Description: spectral UV sensor (60 mm) for measurement of Nitrite, Nitrate, CODtotal, CODsoluble, TOC, BOD, DOC, SACtotal, SAC soluble, and UVT254 in the effluent of municipal waste water treatment plants, with integra-ted ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings, without connection cable (SACIQ order separately).
Measuring method:  spectral measurement in the UV Range (200 – 390 nm)
Measuring gap: 1 mm
Range / Resolution:  Effluent
NO3+: 
0.0 ÷ 250.0 mg/l / 0.1 mg/l
NO3-N:
 
0.00 ÷ 50.00 mg/l / 0.01 mg/l
NO2+:   
0.0 ÷ 100.0 mg/l / 0.1 mg/l
NO2-N: 
0.00 ÷ 25.00 mg/l / 0.01 mg/l
COD
 total: 0 ÷ 800.0 mg/l  / 1mg/l
COD 
dissolv: 0 ÷ 800.0 mg/l  / 1mg/l
TOC:
 0.0 ÷ 500.0 mg/l  / 1mg/l
DOC: 
0.0 ÷ 500.0 mg/l  / 1mg/l
BOD: 
0.0 ÷ 500.0 mg/l  / 1mg/l
SAC
254 total:  0.0 ÷ 600.0 1/m / 1 1/m
UVT
254 total: 0.0 ÷ 100.0% / 0.1%
Accuracy:  NO3-N, NO2-N: ±3% of measured value ± 0.5 mg/l
Carbon parameters: ± 5 % of measured value ± 2.5 mg/l
SAC: ± 0.5 % of measured value ± 0.4 SAK
UVT: < 10 % UVT ± 1 % UVT of measured value; > 10 % UVT ± 0.1 % UVT of measured value
Flow rate:  ≤ 3 m/s
Pressure:
1bar
Electrical connection: 
2-wire shield cable with quick fastener to sensor (SACIQ network)
Electromagnetic compatibility:
EN 61326, Class B, FCC Class A;  Intended for indispensable operation
Protection class: 

IP68

Material: 

Housing: Titan Grade 2,
PEEK Window: Sapphire glass 

Weight:

4 kg (8.82 lb)

Warranty: 

2 years

Maintenance and accessories  

Sensor connection cable

Mounting accessories for basins and open channels