective fault message (always defined as the first message) |
87 |
505123 |
Xylem WTW |
S/CH Shackle for chain fitting |
15 |
505124**** |
Xylem WTW |
CH/SO Chain per meter.High tensile strength and UV-resistant. |
18.9 |
505544 |
Xylem WTW |
Kl/pH-MIQ/S Connection box as wallmounting device, for high impedance plug head electrode use on IQ SENSOR NET Systems. K 5 S and TFK 150/325 temperaturesensor separately necessary. Dimensions, W x H x D: 240 x 165 x 95 mm. Protection: IP 65 |
858 |
505572 |
Xylem WTW |
KI/LF-0,4/MIQ Connection box for 2- and 4-electrode conductivity cells with NTC for use with IQ SENSOR NET systems with a cell constant of 0.475 cm-1. For connection to laboratory-cells an adapter is required (303212 ADA AMPH LAB LF). Dimensions, W x H x D: 240 x 165 x 95 mm. Protection IP 65. |
952 |
600010 |
Xylem WTW |
VisoTurb® 700 IQ Digital turbidity sensor for drinking water/water and wastewater (ultrasonic cleaning) for use with the IQ SENSOR NET system. Please order connection cable SACIQ separately. |
3485 |
600011 |
Xylem WTW |
VisoTurb® 700 IQ SW Digital turbidity sensor for industrial and seawater applications (ultrasonic cleaning) for use with the IQ SENSOR NET system. Please order connection cable separately. |
4315 |
600012 |
Xylem WTW |
ViSolid® 700 IQ Digital suspended solids sensor for water/wastewater/sludge (ultrasonic cleaning) for use with the IQ SENSOR NET system. Please order connection cable SACIQ separately. |
4257 |
600013 |
Xylem WTW |
ViSolid® 700 IQ SW Digital suspended solids sensor for industrial and seawater applications (ultrasonic cleaning) for use with the IQ SENSOR NET system. Please order connection cable separately. |
5271 |
600014 |
Xylem WTW |
Standard 1000 FNU Standard with 1000 FNU for VisoTurb® 700 IQ. |
134 |
600015 |
Xylem WTW |
Standard 4000 FNU Standard with 4000 FNU for ViSolid® 700 IQ. |
220 |
810002 |
Xylem WTW |
SET1/PurCon® Set of pump tubing for PurCon® permeate pump. |
173 |
810005 |
Xylem WTW |
AF/PurCon® Spare air filter for PurCon® compressor LP-60HN. |
36.3 |
810015 |
Xylem WTW |
AF-N/PurCon Spare air filter for PurCon® compressor AP-60(N). |
36.3 |
810065 |
Xylem WTW |
PCIS-PL5/H Permeate line 5 m (16.2 ft) for PurCon® IS, with freeze protection. |
800 |
810066 |
Xylem WTW |
PCIS-PL10/H Permeate line 10 m (33 ft) for PurCon® IS, with freeze protection. |
1346 |
810067 |
Xylem WTW |
PCIS-PL20/H Permeate line 20 m (65 ft) for PurCon® IS, with freeze protection. |
2150 |
810117 |
Xylem WTW |
SW/P102 Exchange cutting unit for P102, P102/1 and FGT 615-2 top-and bottom part. |
400 |
820065 |
Xylem WTW |
FT/PC Filter module set (4 pieces) for PurCon® and PurCon® IS. |
3195 |
820066 |
Xylem WTW |
LSet/PC Set air tubing for PurCon®. |
101 |
820067 |
Xylem WTW |
SLSET/PC Piping Set for PurCon®. |
154 |
820068 |
Xylem WTW |
FT/PCIS-2 Filter module set (2 pieces) for PurCon® IS. |
1674 |
820069 |
Xylem WTW |
SLSet/PCIS Kit of tubes for PurCon® IS (inside of filter modules / controller unit). |
271 |
821004 |
Xylem WTW |
TC/ÜB 1 Overflow vessel for 1 parameter, for TresCon® systems. |
232 |
821017 |
Xylem WTW |
BEH/ T 1,5 1.5 l wide-necked bottle (with screw cap and labels). |
71 |
821019 |
Xylem WTW |
BEH/ T 10 10 l container (with screw cap and labels). |
88 |
821055 |
Xylem WTW |
BSet/A111 Container set for ammonium module OA 110, TresCon® A111 and TresCon® Uno TCU/A111. |
202 |
821057 |
Xylem WTW |
BSet/ N511 Container set for nitrite TresCon® module ON 510, TresCon® N511 and TresCon® Uno N511. Supplied with 2 x 1 l square bottle, incl. screw caps and labels. |
239 |
821058 |
Xylem WTW |
BSet/P211 Container set for analyzer module ammonia OA 110 resp. TresCon® A111 and TresCon® Uno TCU/A111. |
202 |
821059 |
Xylem WTW |
BSet/P511 Container set for total phosphor TresCon® module OP 510 (resp. TresCon® P511). |
308 |
821068 |
Xylem WTW |
KB/P511 Cooling box for Ptotal reagents for total phosphor TresCon® module. |
1953 |
821071 |
Xylem WTW |
R/ ADD/ TC Pack of Na2-EDTA powder (390 g) as reagent additive for 10 l. |
42.6 |
821075 |
Xylem WTW |
R/ A111 Pack of 390 g Na2-EDTA powder (for 10 l) and 400 g NaOH concentrate (pellets), for ammonium, nitrate, nitrite and orthophosphate TresCon®module. |
73 |
821085 |
Xylem WTW |
R/ N511 1 l reagent solution for nitrite analyzer module TresCon® ON 510 (resp. TresCon® N511 and TresCon® Uno TCU/N511), 13% phosphoric acid. |
302 |
821091 |
Xylem WTW |
R/ P211 10 l reagent solution for orthophosphate TresCon® module OP 210... (TresCon® P211... and TCU/P211..), 12?% salt acid. |
369 |
821096 |
Xylem WTW |
RD/P511 Reagent D for module OP 510 (resp. TresCon® P511). |
172 |
821097 |
Xylem WTW |
RC/P511 Reagent C for module OP 510 (resp. TresCon® P511). |
146 |
821098 |
Xylem WTW |
RB/P511 Reagent B for module OP 510 (resp. TresCon® P511). |
50 |
821099 |
Xylem WTW |
RA/P511 Reagent A for module OP 510 (resp. TresCon® P511). |
60 |
821100 |
Xylem WTW |
S/ AI - A111 Standard solution A-I (1 mg/l NH4-N), 1.5 l. |
60 |
821101 |
Xylem WTW |
S/ AII - A111 Standard solution A-II (5 mg/l NH4-N), 1.5 l. |
60 |
821102 |
Xylem WTW |
S/ BI - A111 Standard solution B-I (10 mg/l NH4-N), 1.5 l. |
60 |
821103 |
Xylem WTW |
S/ BII - A111 Standard solution B-II (50 mg/l NH4-N), 1.5 l. |
60 |
821112 |
Xylem WTW |
S/ AI - N 211 Standard solution A-I (zero standard NO3-N), 10 l. |
41.6 |
821113 |
Xylem WTW |
SSet/ N211 Set of standard solution (NO3-N) 4x 1.5 l for nitrate analyzer modules TresCon® ON 210 and OS 210, TresCon® N211/S211, TCU/N211 and S211. |
204 |
821117 |
Xylem WTW |
S/ B - N511 1.5 l standard solution B (0.4 mg/I NO2-N) for TresCon® module ON 510 (resp. TresCon® N 511 and TresCon® Uno TCU/N511). |
148 |
821121 |
Xylem WTW |
S/ BI - P211 Standard solution B-I (1.6 mg/I PO4-P) 1.5 l, for orthophosphate TresCon® module OP 210/MB 1 (resp. TresCon® P211 MB 1, TCU/P211 MB 1, OP 511, P 511). |
64 |
821122 |
Xylem WTW |
S/ BII - P211 Standard solution B-II (8 mg/I PO4-P), 1.5 l for orthophosphate TresCon® module OP 210/MB 2, TresCon® P211 MB 2 and TCU/P211 MB 2. |
64 |
821123 |
Xylem WTW |
S/ BIII - P211 Standard solution B-III (20 mg/I PO4-P), 1.5 l for orthophosphate TresCon® module OP 210/MB 3 TresCon® P211 MB 3 and TCU/P211 MB 3. |
64 |
821138 |
Xylem WTW |
RSet/A111-1 Reagent set for ammonium analyzer module OA 110 resp. TresCon® A111 and TresCon® Uno TCU/A111, 120 days operation: standards (1 mg/l, 10 mg/l)/ reagents/cleaning agents. |
499 |
821140 |
Xylem WTW |
RSet/ A111-2 Reagent set for ammonium analyzer module OA 110 resp. TresCon® A111 and TresCon® Uno TCU/A111, 120 days operation: standards (5 mg/l, 50 mg/l)/ reagents/cleaning agents. |
499 |
821143 |
Xylem WTW |
RSet/ N211 Reagent set for nitrate (SAC), for 120 days operation: standard/cleaning agent for TresCon® modules ON/OS 210, TresCon® N/S211, TCU/N211/S211. |
126 |
821156 |
Xylem WTW |
C/TCM1 1.5 l cleaning solution for nitrate/SAC, nitrite, orthophosphate, total phosphorus for analyzer module TresCon® ON 210 and OS 210, TresCon® ON 510, TresCon® OP 210, TresCon® OP 510, and analyzers TresCon® N211/S211/N511/P211/P511 and TCU/N211/S211/N511/P211. Suitable as reagent solution for ammonium for analyzer module TresCon® OA110 and analyzers TresCon® A111 and TCU/A111 |
63 |
821160 |
Xylem WTW |
C/ A111 1.5 l cleaning solution for ammonium analyzer module OA 110, TresCon® A111 and TresCon® Uno /A111; 10% citric acid. |
50 |
821163 |
Xylem WTW |
C/ N211 1.5 l cleaning solution for analyzer module nitrate TresCon® ON 210 and OS 210, TresCon® N211 /S 211 and TCU/ N211 /S 211, 0.4 % salt acid. |
66 |
821165 |
Xylem WTW |
C/N211/FE 1.5 l cleaning solution nitrite for ferrous waste water for analyzer module TresCon® ON 210 and OS 210, TresCon® N211/S211 and TCU/N211 u. S211. |
119 |
821175 |
Xylem WTW |
EL/ TC Spare lamp for photometer block. |
272 |
821195 |
Xylem WTW |
Wpack/ P211 Set of maintenance kit (fittings and spare tubes) for TresCon® phosphate analyzer module OP 210/…, TresCon® P211…and TCU/P211… |
126 |
821197 |
Xylem WTW |
Wpack/ A111 Set of maintenance kit (fittings and spare tubes) for TresCon® ammonium analyzer module OA 110, TresCon®?A111 and TresCon® Uno/A111. |
156 |
821199 |
Xylem WTW |
Wpack/ N211 Set of maintenance kit (fittings/spare tubes) for TresCon® nitrate and nitrate/SAC analyzer module ON/OS 210, TresCon® N/S 211/TCU Uno/S 211. |
122 |
821201 |
Xylem WTW |
Wpack/P511 Set of maintenance kit (fittings and spare tubes) for TresCon® total phosphorus analyzer module OP 510, TresCon® P511. |
311 |
821203 |
Xylem WTW |
Wpack/ N511 Set of maintenance kit (fittings and spare tubes) for TresCon® nitrite analyzer module, TresCon® N511 and TCU/N511. |
170 |
821210 |
Xylem WTW |
NH500/TC Ammonium electrode, incl. 3 exchange membrane heads and 50 ml electrolyte solution for module OA 110. |
906 |
821212 |
Xylem WTW |
MC/NH500/TC Exchange membrane heads for ammonium electrode, included: 3 exchange membrane caps. |
253 |
821220 |
Xylem WTW |
ELY/NH Electrolyte solution for Ammonium electrode, 50 ml. |
73 |
821939 |
Xylem WTW |
FM/PC Filter membrane module FM-Case/PC with premounted membrane. Suitable for Alyza IQ and P 700 IQ |
1439 |
821940 |
Xylem WTW |
Filter/PC Filter module for housing FM-Case/PC. Suitable for Alyza IQ and P 700 IQ |
778 |
821941 |
Xylem WTW |
FM-Case/PC Housing for filter module Filter/PC. Suitable for Alyza IQ and P 700 IQ |
967 |
821954 |
Xylem WTW |
RL 20 Permeate return line, unheated, 20 m (65 ft) |
313 |
821955 |
Xylem WTW |
RL 115-20 Permeate return line, heated, 115 VAC, 20 m (65 ft) |
3300 |
821957 |
Xylem WTW |
SL 20 Suction tube with slide, unheated, 20 m (65 ft) |
1070 |
821959 |
Xylem WTW |
SL 115-20 Suction tube with slide, heated, 115 VAC, 20 m (65 ft) |
3782 |
821960 |
Xylem WTW |
SL 230-20 Suction tube with slide, heated, 230 VAC, 20 m (65 ft) |
2227 |
821964 |
Xylem WTW |
RL 10 Permeate return line, unheated, 10 m (32 ft) |
155 |
821965 |
Xylem WTW |
RL 115-10 Permeate return line, heated, 115 VAC, 10 m (32 ft) |
1648 |
821966 |
Xylem WTW |
RL 230-10 Permeate return line, heated, 230 VAC, 10 m (32 ft) |
873 |
821968 |
Xylem WTW |
FM-B Cleaning brush for filter membrane module |
24.2 |
821969 |
Xylem WTW |
Filter-REP Replacement air filter for fan of Alyza IQ and P 700 IQ |
18.8 |
821970 |
Xylem WTW |
ST-BT Bottle top with tube |
39.4 |
821971 |
Xylem WTW |
ST 0.0 Standard solution 0.0 mg/l PO4-P (zeroing) for P 700 IQ (1.0l) |
63 |
821972 |
Xylem WTW |
Filter Set of 2 filter membranes for filter membrane module FM and module case FM-Case |
691 |
821974 |
Xylem WTW |
RL 2 Permeate return line, unheated, 2 m (6.5 ft) |
31.2 |
821975 |
Xylem WTW |
RL 115-2 Permeate return line, heated, 115 VAC, 2 m (6.5 ft) |
319 |
821976 |
Xylem WTW |
RL 230-2 Permeate return line, heated, 230 VAC, 2 m (6.5 ft) |
172 |
821977 |
Xylem WTW |
SL 10 Suction tube with slide, unheated, 10 m (33 ft) |
826 |
821978 |
Xylem WTW |
SL 5 Suction tube with slide, unheated, 5 m (16.2 ft) |
717 |
821979 |
Xylem WTW |
SL 115-10 Suction tube with slide, heated 115 VAC, 10 m (33 ft) |
2103 |
821980 |
Xylem WTW |
SL 230-10 Suction tube with slide, heated, 230 VAC, 10 m (33 ft) |
1353 |
821981 |
Xylem WTW |
SL 115-5 Suction tube with slide, heated 115 VAC, 5 m (16.2 ft) |
1293 |
821982 |
Xylem WTW |
SL 230-5 Suction tube with slide, heated, 230 VAC, 5 m (16.2 ft) |
918 |
821983 |
Xylem WTW |
FM-Adapter Adapter for horizontal mounting of filter membrane module FM |
149 |
821984 |
Xylem WTW |
Filter-CL Cleaning case for filter membranes |
66 |
821985 |
Xylem WTW |
M-EXT 1.5 Extension for attachement M 1.5. Included: Extension 1.5 m, chain, bracket |
942 |
821986 |
Xylem WTW |
M 1.5 Attachment for filtration. Included: Rail 1.5 m (4.9 ft), chain, bracket |
1180 |
821987 |
Xylem WTW |
FM Filter membrane module with premounted membrane |
1385 |
821988 |
Xylem WTW |
RM Rail mount for Alyza IQ and P 700 IQ |
794 |
821989 |
Xylem WTW |
WM Wall mount for Alyza IQ and P 700 IQ |
160 |
821990 |
Xylem WTW |
LED Replacement LED for photometer unit |
177 |
821991 |
Xylem WTW |
SM Stand mount for Alyza IQ and P 700 IQ |
1528 |
821992B |
Xylem WTW |
T SET B Set of replacement parts (fittings and spare tubes) |
279 |
821993 |
Xylem WTW |
PT Replacement pump tube |
101 |
821994 |
Xylem WTW |
PM Replacement pump motor for peristaltic pump |
433 |
821995 |
Xylem WTW |
ST 20.0 Standard solution 20.0 mg/l PO4-P for P 700 IQ (1.0 l) |
63 |
821996 |
Xylem WTW |
ST 8.0 Standard solution 8.0 mg/l PO4-P for P 700 IQ (1.0 l) |
63 |
821997 |
Xylem WTW |
ST 1.6 Standard solution 1.6 mg/l PO4-P for P 700 IQ (1.0 l) |
64 |
821998 |
Xylem WTW |
CL 1.0 Cleaning solution for P 700 IQ (1.0 l) |
88 |
821999 |
Xylem WTW |
RE 2.5 Reagent for P 700 IQ for orthophosphate measurement (2.5 l) |
123 |
822000 |
Xylem WTW |
TM Accessory for mounting of IQ Sensor Net components on Alyza IQ. Sun shield needs to be ordered separately. |
350 |
822201 |
Xylem WTW |
SH-5 Intake line with slide fo Alyza IQ, unheated, 5 m (16.4 ft) |
729 |
822202 |
Xylem WTW |
SH-10 Intake line with slide fo Alyza IQ, unheated, 10 m (32.8 ft) |
824 |
822203 |
Xylem WTW |
SH-15 Intake line with slide for Alyza IQ, unheated, 15 m (49.2 ft) |
920 |
822204 |
Xylem WTW |
SH-20 Intake line with slide fo Alyza IQ, unheated, 20 m (65.6 ft) |
1016 |
822211 |
Xylem WTW |
SH 120-5 Intake line with slide fo Alyza IQ, heated, 120 VAC, 5 m (16.4 ft) |
1316 |
822212 |
Xylem WTW |
SH 120-10 Intake line with slide fo Alyza IQ, heated, 120 VAC, 10 m (32.8 ft) |
2038 |
822213 |
Xylem WTW |
SH 120-15 Intake line with slide fo Alyza IQ, heated, 120 VAC, 15 m (49.2 ft) |
2666 |
822214 |
Xylem WTW |
SH 120-20 Intake line with slide fo Alyza IQ, heated, 120 VAC, 20 m (65.6 ft) |
3469 |
822221 |
Xylem WTW |
SH 240-5 Intake line with slide fo Alyza IQ, heated, 240 VAC, 5 m (16.4 ft) |
950 |
822222 |
Xylem WTW |
SH 240-10 Intake line with slide fo Alyza IQ, heated, 240 VAC, 10 m (32.8 ft) |
1330 |
822223 |
Xylem WTW |
SH 240-15 Intake line with slide fo Alyza IQ, heated, 240 VAC, 15 m (49.2 ft) |
1714 |
822224 |
Xylem WTW |
SH 240-20 Intake line with slide fo Alyza IQ, heated, 240 VAC, 20 m (65.6 ft) |
2092 |
822228 |
Xylem WTW |
RH-0.5 Return line, unheated, 0.5 m (1.6 ft) |
35.1 |
822229 |
Xylem WTW |
RH-1 Return line, unheated, 1 m (3.3 ft) |
37.6 |
822230 |
Xylem WTW |
RH-2 Return line, unheated, 2 m (6.6 ft) |
43.9 |
822231 |
Xylem WTW |
RH-5 Return line, unheated, 5 m (16.4 ft) |
83 |
822232 |
Xylem WTW |
RH-10 Return line, unheated, 10 m (32.8 ft) |
168 |
822233 |
Xylem WTW |
RH-15 Return line, unheated, 15 m (49.2 ft) |
251 |
822234 |
Xylem WTW |
RH-20 Return line, unheated, 2 m (65.6 ft) |
334 |
822238 |
Xylem WTW |
RH 120-0.5 Return line, heated, 120 VAC, 0.5 m (1.6 ft) |
378 |
822239 |
Xylem WTW |
RH 120-1 Return line, heated, 120 VAC, 1 m (3.2 ft) |
380 |
822240 |
Xylem WTW |
RH 120-2 Return line, heated, 120 VAC, 2 m (6.6 ft) |
388 |
822241 |
Xylem WTW |
RH 120-5 Return line, heated, 120 VAC, 5 m (16.4 ft) |
833 |
822242 |
Xylem WTW |
RH 120-10 Return line, heated, 120 VAC, 10 m (32.8 ft) |
1588 |
822243 |
Xylem WTW |
RH 120-15 Return line, heated, 120 VAC, 15 m (49.2 ft) |
2243 |
822244 |
Xylem WTW |
RH 120-20 Return line, heated, 120 VAC, 20 m (65.6 ft) |
2995 |
822248 |
Xylem WTW |
RH 240-0.5 Return line, heated, 240 VAC, 0.5 m (1.6 ft) |
232 |
822249 |
Xylem WTW |
RH 240-1 Return line, heated, 240 VAC, 1 m (3,3 ft) |
234 |
822250 |
Xylem WTW |
RH 240-2 Return line, heated, 240 VAC, 2 m (6.6 ft) |
241 |
822251 |
Xylem WTW |
RH 240-5 Return line, heated, 240 VAC, 5 m (16.4 ft) |
454 |
822252 |
Xylem WTW |
RH 240-10 Return line, heated, 240 VAC, 10 m (32.8 ft) |
840 |
822253 |
Xylem WTW |
RH 240-15 Return line, heated, 240 VAC, 15 m (49.2 ft) |
1218 |
822254 |
Xylem WTW |
RH 240-20 Return line, heated, 240 VAC, 20 m (65.6 ft) |
1631 |
825010 |
Xylem WTW |
Alyza IQ NH4-110 Ammonium analyzer Alyza IQ NH4 for the IQ Sensor Net, Measurement range 1 and 2, 1-channel w/o pump. Scope of delivery: Ammonium analyzer for indoor and outdoor use, spare parts for the first year, pre-installed 2 m SNCIQ and power cable (please order controller and reagents separately). |
15777 |
825011 |
Xylem WTW |
Alyza IQ NH4-111 Ammonium analyzer Alyza IQ NH4 for the IQ Sensor Net, Measurement range 1 and 2, 1-channel with pump. Scope of delivery: Ammonium analyzer for indoor and outdoor use, spare parts for the first year, pre-installed 2 m SNCIQ and power cable (please order controller and reagents separately). |
16015 |
825012 |
Xylem WTW |
Alyza IQ NH4-112 Ammonium analyzer Alyza IQ NH4 for the IQ Sensor Net, Measurement range 1 and 2, 2-channel with two pumps. Scope of delivery: Ammonium analyzer for indoor and outdoor use, spare parts for the first year, pre-installed 2 m SNCIQ and power cable (please order controller and reagents separately). |
16729 |
825510 |
Xylem WTW |
Alyza IQ PO4-110 Orthophosphate analyzer Alyza IQ PO4 for the IQ Sensor Net, Measurement range 1, 1-channel w/o pump. Scope of delivery: Orthophosphate analyzer for indoor and outdoor use, spare parts for the first year, pre-installed 2 m SNCIQ and power cables (please order controller and reagents separately). |
15182 |
825511 |
Xylem WTW |
Alyza IQ PO4-111 Orthophosphate analyzer Alyza IQ PO4 for the IQ Sensor Net, Measurement range 1, 1-channel with pump. Scope of delivery: Orthophosphate analyzer for indoor and outdoor use, spare parts for the first year, pre-installed 2 m SNCIQ and power cables (please order controller and reagents separately). |
15420 |
825512 |
Xylem WTW |
Alyza IQ PO4-112 Orthophosphate analyzer Alyza IQ PO4 for the IQ Sensor Net, Measurement range 1, 2-channel with 2 pumps. Scope of delivery: Orthophosphate analyzer for indoor and outdoor use, spare parts for the first year, pre-installed 2 m SNCIQ and power cables (please order controller and reagents separately). |
16135 |
825520 |
Xylem WTW |
Alyza IQ PO4-120 Orthophosphate analyzer Alyza IQ PO4 for the IQ Sensor Net, Measurement range 2, 1-channel w/o pump. Scope of delivery: Orthophosphate analyzer for indoor and outdoor use, spare parts for the first year, pre-installed 2 m SNCIQ and power cables (please order controller and reagents separately). |
15182 |
825521 |
Xylem WTW |
Alyza IQ PO4-121 Orthophosphate analyzer Alyza IQ PO4 for the IQ Sensor Net, Measurement range 2, 1-channel with pump. Scope of delivery: Orthophosphate analyzer for indoor and outdoor use, spare parts for the first year, pre-installed 2 m SNCIQ and power cables (please order controller and reagents separately). |
15420 |
825522 |
Xylem WTW |
Alyza IQ PO4-122 Orthophosphate analyzer Alyza IQ PO4 for the IQ Sensor Net, Measurement range 2, 2-channel with 2 pumps. Scope of delivery: Orthophosphate analyzer for indoor and outdoor use, spare parts for the first year, pre-installed 2 m SNCIQ and power cables (please order controller and reagents separately). |
16135 |
827000 |
Xylem WTW |
MPV-1 Multiport valve for Alyza IQ |
357 |
827100 |
Xylem WTW |
TubingSet NH4 Set Tubings NH4 with sample contact |
90 |
827101 |
Xylem WTW |
TubingSet PO4 Set Tubings PO4 with sample contact |
90 |
827170 |
Xylem WTW |
Syringe Pump Set Spareparts syringe pump |
295 |
827180 |
Xylem WTW |
Overflow Vessel Overflow vessel incl. overflow tubing |
301 |
827185 |
Xylem WTW |
Filtration Pump Filtration pump for Alyza IQ incl. connecting tube |
449 |
827186 |
Xylem WTW |
Check valve Check valve Alyza IQ, for retrofitting at a head > 5 m |
60 |
827187 |
Xylem WTW |
WF Set Waste funnel set for the separate collection of reagent containing waste |
64 |
827188 |
Xylem WTW |
PurCon ACS Adapter for sample transportation from PurCon® to Alyza IQ |
188 |
827190 |
Xylem WTW |
Conversion kit PO4 MB1 Conversion kit Alyza IQ PO4 MB2 to MB1 |
627 |
827191 |
Xylem WTW |
Conversion kit PO4 MB2 Conversion kit Alyza IQ PO4 MB1 to MB2 |
1350 |
827500 |
Xylem WTW |
R-NH4/1-1A Reagent 1A for NH4 measurement range 1 (0.02 … 5.00 mg/L NH4-N) |
81 |
827501 |
Xylem WTW |
R-NH4/1-1B Reagent 1B for NH4 measurement range 1 (0.02 … 5.00 mg/L NH4-N) |
81 |
827502 |
Xylem WTW |
R-NH4/1-1C Reagent 1C for NH4 measurement range 1 (0.02 … 5.00 mg/L NH4-N) |
81 |
827503 |
Xylem WTW |
R-NH4/1-2A Reagent 2A for NH4 measurement range 1 (0.10 … 20.00 mg/L NH4-N) |
81 |
827504 |
Xylem WTW |
R-NH4/1-2B Reagent 2B for NH4 measurement range 1 (0.10 … 20.00 mg/L NH4-N) |
81 |
827505 |
Xylem WTW |
R-NH4/1-2C Reagent 2C for NH4 measurement range 1 (0.10 … 20.00 mg/L NH4-N) |
81 |
827510 |
Xylem WTW |
S-NH4/1-0.0 Standard solution 0.0 mg/L NH4-N Alyza IQ |
79 |
827511 |
Xylem WTW |
S-NH4/1-1.0 Standard solution 1.0 mg/L NH4-N Alyza IQ |
79 |
827512 |
Xylem WTW |
S-NH4/1-4.0 Standard solution 4.0 mg/L NH4-N Alyza IQ |
79 |
827513 |
Xylem WTW |
S-NH4/1-16.0 Standard solution 16.0 mg/L NH4-N Alyza IQ |
79 |
827518 |
Xylem WTW |
C-NH4/1-1 Cleaning solution 1 Alyza IQ NH4 |
79 |
827519 |
Xylem WTW |
C-NH4/1-2 Cleaning solution 2 Alyza IQ NH4 |
79 |
827520 |
Xylem WTW |
R-PO4/1-1A Reagent 1A for PO4 measurement range 1 (0.02 … 15.00 mg/L PO4-P) Alyza IQ |
64 |
827521 |
Xylem WTW |
R-PO4/1-1B Reagent 1B for PO4 measurement range 1 (0.02 … 15.00 mg/L PO4-P) Alyza IQ |
64 |
827522 |
Xylem WTW |
R-PO4/1-2A Reagent 2A for PO4 measurement range 2 (0.2 … 50.0 mg/L PO4-P) Alyza IQ |
64 |
827523 |
Xylem WTW |
R-PO4/1-2B Reagent 2B for PO4 measurement range 2 (0.2 … 50.0 mg/L PO4-P) Alyza IQ |
64 |
827526 |
Xylem WTW |
S-PO4/1-0.0 Standard solution 0.0 mg/l PO4-P Alyza IQ |
59 |
827527 |
Xylem WTW |
S-PO4/1-1.0 Standard solution 1.0 mg/l PO4-P Alyza IQ |
59 |
827528 |
Xylem WTW |
S-PO4/1-10.0 Standard solution 10.0 mg/l PO4-P Alyza IQ |
59 |
827529 |
Xylem WTW |
S-PO4/1-40.0 Standard solution 40.0 mg/l PO4-P Alyza IQ |
59 |
827533 |
Xylem WTW |
C-PO4/1-1 Cleaning solution Alyza IQ PO4 |
59 |
827540 |
Xylem WTW |
R-Set NH4/1-1 Reagent set NH4 measurement range 1 (0.02 … 5.00 mg/L NH4-N) consisting of reagent 1A, 1B, 1C for analyzer Alyza IQ |
236 |
827541 |
Xylem WTW |
R-Set NH4/1-2 Reagent set NH4 measurement range 2 (0.10 … 20.00 mg/L NH4-N) consisting of reagent 2A, 2B, 2C for analyzer Alyza IQ |
236 |
827545 |
Xylem WTW |
SC-Set NH4/1-1_0/1 Set consisting of cleaning solutions and standard solutions 0.0/1.0 mg/l NH4-N for analyzer Alyza IQ NH4 |
235 |
827546 |
Xylem WTW |
SC-Set NH4/1-1_0/4 Set consisting of cleaning solutions and standard solutions 0.0/4.0 mg/l NH4-N for analyzer Alyza IQ NH4 |
235 |
827547 |
Xylem WTW |
SC-Set NH4/1-2_0/16 Set consisting of cleaning solution and standard solutions 0.0/16.0 mg/l NH4-N for analyzer Alyza IQ NH4 |
235 |
827550 |
Xylem WTW |
R-Set PO4/1-1 Reagent set PO4 measurement range 1 (0.02 … 15.00 mg/L PO4-P) consisting of reagent 1A, 1B for analyzer Alyza IQ |
127 |
827551 |
Xylem WTW |
R-Set PO4/1-2 Reagent set for PO4 measurement range 2 (0.2 … 50.0 mg/L PO4-P) consisting of reagent 2A, 2B for analyzer Alyza IQ |
127 |
827555 |
Xylem WTW |
SC-Set PO4/1-1_0/1 Set consisting of cleaning solution and standard solutions 0.0/1.0 mg/l PO4-P for analyzer Alyza IQ PO4 |
171 |
827556 |
Xylem WTW |
SC-Set PO4/1-1_0/10 Set consisting of cleaning solution and standard solutions 0.0/10.0 mg/l PO4-P for analyzer Alyza IQ PO4 |
171 |
827557 |
Xylem WTW |
SC-Set PO4/1-2_10/40 Set consisting of cleaning solution and standard solutions 0.0/40.0 mg/l PO4-P for analyzer Alyza IQ PO4 |
171 |
830860 |
Xylem WTW |
VB 105 Overflow vessel with continuous sample flow for analyzer. |
1171 |
850007 |
Xylem WTW |
P105 Submersible pump without cutting blade for PurCon®, PF 105 or FPB. |
1210 |
850010 |
Xylem WTW |
FGT 615-2 = P102/1 Low-power submersible pump with cutting blade for supplying wastewater from the aeration stage of wastewater treatment plants. |
2278 |
850019 |
Xylem WTW |
PZN 30 Fabric tubing for pumps P101/P102/P105 (30 m) |
640 |
850110 |
Xylem WTW |
BS-P102 Mounting set for submersible pumps P 101, P102/1 and P 105 (V4A stainless steel chain (length 5 m/16.2 ft) and 2 stainless steel shackle). |
288 |
850115 |
Xylem WTW |
ADA/PS GEKA adapter for connecting pumps P105, P101 and P102/1 with hose PZ105. |
66 |
900107 |
Xylem WTW |
CH Cleaning head for on-line sensors with 40 mm diameter. Supplied with 15 m (49 ft) compressed air tube. |
545 |
900111 |
Xylem WTW |
CH/Epack Spare part set for cleaning head |
144 |
902888 |
Xylem WTW |
ADA/D-SUB D-SUB connection for Profibus and Modbus connections for the IQ 2020 and 282/284 systems. |
132 |
902890 |
Xylem WTW |
ADA/E Connector for the Ethernet interface (RJ45) on controllers of System 282/284. Ensures protection IP67 when Ethernet cable is connected outdoor. |
21.4 |